NEMA 14-50 Buying Guide for Tesla EV Charger

Поделиться
HTML-код
  • Опубликовано: 2 дек 2024

Комментарии • 511

  • @handydadtv
    @handydadtv  4 года назад +18

    💰 LOOKING FOR A CHEAPER ALTERNATIVE? 💰
    The Hubbell 14-50 has skyrocketed in price since this video was made. There is a cheaper Hubbell outlet that provides the same speed of charge. Watch this before deciding 👉🏻 ruclips.net/video/XNOnVxI0tvk/видео.html
    ***NOTE: Hubbell supports _copper_ wiring only! Incorrectly shown as AL-CU in the video.

    • @jmlastname4412
      @jmlastname4412 2 года назад

      Aluminum wire should NEVER be used whether the device is marked compatible or not. ESPECIALLY on a charger.

    • @kungfoochicken08
      @kungfoochicken08 Месяц назад +1

      @@jmlastname4412Properly sized aluminum wiring is actually far better for larger feeder wire. 4 gauge aluminum runs much cooler than 6 gauge copper and it’s a bit cheaper. Just want to make sure your breaker and receptacle are rated for aluminum wiring. Mobile home feeder wire is 2 gauge aluminum, roughly the same cost as 6/3 and it will never give you issues.

  • @kriley9386
    @kriley9386 3 года назад +16

    I used a Leviton surface mount fixture. Surface mount is much easier for concrete block walls! It was $10.73, made in USA, and the wires are clamped flat, not screw-on-conductor. It looks very professional in my garage and functions perfectly.

    • @handydadtv
      @handydadtv  3 года назад +1

      Thanks for letting us know

  • @pjtemplin
    @pjtemplin 3 года назад +9

    One data point that does ease the load on the 50A outlet: the current Gen2 UMC only supports 32A charge current, so the outlet isn’t loaded to the 40A you might expect. Tesla does sell a Corded Mobile Charger that has a hard-wired NEMA 14-50 plug (not changeable) that supports 40A charging. I’d still choose the Hubbell outlet for it though.

  • @johnpoldo8817
    @johnpoldo8817 4 года назад +43

    There’s a big difference in price between the Hubble and all the others. Primary difference is Hubble is designed for numerous insertions and removals, while the others are designed for only a few similar to a dryer or range. Its wire clamps are also much better but you must tighten them securely. It’s wise to periodically feel the plug for heat after 1-2 hour’s use. After 6 months use, mine felt warm and I discovered one screw terminal looser than the other. Tightening the offender solved it.

    • @inediblenut
      @inediblenut 3 года назад +1

      Great tip! I had a similar problem with a dryer plug I installed, and the heat eventually destroyed it.

    • @URBANENGINEER
      @URBANENGINEER 3 года назад +3

      It’s really important to do the “wiggle test” while tightening the plug to spec. They slowly vibrate themselves loose unless you do this.

    • @parkershaw8529
      @parkershaw8529 3 года назад

      Exactly, the installation makes a much bigger difference than the receptacles themselves, Especially if you don't plug and unplug all the time.
      I feel comfortable to use the 2nd one and install it carefully. IMHO, I would rather spend more money to get a bigger box.

    • @daijoubu4529
      @daijoubu4529 2 года назад

      Residential vs spec/commercial/hospital grade

    • @johnpoldo8817
      @johnpoldo8817 2 года назад +3

      @@daijoubu4529 If you plan to leave a charger plugged in all the time, tighten screws properly, perform shake test, etc, the residential grade is fine. But periodically check for heat while charging. Use a commercial grade model such as one designed for a RV park if frequent plug & unplug is your routine.

  • @vicb8975
    @vicb8975 Год назад +2

    I liked your review, I agree totally with your findings, I opened my 14-50R outlet in the wall, installed by the builder. I had the cheapo, $10 plug. Wrong plug….the plug was discolored and the wire insulation was discolored and over heated, crinkling after two years of use.
    I bought the Hubble for $100 first, my neighbor bought the Bryant for $50. Exact same plug, except for the brand name. I returned the Hubble and ordered the Bryant. Less demand, less price. All ordered from Amazon..

