Air Conditioner Choking Problem Ac Not Cooling Repairing Ac Suction Pressure Very Bad (Urdu)
HTML-код
- Опубликовано: 18 окт 2024
- This video is about the Air Conditioner Choking Problem Ac Not Cooling Repairing Ac Suction Pressure Very Bad complete guide in Urdu/Hindi language
#Choking
#Airconditioner
Dhanyavad bhai ! tushi rabb da vasta bahut hi changa jankari knowledge diya hai,Thanku ji,
Thanks #ajengineering
Very informative video this one is thanks dear friend
Thank you
Bhot hi ache se bataye ho ap bro
Very nice video
Very nice information sir ji
Thanks
explained vrey nicely. thanks.
Thank you
MashaSllah bohy hoob baho g
Thanks #ajengineering
Allah tallah aap ko or jiyada bulandion par le jaye Aameen
Thanks
Bahot aachi hi vedio sir
❤❤❤❤❤❤❤❤ mashallah zabardast bhaijaan but aap ne campressor cheng kiya to aapne cheng karte wakt fleshing nhi kiya tha kya
bilkul flashing Hota Hai system #ajengineering
@@Ajengineering phir kyo ye chok hogya ye sistem sir
Very Nice sir.
Thanks for your excellent video. From where did oil reach suction line? Was there any leakage?
Good information
Bhai... Mera 1.5 ton whirlpool ac hai. Recently mene gas feeling kiya hai. Par gas feeling karne ke Baad abhi ac chalane ke dauran 6-7 mins me cut off ho ja raha hai. Kya ye sahi hai normal hai ya koi filter ya capillary ka issue hai?
thank you sir .....very very good information....
Welcome bro
Excellent . 👍
Thanks
Nice work thanks for video God bless you
Thanks
If any one give complaint on this channel he will stay in Jail.......As per law there is no permission to expose GWP gases.he should recover the gas
Very nice brother bohat wazahat sey ap ney video bnai hey video ki samaj bhi ati hey video dekh k ap ka channel subscribe karney ko dil karta hey.
Thanks bro
Wha R141 use krte h zyada flash k liye iska kya funda hai btayega
bhai jan kia hal hy.
bhai mera one ton ka AC hy us ka gas pressure 50 hy.
jab chalata hy to load 4 amper leta hy thek 5mint bad load 1.7 ho jata hy or gauge par 120psi pressure show hota hy plz rehnami karen
Vai apka video acca he o genarel 5ton ac me leck tha leck solve kornaka bad ice goma jaya he iska rizen kaya he
Bhai eske indoor ki PCB AUR wairing ki video banaeeye aap
Good job
Nice video bro
Thanks #ajengineering
Sir kon si wali line ka allenkey band karni hai uh to bataye nahi aur es ac main koun si gas hai sir aur sir esmain jo gas thi uska kiya kiye
Nice Bayya suction line se oil aatha haina pressure dalnekebad kidarse aatha hy bayya
very very nice video sir
Thanks bro
Oil tu kafi bahar nikal gya ha tu kya es sy phr compressor k parts par tu koi farq ni pary ga ?
Humra ac kbi kbi bht achi cooling krta h ar kbi sirf chlta ha Thori dyr k liye ar PHR ada ganta chlta hi nai ha PHR apni mrzi sy cooling krta h AP bta skty hai k Kya problem ho skti h
Meneh 1 week pehele split ac gas leakage tik karwakeh gas bar diya tha, abhi cooling hi nehi horaha heh 1 week bhad or pressure bhi 140 dikha raha heh gauge me. Kya problem honsakta heh?
Sir. Ap 22 gas se indoor unit + outdoor unit ko flas kar rahe ho . . But kyaa ham Air presor se bhi sem flasing kar sakte he . Koi problem he kyaa agar hum Air flash kare to .. ?
