So once it has completed setup, what is a considered a "normal" display on the outside unit LCD? Mine scrolls through the addresses over and over again, but seems to be working fine. The only concern I have is that the target temp is often overshot in one room when the other two larger rooms are still running.
I'm having a communication error with one indoor unit and the fjm here. Is there a way to re address the system like on startup? I checked the continuity of the wires and receimped the termination but still getting the error.
I Started a pipe check with no refrigerant in the lines, would that mess up the compressor or anything? Getting a pipe check error code . Did a reset of outdoor unit. Checked pipes, found one minor kink that I rounded out. Still getting error code
Hello.. I have a challenge with One FJM system with 3 indoor units one of the units doesn't heat effectively and at some point cuts the fan [during heating mode]
Thank you so much, this is so much clearer than the manual
You're doing God's work...currently out of town, boss abandoned me and said good luck. Thanks to you I can have some semblance of hope.
So once it has completed setup, what is a considered a "normal" display on the outside unit LCD? Mine scrolls through the addresses over and over again, but seems to be working fine. The only concern I have is that the target temp is often overshot in one room when the other two larger rooms are still running.
Should i turn the indoor units ON before i do the auto pairing?
I'm having a communication error with one indoor unit and the fjm here. Is there a way to re address the system like on startup? I checked the continuity of the wires and receimped the termination but still getting the error.
Do you have a suggestion if the k1 button doesn't do anything
We are having a problem with the modbus cards and getting the outdoor units to talk to our BMS system
So much better than Samsung tech support
I Started a pipe check with no refrigerant in the lines, would that mess up the compressor or anything? Getting a pipe check error code . Did a reset of outdoor unit. Checked pipes, found one minor kink that I rounded out. Still getting error code
Definitely have it vacuumed and charged due
How long does K1 take to kick
Thank you top top
Hola amigos , debo agregar una unidad evaporadora al sistema , cómo es el procedimiento!
You have saved me, the instructions are junk, many thanks 🎉
Hello.. I have a challenge with One FJM system with 3 indoor units one of the units doesn't heat effectively and at some point cuts the fan [during heating mode]
What model is your s? On cool mode with all 3 indoor unit on what is the max frequency of te compressor! Thanks
what did you find out the issue was causing this?
To tentando configurar o meu mais a Seg maquina não daí o f2
Quantas unidades Evaporador
Solution E2 02?
Samsung vrf ac how to set auto address and test mode
2 time k2 presh
My Samsung is showing U.P blinking. Dont know what that means
idk what it means but it pisses me off
My unit got to that section at 1:32 but it displayed the T1oT and didn’t switch to flash the addresses. Any help?
It happened for me as well. I just pushed the k1 button again and it started doing it.