  • @brois841
    @brois841 4 года назад +20

    I used the Eaton one in my garage for over a year and it was perfect! The fact that you install it upside down is great, because it allows the Mobile Connector to hang off of it without problems. It also means you can flush mount it on the wall without a need to install a huge unsightly box. Mine was permanently connected with the cable hanging on the Tesla Cable Organizer. Wish I could post a picture here, but I think it's short-sighted to rule that one out off the bat... it's a great choice IMO.

    • @97JoMiller
      @97JoMiller 3 года назад +2

      the is the one that I purchased as well

    • @nobodydoingunimportantthings
      @nobodydoingunimportantthings 3 года назад +1

      Bad idea to install upside down for two reasons, 1) it creates tension on the receptacle, 2) it creates tension on the cable.

    • @brois841
      @brois841 3 года назад +5

      @@nobodydoingunimportantthings It's the other way around. When it's installed right side up there's tons of receptacle tension and instead of the cord bending it points upwards creating all sorts of problems.

    • @donnmckinnon
      @donnmckinnon Год назад +1

      Good comment. Another Plus is if the conduit comes from the ceiling

  • @ralphcrawford9741
    @ralphcrawford9741 3 года назад +6

    It seems highly unlikely that any receptacle's contacts are steel, as you have inferred. More likely they are a plated brass alloy. Check them with a magnet.
    The receptacle with half-width contacts as mentioned in a comment, could just as easily have been warmer because of loose wiring.
    When tightening stranded wires into a connection it is IMPORTANT to wiggle and retighten them several times to assure a lasting low resistance connection.

  • @craigl7641
    @craigl7641 4 года назад +3

    I bought the Hubble but haven't installed it yet. It is very well made, the wire clamping looks superior and you need to tighten these connections really well. As current runs through these wires they get hot and expand and contract so a cheaper clamp could loosen and that can drive up heat and that is what leads to electrical fires. So really tighten those clamps.
    One point on the Hubble, the diameter of the plug appears a little larger than the others and that means you may want to get the Hubble face plate that goes with it. It isn't cheap. There may be face plates at your big box store that fit, I didn't try.

  • @motofan16
    @motofan16 4 года назад +7

    Thanks for the video. I installed mine last year with the Leviton since it was the only one in the store. I mostly leave the UMC on so far I don’t have any issue. The biggest problem I had was actually that the heavy duty wires needed to go straight in from the back. I struggled so much to put the whole thing back in the box.

    • @handydadtv
      @handydadtv  4 года назад +1

      Yeah that one needs a deep box for sure.

    • @redzombi2k
      @redzombi2k 4 года назад +3

      @@handydadtv giggity

  • @macsterguy
    @macsterguy 4 года назад +45

    Hubble all the way. I use nothing else in my business and sleep well at night!

  • @oboloori
    @oboloori 4 года назад +16

    No brainer. Go with the Hubble. That’s what I use when building high voltage datacenters.

  • @79bnice
    @79bnice 3 года назад +1

    So glad I saw this video. I just purchased the Leviton nema 14-50 and I will return it asap. Hubbell it is.

    • @handydadtv
      @handydadtv  3 года назад

      Good. Now you’ll have one less thing to worry about!

  • @mrosenblatt
    @mrosenblatt 2 года назад +5

    Another thing to consider: If that Leviton fails, you also need to replace the plug as well - not just the receptacle. The replacement cost adds up fast.

  • @Jaker788
    @Jaker788 4 года назад +8

    I always liked hubbel products. When I'm wiring a charger (for forklifts) up with a plug, I prefer the clamp method of cord strain relief on the hubbel plug. We get good discounts having a partner ID with places like Platt though.
    Others usually use some type of internal clamp that closes as you screw it together.

  • @xoukilong
    @xoukilong 4 года назад +2

    before i got the hpwc, ive been using the Flush Mount Range Outlet for a year and had no problem. the tesla center i picked up my car from uses it too in their showroom

  • @zone07
    @zone07 Год назад +1

    As I'm watching this, I'm seeing a recommended video from the same channel to avoid the Hubbell. I must go watch now....

    • @handydadtv
      @handydadtv  Год назад +2

      Opinions change. 🤷🏻‍♂️

  • @korn010589
    @korn010589 3 года назад +1

    Thank you for making this video. I recently bought a Tesla, and I need to purchase a NEMA 14-50 outlet. Your video made it easy. Thanks!