Good
Thanks
Bhai hmko pahle aap ye batao ki 3 phase ka central ac hai aur jab hm chalu kerte hai tab ac cooling nhi ker raha hai aur gas bhi dal diye phir bhi ice aa raha hai aur suction presure bhi nhi badh raha vacum me ja raha hai mai filter ko bhi change ker diya outdoor indoor dono ko falsh bhi ker diya compressor bhi change ker diya lekin phir bhi ice aa raha hai aur gas suction line me nhi chadh raha hai kya kya problem hai plz reply my answer
Ac fridge washing machine repair ka kam sikh ne me kitana time lagta he pelese give me answer
sir maine abhi new ac liya hai lg 1.5 ton R32........maine usme additional copper pipe add karwaya hai but gas extra dali.hi nahi technician ne........cooling ho rhi hai but tym lag rha hai bahot jada.........toh sir mujhe top karana hai toh.......vaccuming jaruri hai kya?????
Puri gas nikal do aur dubara se new gas charge kar do #ajengineering
@@Ajengineering jo technician aaya tha ac fit karne usne indoor unit ka drain pipe fit nhi kiya tha n uske sath jo helper aaya tha usne outdoor unit se gas open kar diya tha toh technician bol rha tha mujhe darr lag rha hai air na ban jaye....aisa kyo bol rha tha wo
Usne AC ki vacuum Nahin Ki Ho gi ap ke AC cooling Sahi kar raha Hai to no problem #ajengineering
Aj engineering copper pipe extra dala hai but extra gas nahi dali thi ....
and cooling mai bahot tym lag rha hai 18 pe toh jaa hi nahi rha room temperature ab agar gas top up kare toh kya vaccuming karwana chahiye ki nahi???
As salawaly kum Janab Kay haal hai
Bhai aap DUBAI mai hai
Soudi Arbria
Thank you brother
Welcome
Thanks ji
Welcome #ajengineering
Bhai aghar compressor mein lra Chang laga dain ya ya big laga dain to Kia Kia masks as satha hai
Compressor heat up Ho ga Kam Nahin Kare ga #ajengineering
Good job 👍
Thanks #ajengineering
Bhai Jan agr app isko running ma suction valve off krky gauge on e rakhty to best flashing ho jani thi aur cylinder gas b bach jani thi apki
Correct sir
Mast bhayi
Thanks bro
Sir ye batao agar AC 3 yrs used nhi hua hain mera but ab won AC chal nhi raha hai kya fault ho sakta hai usme bataiye pls
Nice video sr
Thanks
Awsm video for new wrkers
❤
Bhaiya capilary chg video banao plss
Ya hia video
ruclips.net/video/7bvx4xj7WaA/видео.html
Nys Sir
Ek tecnation ne 2 dafa gas chrg ki hai lkn dono dafa easa hi howa ab wo bol rha hai k outer mai masla hai change hoga kion k is ka candancer silver ka hai apni tor pe us ne leakage trac karne ki کوشش ki hai
Good 👍
Thank you sir
❤
Nice
Thanks #ajengineering
nice
Thanks
Mast video
👍
What abt window AC usmein blockage kaise padhein .ampere kyaa transformer ke sath lag taar par dekhtey hain???LG ke technician kuch Ajeeb kar rahey they.
Ek ac m gase dal dya hu pura but back pressure nhi badh raha hai bilkul 0 hai or amp 3 4 le raha hai or 5 minit bad compresser band ho jata hai kya reason hai bataye plz r22 gase hai
Indoor-outdoor ko nitrogen se flash karo filter change kar do OK ho Jay ga #ajengineering
Capillary setting baato Bhai 1.5 ton ac kaaa
Cappilary change karnay Kay badh my gas charging Kara hu guage may Hy value dekhara Bhai choking problem ko Kyu solve karna Bhai koi jaldi baatav bhaii 🙏🙏🙏🙏🙏
Assalam-o-Alaikum!
Sir…Hamara split AC ki kuch problems hain…Kindly guide
1.
Cooling bohat kam kr raha hai
2.
Pani bohat dair baad phenk raha hai aur who bhi
bohat kam
3.
1 ya 2 hours k liye cooling krta hai phir normal
hawa phenkna shuru kr deta hai jab tak hum isko off kr k dobara on nhi krty.
4.
Kabhi kabhi to dobara on krny pr bhi cooling
start nhi krta bs normal air phenkta hai.
