How to make Low Voltage distribution single line drawing (SLD )and calculation (11KV Substation)

Поделиться
HTML-код
  • Опубликовано: 24 мар 2021
  • How to make low voltage distribution single line diagram in electrical substation and how to calculate each component rating like breaker,fuse,switchgear and other protection devices are explained in this video. so watch the video completely for your understanding
    #LVDB #lowvoltage #substation #equipmentsizing
    1.How to calculate cable sizing for electrical load
    • Transformer sizing for...
    2.How to read Single line diagram of substation
    • How to read 11KV switc...
    3. How to size transformer in substation
    • Transformer sizing for...
    4. How to size Motor control center in substation
    • Electrical Switch Gear...

Комментарии • 32

  • @sdssds3933
    @sdssds3933 Год назад +1

    Excellent teacher. Thank you so much

  • @abdirisakabdulkadir9293
    @abdirisakabdulkadir9293 3 года назад

    U r great man bro, ur videos make easy for stones. Thank u 👍👍.
    God bless you

  • @ikpalian4413
    @ikpalian4413 Год назад

    Electrical master 🙌 I love u so much u re good for all

  • @himanshu5948
    @himanshu5948 2 года назад +7

    Why not choose a SC rating of 50 kA for 1 second or 63 kA for 1 second? If you choose 80 kA for 1 second, it will be very expensive to manufacture.

  • @gurushankars9046
    @gurushankars9046 2 года назад

    Superb sir keep going keep helping us

  • @GopiRavi24
    @GopiRavi24 Год назад

    Thank you sir for upload this useful video 🙏

  • @user-hc8ge7jy8z
    @user-hc8ge7jy8z 10 месяцев назад

    Good job sir!

  • @MaheshBaburajapalayam
    @MaheshBaburajapalayam Год назад

    Thanks very much

  • @saravanans4471
    @saravanans4471 8 месяцев назад

    Great thanks sir

  • @v.jbalan9547
    @v.jbalan9547 3 года назад +1

    Your all videos very useful please make it one video for underground cable testing

    • @electricalmastar
      @electricalmastar  3 года назад +1

      Thank you so much Mr. V.j.balan, and i will make separate video for your request very soon
      Keep support our channel
      Thank you

    • @v.jbalan9547
      @v.jbalan9547 3 года назад

      @@electricalmastar😍😍

  • @gobinathgobi2299
    @gobinathgobi2299 3 года назад

    Nice bro

  • @amalikmalik1724
    @amalikmalik1724 Год назад +2

    As technically if the busbar Isc = 41.9kA, 50 / 63 kA for 1 sec will be ok, & also please check the O/G breaker sizes shall be more than or equal to 41.9kA but shall not be less than 41.9kA, please check..

  • @hariharan4022
    @hariharan4022 3 года назад +3

    Dear sir,
    Kindly Provide me the IEC standard for this calculation.
    Regards
    Hariharan

  • @md.gufranansari9672
    @md.gufranansari9672 3 года назад

    Great Dear. You have explained nice. Which code you have followed for this all design. Please tell me.

  • @ranjan1436
    @ranjan1436 3 года назад

    to calculate motor FLC, motor efficiency also has to be considered?

  • @arularasu3060
    @arularasu3060 3 года назад +1

    Dear sir,
    Kindly do same topic for 33kv/11kv 2×10MVA. Tq sir

  • @arafatbaunto4068
    @arafatbaunto4068 2 года назад +1

    Can you share your IEC reference

  • @manmohandhir9117
    @manmohandhir9117 2 года назад +1

    I think that u should have used nominal voltage of 415 volts as per IE rules & made
    calculations accordingly

  • @ikpalian4413
    @ikpalian4413 Год назад +1

    But in this calculation u did not consider voltage drop and amp acuity of the cable to mcc

  • @warist20khan12
    @warist20khan12 11 месяцев назад

    Sir the apparnt power onley used for generator and sir reactive power used for transformer sir please understand me

  • @hpvide
    @hpvide 10 месяцев назад

    why inrush current not consider in LV circuit breaker

  • @Ozzy2341
    @Ozzy2341 3 года назад

    Do you teach online ?

  • @mesmericgirl7245
    @mesmericgirl7245 2 года назад

    How to find impedance of the transformer

  • @syedjameelahmed66
    @syedjameelahmed66 6 месяцев назад

    While selecting circuit breaker, Every C.B comes with starting current and short circuit current capacity. selection of 630 A looks wrong. Please correct me if I am wrong.

  • @johnsaidashaik8134
    @johnsaidashaik8134 Год назад

    How to got 105 A

  • @jithinthomas5552
    @jithinthomas5552 2 года назад

    Hmm... IEC "rules"?
    Never knew IEC imposed any rules.
    If you're mentioning IEC standards, please provide the standard's reference number also.

  • @ethinkgroup8492
    @ethinkgroup8492 3 года назад +1

    Hi, your explanation is so good. We are a startup looking forward to benefit engineering students with your expertise. Can you share your email so I can send details. Thank you

  • @manmohandhir9117
    @manmohandhir9117 2 года назад +1

    I think that u should have used nominal voltage of 415 volts as per IE rules & made
    calculations accordingly