  • @taylorsutherland6973
    @taylorsutherland6973 2 года назад +1

    This shows the flaw of the rating system of Amazon. People who generally buy this suff on Amazon buy the cheapest option. As a master electrician, we use Hubbell and I absolutely China made stuff at all costs. The Eaton surface mount one you showed is what we commonly install for electric ranges. Ground is always up on any 250 volt recept. I would have no problem using SER cable which is aluminum to something like this in my own home.

  • @FastRedPonyCar
    @FastRedPonyCar 4 года назад +5

    I've got the fully enclosed weather proof Eaton box. It was a bit more @ $45 but it looks nice and since the plug is near the garage door opening, if it's raining hard and the garage door accidentally gets left open, it's one less thing to worry about I guess.

  • @rollswrangler
    @rollswrangler 3 года назад +3

    Leviton 14-50 (Home Depot) with half contact runs hot, charger will drop to 50% occasionally. UPDATE: I replaced all the Levitons with Cooper or Eaton (several locations). Feels cool to the touch even after several hours.

    • @handydadtv
      @handydadtv  3 года назад +2

      Thanks for letting us know

    • @travisr70
      @travisr70 3 года назад +1

      I found this to be true also. Glad I found this video. Using Leviton for over 2 years, randomly gets hot so was looking for a solution. Will try the enerlites as I leave mine plugged in always. Thank you for the great video and hard work

    • @notalenthere
      @notalenthere 3 года назад +2

      I just had my outlet melt the other day. Though I don’t know for sure cause I will be using an industrial outlet (either the Hubble or Cooper) to replace as they use plates to tighten to wire instead of screw as well as better materials for clamps. I like the advice to check heat at outlet.

    • @sdnative2387
      @sdnative2387 Год назад

      ​​@@notalenthere There's the Eaton (Cooper) 5754N industrial grade 14-50.

  • @rawhideslide
    @rawhideslide 4 года назад +4

    I don't get it.
    Are you saying that Leviton is less reliable?
    I have never heard of data collected about number of times you plug into a socket.
    My assumption is that the cheapest of these is going to have a safety factor so high that it would never fail.
    That is the purpose of a UL certification!

    • @handydadtv
      @handydadtv  4 года назад

      I don’t know anything about UL certification and what/how they test. But I assure you, a lot of house fires are caused by electrical devices and panels that are UL certified.

    • @stevejohnson6347
      @stevejohnson6347 4 года назад +2

      I agree entirely (unless the unit is a Leviton knock-off...if there is such a thing...lol).

    • @brois841
      @brois841 4 года назад +1

      The Leviton will be just as reliable if you don't plug/unplug the connector. ONLY IF it's a permanent install. As soon as you start unplugging it, it WILL be less reliable 100%. These outlets are meant to power your dryer, which is plugged/unplugged a few times in the receptacles lifetime. If you unplug your Tesla connector every night.... do NOT skimp, get an industrial connector. The last thing you want is a house fire.

  • @michaeld.8311
    @michaeld.8311 Год назад

    Thanks for doing the review, but knocking out the Eaton because you "don't think it would LOOK right"? If you bring wire from your ceiling it is NOT hanging upside down. It has the ground up when coming form the ceiling and looks great.

    • @handydadtv
      @handydadtv  Год назад

      Fair point but I still don’t like that one for EV charging. I’ve seen pictures of it melted.

  • @WanderingGipsy
    @WanderingGipsy 6 месяцев назад

    There is an improved Leviton 14-50 improved outlet 279-S000 which is roughly $12 and that may contend well with all other choices besides Hubbell

  • @kranwa15
    @kranwa15 Год назад

    While researching for a heavy industrial outlet, i found a little less pricey outlet by Bryant Electric 9450FR 50 Amp 125/250V NEMA 14-50R sold for about $48, apparently Hubbell and Bryant are from the same company.

    • @handydadtv
      @handydadtv  Год назад

      Hubbell NEMA 14-50 is TOO EXPENSIVE! Do this instead.
      ruclips.net/video/R2cRNzSbw48/видео.html

  • @Paxmax
    @Paxmax 4 года назад +5

    E-vehicle charging is a high demand job, it will use the devices full capacity for hours on end... it makes no sense to skimp on this one-time cost.

  • @DanBurgaud
    @DanBurgaud 8 месяцев назад

    5:50 The Ground prong should be in the TOP position, regardless if it is for EV, Stove, Drier or a Power tool.
    I do not know why EATON put it at the bottom.