Please guide us hum kia karain…Gas bhi refill krwai hai 1 week pehlay…..Thanks
Sir a sigal fas AAA ke dabal fas aa g .. plz plz reply kro g plz sir
Voltage check karo?
Bhai lg ka 1.5 ton split AC hai AUR refrigerant R22 hai magar jab me AC on karta hoo AUR heating mode PE rhakta hoo too to us ka back pressure 200 psi ho jata hai AUR off Karne par 65 psi rheta hai AUR 5 AMP LETA HAI IS PROBLEM KO THEEK KESE KARE
bhai jaan ap air condition ko cooling Mode Pe Chala ke check karo kitne ampere leta hai aur cooling Kaise karta hai
heating Mod Pe Ac ka running process zyada hai Hota Hai
Sir yeh Jo aisi hai ESI AC ka wiring video banao please
Ok video upload karun ga
Thanks
@@Ajengineering sab Shokriya Janb Zaror karna
Bhai aap hmko single fan dactable AC outdoor Ka wairing per ek Pura video banaeeye aap plz
Yes Good requirement
Ok Bro jaldi He video upload karun ga
Thanks
Welcome sir
Head your email address
sir ye kitne ton ka outdoor he jo 24se 27 a hne chye??mjhe to 4 ton ka lgra he jiske a 5 hne chye 24 kese ??
5 tan
Hello bhai kya naitrojen se flash kar sakta hu
Yas
Thanks thanks thanks
Welcome
سر ایک ویڈیو انورٹر اے سی پر بھی بنائیں
Sir make a video on SPPR and lock out relay plz
Pls more sir
Thanks
3phsa me package unit me subzero ka wiring kaise kare videos dikhaye sir
subzero nhi Hota hia Package Ac Ma thermostat Hota hia #AJEngineering
Sir agar choking hogi to kya suction pipe main ac run pe ice aayegi outdoor ke pass ppipe main olz bataye
Nahi
Mere bhai r22 550rs kilo h sirf flush karne k liye isko istemal karna bohot mehnga padega uper se nature k liye bhi harmfull h aise gas udhana🤔🤔🤔🤨🤨🤨
Haa
Thanks do you thanks giving today or in November and do you have christmas in dec
Sir, share my video with my friends
Thank u sir..
Thanks #ajengineering
System ko flushing karne k liye sab se best R11 hota hai
Yas Thanks #ajengineering
Sir same problem hai ek split ac me standing pressure 130psi hai aur running me 30 hai aur ye single phase ac hai toh Mai isko flush karun ya capillary change karun pls reply
bhai r 22 running m 65 psi show krna chahiye agar nahi kr raha to topup kro gas wese r22 band ho rahi uske jage r417 arahi hai to r417 gas charge krne ke liye apko r22 ko vaccum krna hoga 0 se niche tak phir r417 charge krni hogi 65 psi
batter ya hai k ap os ko nitrogen se flash karo nitrogen se flash karne ke liye ap ke pas double step regulator Aana chahie
I have this same problem,then I change filter and capalary, after this flush with N2, system Ko tab tak flush karo jab tak evaporater and condenser line clear na ho jaye,vacuum the system and charge R22 slowly slowly
@@ParminderSingh-lx4yk thans
Bhai 18000 BTU m b dono lagi hoti hain
Ya kitny ton ha
Am waiting
English language please thanks you
Bhai mere pas sigal stage vaccum pump he tho r32 and r410 gas charing me chalega kya bhai kuch log mana kartehe tho kya bhai
Sir this unit capillary zize sir
Maybe not all but as many as posable i like installing electrical wiring the best
You also watch your video in the head You also make a very good video
Brother mere pass Mitsubishi Mr Slim R22 split unit laga hua hai recently us me indoor me se evaporater coil me se jese pani jata ha pipes me wesi awaz aney shuru ho jati ha on hone ke 5-10 mint bad and phr cooling band. Jese koi cheez gas ko block kar dete ha and indoor me se sur sur ki awaz ati ha coil me se
Indoor outdoor ko gas se flash karo problem solve ho jay ge #ajengineering
Aj engineering aik bar flush kiya hai sir g indoor outdoor donu magar phr problem start hogya ha. Ampere b kam kr jata ha aur suction pressure b kam ho jata hai.