  • @joemaldonado3
    @joemaldonado3 3 года назад +6

    thank you. in Spanish we have a saying "lo barato sale caro", the cheap ends up costly.

  • @chargermopar
    @chargermopar Год назад

    I have Eagle and Leviton Nema 10-50 outlets that are over 30 years old. None have failed and all made in the USA. If you ever have to use a screw terminal you need to crimp a sleeve over your wire ends and torque your screws correctly.

  • @R900DZ
    @R900DZ 4 года назад +7

    The UMC draws 32 amps, not 50 as mentioned in the video. Thank you for showing us all of the options

    • @handydadtv
      @handydadtv  4 года назад +4

      I was speaking based on the breaker capacity. Didn’t get that specific.

  • @joecox9958
    @joecox9958 2 года назад

    thanks! I'will change to eaton due to my wires comes from ceiling. if you use others except for #1 of thin one, 1/4 wire would be difficult to get to the other end.

    • @handydadtv
      @handydadtv  2 года назад

      It’s possible to bring them up and over the top. Watch this week’s video to see how I did it with a 6-50 outlet ruclips.net/video/XNOnVxI0tvk/видео.html.

  • @MikeSiemens88
    @MikeSiemens88 Год назад

    Not sure if the Tesla Wall Connector was available 2 years ago, but nowadays If you're going to spend almost $160 for a Hubble you might just as well splurge for the Tesla proprietary connector wired on a 60 amp circuit. Just because the Nema 14-50 connector is protected by a 50 amp circuit breaker doesn't mean the car charger is going to draw full current. Typically any household circuit is designed to work at 80% of rated current continuously. A properly wired 15 amp circuit should be designed so that the load never needs to deal with continuous 15 amp draw for safety reasons. I guess what I'm saying is that provided all the Nema connectors you reviewed meet National Electric Code specifications they should be more than adequate to charge your Tesla safely. I'd be inclined to buy the Leviton.

    • @handydadtv
      @handydadtv  Год назад

      I definitely recommend a hard wired charger over an outlet. If you must have an outlet, I only recommend Hubbell or Bryant.

  • @andrerodriguez7603
    @andrerodriguez7603 3 года назад +1

    I used the Leviton 3 years non with no issue. I would think if it fails the breaker will trip.

  • @envisionelectronics
    @envisionelectronics 2 года назад

    I thought this was the case too, as I never unplug my Mobile Connector. But after about a year I was getting overheat warnings on the Leviton - same as the one in your video. I dutifully retorqued the terminals and after another six months, I got the warnings again. This time the terminals were still tight but the internal contacts were weakened and vibrating with the current. Using a contact stethoscope I could hear the 60Hz hum in the receptacle that would change as I moved the plug back and forth a little. Not unplugging it, just rocking without unplugging. So the internal contacts were weakened after almost two years of daily use (I drive a lot).

    • @johnpoldo8817
      @johnpoldo8817 2 года назад

      If you feel a marked increase in temperature, immediately replace receptacle to avoid a melt-down. If the contacts are visible, you may see carbon deposits. If on a very tight budget and handy, you may be able to refurbish receptacle, but most people don't take the risk.

    • @handydadtv
      @handydadtv  2 года назад

      Luckily Tesla has a temperature sensor in the plug. I wish they were all made that way.

  • @athuddriver
    @athuddriver 3 года назад +3

    I'm in the process of a home being built and adding an EV outlet. The reviews of the outlets was very helpful. Perhaps this is a side bar but why does Tesla say you need a 50A breaker? To the best of my knowledge, none of the Teslas charge at a rate greater than 32A. The 125% breaker sizing means you only need a 40A breaker. Any thoughts on that?

    • @fredmauck6934
      @fredmauck6934 3 года назад +1

      There are no receptacles currently available for 40A. So, you upsize to the next ampereage size. You can use a 40A breaker and use #8 wire. People do that with Electric Ranges all the time.

    • @rickhall7955
      @rickhall7955 2 года назад +1

      While it is true the Mobile Connector will only draw 32, the NEMA 14-50 outlet is rated for a constant draw of 40 and requires a 50 amp circuit breaker to meet code. Even the Tesla Mobile Connector Gen 1 draws 40 amp, and you don't know what the next person who buys your home might plug in. Why cheap out on the circuit breaker?

    • @athuddriver
      @athuddriver 2 года назад

      @@rickhall7955 The house is done and I opted for a 50 amp circuit/breaker and the more expensive Hubbell outlet & cover plate. What started my question was that the electrician (for some reason) only wanted to install a 40amp set up. I'm with you on the basic question about what could come next. On top of that, using a properly built 50amp set up is just smart for safety. THANKS!

  • @jamesdaniel947
    @jamesdaniel947 Год назад

    You kind of glossed over the Hawking in your final analysis, preferring to go for the Leviton compario. I have a Vevor model RV-50A outdoor Power Outlet Box, which has the Xiognda receptacle in it, made in China. The heavy duty steel box is powder coated and should last a long time.
    Being made in China used to mean cheap knock-off, but that has changed radically over the years. Vevor is also a Chinese company, and its aphorism is “Tough tools, half price”. I really like the Hubble clamps, but are they absolutely necessary? The wear and tear is inside on the brass clamps where the forks go in, and I like your suggestion of just leaving it plugged in. It seems to be working fine for now, and some day will replace it. I feel the plug when it is charging and it is lukewarm but not hot. Is it worth changing? How many amps is the Mach e drawing when it is on its built in charger? It ain’t a Supercharger…

    • @handydadtv
      @handydadtv  Год назад

      Thanks for the feedback. There’s no reason to charge your car fast in 2 hours if it sits in your garage all night. My EVSE can go up to 32 amps but I personally charge at 15 amps on the daily.

  • @at906
    @at906 3 года назад +4

    If you found a 500$ outlet? Would you have justified that purchase as well? Peace of mind?

    • @kungfoochicken08
      @kungfoochicken08 Месяц назад

      $500 is a bit too much. At that price, it’s cheaper to just buy a $100 receptacle and a $200 mobile charger that you permanently leave plugged into it.

  • @SuperFredAZ
    @SuperFredAZ 3 года назад +1

    Just because the contacts look like brass, I wouldn't assume that they are. The Chinese are prone to using brass plated material. One simple way is to bring a magnet to test.

  • @Joel-re1jz
    @Joel-re1jz 5 месяцев назад

    I have a NEMA 10-30 outlet in my garage. I saw a variable EVSE that I can move to 24Amps and get an adapter from 14-50 to 10-30. My only question is there is a green wire coming out of the wall as well (i'm guessing that is ground) Do I need to do something with that? I'm charging a Chevy Bolt EUV.

    • @handydadtv
      @handydadtv  5 месяцев назад +1

      I hesitate to comment because I can’t be sure why a green wire is coming out of the wall instead of being connected to the outlet. I also don’t like using adapters. Unless you need to keep the 10-30 for something else, I would just replace it with a 14-50 receptacle. You’d still need to keep the 30 amp circuit breaker and charge at max 24 amps, but it would be safer than a cheap Chinese adapter from Amazon.

    • @Joel-re1jz
      @Joel-re1jz 5 месяцев назад

      @@handydadtv I think that is the proper way, future proof the outlet by updating to a 14-50 then labeling as 30 Amp. Hopefully there is a ground in the outlet.

    • @handydadtv
      @handydadtv  5 месяцев назад

      @Joel-re1jz The green wire is likely a ground. But you need to test it.

  • @troyfall6573
    @troyfall6573 Год назад

    The Hubbell 14-50 now cost $110 on Amazon. Hubbell makes the Bryant brand that is sold at Grainger. It is the exact same plug but sold under different brands. Grainger sells the Bryant one for $45.

    • @handydadtv
      @handydadtv  Год назад +1

      I did a follow up video on that topic:
      ruclips.net/video/R2cRNzSbw48/видео.html

    • @troyfall6573
      @troyfall6573 Год назад

      @@handydadtv Good, it is a shame that sellers are getting greedy and gouging consumers. It is important to get a commercial grade outlet but $110 is out of hand. Good info to share alternative options.

    • @handydadtv
      @handydadtv  Год назад

      Capitalism at work.

  • @chriswestring1974
    @chriswestring1974 4 года назад

    I just ordered the Hubbell. I agree that you don't want to go cheap. I want to run the wires through a conduit with wires already going through it. It's only a 10 foot run from the breaker box to the outlet. To save space in the conduit, can I use 6 Awg wire for the red and black but 8 Awg for the neutral?

    • @handydadtv
      @handydadtv  4 года назад

      No all three should match. But you can use a 6-50 outlet and only need 2 conductors.