System Mein blockage ho sakti hai proper check karo #ajengineering
Compressor B check karo
5 ton Ac Hu tu eska 1 Phase meh
Current Amp r 6 hoga but
24 Amp r keu? Reply karu brother ♥
1 ton AC 5 6 ampere 5 ton AC
5 ton AC 25 amps
@@Ajengineering bro 5 ton Ac howa to keya howa 3 phase Ac Meh 1 phase meh maximum 9/10 Amp r hoga load meh but Apne bola 24 why? Reply
Single phase 5 ton 220 compressor Mein Ek phase Mein 24 ampere ho gay
N L =Yahan per N 24 Amps
L 24 Amps
Compressor ka size Bhi Bada Hai Aur winding Bhi Jyada Hai Amps Jyada ho gay #ajengineering
Three phase 5Ton AC per L1 9 Amps L2 9 Amps L3 9 Amps ho gay
@@Ajengineering 5 ton Ac meh bhi single phase hoti hae plz ake 5 ton Single phase kah Waring kih vidieo upload kare brother ♥
Bhai r32 and r410 me vaccum dusare fridge ke compressor se flashing and vacuming karsakatehe kya
Sir mere ac me temperature 26 pe rakhu ya 22 pe rakhu but cooling ek jesa hi ho raha he kuch farak hi nahi he. Aur mera compressor continue on rehta he on off nahi hota he aesa kyu.??
AC ki gas check karo #ajengineering
@@Ajengineering gas to thik hi lag rahi he muje coz mene wo outdoor vali pipe check ki he moti vali pipe child he aur patli vali thodi kam child he
Ap ne AC repair karvaya tha
First of all this guy is spoiling the environment by flushing r-22 gas we have to use only nitrogen and flush the system pls don't give wrong information and confuse customer
Yes
Good w
Thanks
Assalamo alaiqum bhai
W/salam
Mandatory to recover the Gwp gases which are harmful to nature
Ye sun kum rahey hain dilzyada baantnein mein lagey hain
Sir ampere note kaise karein?mujhe LG ke technician chalaki kartey dikhey unhoney ampere metre transform.meun judhti ..Lekin AC ki taar mein lagaya..wahan to kabhi lagtey nahin.dekja.exactly gas kitni hai Kahan attach kartey hain usko naapne ke liye .window AC mein
after vacuum, why you open the high side pressure knob?
Ok Thanks
Bhi hafta pehlay same problem tha
Sir nitrogen se flush kyu nahi kiya?
Nitrogen available nahi thi bro
Wow
❤
हमारे पास गोदरेज डेढ़ टन की यूनिट है उसमें जो बैक प्रेशर है वो 70 से 75 है और स्टैंड प्रेशर 165 से 170 है पर कुलिंग वैसी नही है जैसी होनी चाहिए जबकि डेढ़ टन के हिसाब से कमरा भी छोटा है और हाँ कूलिंग मोड में जब AC को चलाते है तो कंप्रेशर 3 मिनट चलता है और 3 ही मिनट बन्द रहता है जबकि ड्राई मोड में चलाते है तो कम्प्रेशर ठीक से चलता है और कूलिंग भी ठीक होती है और टेंपरेचर 9 से 6 तक अपने आप सेट हो जाता है ड्राई मोड में हवा बोहत धीरे धीरे आती है जबकि इनडोर में जो सेंसर होतेहै उनको भी चेक कर लिया है समझ नही आरा है कि क्या प्रॉब्लम है
इतना कुछ लिखा और तुमने रिप्लाय क्या किया जो पूछा अगर उसके बारे में बताते तो ज्यादा अच्छा होता
1.5 ton ac me liquid line pr vslve ni laga hota h to us condition me kaise discharge pressure chek krenge
Condencer me capillary se pehlay kisi jaga charging bulf laga kar
Outdoor ke andar check karo valve ho ga #ajengineering
Bhai sahab coaching create 11 use kijiye Achcha result hai Nahin to r22 ke sath CTC use kijiye
Thanks #ajengineering
Kon c gas hy Brother is me
R22 gas