  • @colinpovey2904
    @colinpovey2904 2 года назад

    2 years after you published this, March 30, 2022, the Hubbel is now $159.99!
    BTW, good practice to check heavy duty outlets like this after about 6 months for warmth and loose wires. As in power down, take apart, and tighten screws.

    • @handydadtv
      @handydadtv  2 года назад

      The 14-50 has become the defacto standard for EV chargers and that demand has driven prices up. I’m working on a video to talk about cheaper alternatives.

    • @colinpovey2904
      @colinpovey2904 2 года назад

      @@handydadtv Most smaller EV's (Leafs, Mini, that weird BMW, etc.) specify the NEMA 6-20.The 6-20 is also useful in home shops, for large saws, vacuums, pressure washers, etc. In this way, one outlet can do double duty.
      Here is something you might want to point out: Using a NEMA 6-20, which is 240 volts, 20 amps, is more efficient than 120 volt, 20 amp circuit. 240 Volt AC power converts to DC more efficiently.
      Tesla clearly shows this, if you compare a NEMA 5-20 (120 volt, 20 amp, now standard in some places in new homes) outlet with a 6-20 outlet (240 volts, 20 amps). The 5-20 provides 4 miles per hour of charging to a Model Y, while the 6-20 provides 14 miles per hour of charging, more than enough for many Tesla users (8 hour of charging provides 112 miles of charging, enough for most users, and less expensive to install. You have doubled the power (120 to 240 volts at the same current), yet the charging potential has almost tripled! The reason is multiphase power converts more efficiently to DC than does single phase.
      In other words, installing at least a 6-20 can save you money over using a 120 volt outlet over a short period of time. The 6-20 is also easy to install, using standard 12 or 10 gauge Romex.

    • @handydadtv
      @handydadtv  2 года назад

      That’s a really good point! I just think Tesla owners go for top performance in everything, even charging. It’s in their DNA to spend money to get the best. Know what I mean?
      I also think the majority of owners ARE NOT the kind of people to do their own electrical work. So if they’re hiring an electrician to run a new circuit, the labor is the most expensive part of the bill anyway. The cost difference to do 20-amp to 50-amp may be negligible.

  • @gordon4385
    @gordon4385 3 года назад

    We had a 220v line installed in our garage this summer and I asked if they used Hubble. They used a Leviton, but if I start getting a lot of heat when I charge the car, I'll swap it out for a Hubble myself.

    • @handydadtv
      @handydadtv  3 года назад

      Let me know if you feel a difference.

  • @SpencerSkelly
    @SpencerSkelly Год назад

    Thanks for bringing some attention to the outlet as a part of the charging system. I feel it's often overlooked.

    • @handydadtv
      @handydadtv  Год назад +1

      Three years later, my views have changed. Watch ruclips.net/video/1BnK4a4aVpU/видео.html

  • @fernandopenah
    @fernandopenah 4 года назад +3

    Nice review. Consider including whether outlet is UL listed or not.

  • @steinwaymodelb
    @steinwaymodelb 4 года назад +1

    Check local electrical suppliers for the Hubbell... I've bought half a dozen of these for RV and generator hookups and paid less than $10 for that exact receptacle.

    • @handydadtv
      @handydadtv  4 года назад

      Wow I’m shocked. (Pun intended)

  • @CorbinWilliams
    @CorbinWilliams Год назад

    Would love to see an update of this video, so new EV owners searching the web today will be likely to see this important information. Very well presented and gives a lot of important context about each nema outlet.

    • @CorbinWilliams
      @CorbinWilliams Год назад

      I bought the Hubble plugs 2 years ago after watching your video, it’s worked great ever since.

    • @handydadtv
      @handydadtv  Год назад

      Thanks for the comment. I will put it on my list.

  • @TheHypnotstCollector
    @TheHypnotstCollector Год назад

    we have a Tesla glass solar roof and two power walls. And just the other day bought a Tesla model 3 dual motor. So now we are installing the charger system. The electrical wiring is now all Eaton. So I am tempted to buy the Eaton receptical. The cord will stay home, plugged in most of the time. And I don't believe in upside down! But we will probably buy the Hubbell. 2023 Tesla's don't come with the cord, you gotta buy it now. We bought a 32A, approx $270.

    • @handydadtv
      @handydadtv  Год назад

      My recommendation is to buy the hardwired wall connector.
      But if you really want an outlet, the brand doesn’t need to match the wiring. Just make sure you go with an industrial outlet.

  • @perryrodebaugh5513
    @perryrodebaugh5513 2 года назад

    The Hubbell has stronger contacts. I have seen cases where the cheap ones have melted. FYI the hubbell has a slightly larger diameter and needs a special cover plate.

    • @handydadtv
      @handydadtv  2 года назад

      Yeah I learned that the hard way.

  • @tuantang4770
    @tuantang4770 2 года назад

    you are right if I get a tesla I will get Hubell nema too thanks for the video you are the best love any of your video since day one

  • @BeemerToTesla
    @BeemerToTesla Год назад

    Is the Leviton ok to use? I’m reading that it’s been melting for some people after a couple months use? Is it doing that because the wires aren’t tightened or is it because of the quality? Or could it be from using a 60 amp breaker instead of a 40 amp?

    • @handydadtv
      @handydadtv  Год назад

      Buy an industrial outlet. Or just hard wire it.

  • @jmlastname4412
    @jmlastname4412 2 года назад

    The expensive Hubbell has fewer reviews because most people buy the cheaper versions. As an installer I refuse to use a cheapo device for EV charging. The cheap device is designed for short duration use. Not for the constant load of charging.

  • @mattd00d82
    @mattd00d82 4 года назад +1

    Any suggestion for outdoor?

  • @yanbingwang6058
    @yanbingwang6058 2 года назад

    Hi, thanks for all the information. I purchased a industrial grade nema 14-50 outlet. It require 2.465" diameter cover. However, I only can find flush mount cover with this size but can't find exposed work cover for this size. Could you recommend one for exposed work cover? Thanks!

  • @leefamilytx
    @leefamilytx 2 года назад

    Exactly what I was looking for - thank you for this video. Problem is the Hubbell recepticle (HBL9450A) now costs $163. WoW! I'm searching for a lower price on this product. Appreciate any leads on this research...

    • @handydadtv
      @handydadtv  2 года назад

      ruclips.net/video/XNOnVxI0tvk/видео.html

  • @JustAnAcre
    @JustAnAcre 6 месяцев назад

    Would be good to have Leviton tech support weigh in on its receptacle...seems to me, if one installs with ground orientation up, adapter plugged in and fixed in place with clamps, there should be no issues.
    I split charge off one receptacle to 2 EVs this way and have had no issues with the Leviton. Its UL listed to 50amps. I think something is very wrong when it doesnt hold up and Leviton still stocks them.
    Hubbel must have had a nice dinner with Elon.

    • @handydadtv
      @handydadtv  6 месяцев назад

      They don’t specify Hubbell anymore. They just require an industrial outlet.

  • @dw4070
    @dw4070 4 года назад +1

    This is great info, thank you! I will let the electrician provide the 6/3 wiring but would like to order the Hubbell 14-50 receptacle and 50A breaker in advance. Any advice on specs for the breaker? I was going to go with Square D but single pole? Double pole? Etc?

    • @handydadtv
      @handydadtv  4 года назад +2

      Needs to be double-pole and it needs to match the brand and type for your electric panel.

    • @dw4070
      @dw4070 4 года назад

      Thank you!

  • @fredsalter1915
    @fredsalter1915 3 года назад +1

    Do we need to bother using the neutral wire? I don't think it gets used anyway. Just curious. And thanks for the Hubbell tip!

    • @handydadtv
      @handydadtv  3 года назад +4

      The Tesla UMC doesn't use the neutral, so you can install a NEMA 6-50 instead of a 14-50 and save a little money on the copper. HOWEVER, I would still recommend the 14-50 for greater compatibility with RVs and other EV chargers in the future.

  • @DanBurgaud
    @DanBurgaud 8 месяцев назад +1

    7:04 Forget the $$$ and reviews! Just look at that hefty clamp! IT is a BUY!

  • @MikeMcCutchen-hw9vi
    @MikeMcCutchen-hw9vi Год назад

    What about the Intertek 50 amp receptacle? It came in the outdoor RV outlet box I purchased

    • @handydadtv
      @handydadtv  Год назад

      I have no experience with that brand.

  • @DanBurgaud
    @DanBurgaud 8 месяцев назад

    "BRASS" vs Copper vs Aluminum
    Brass is harder and springy - will return back to its original position. However it has poor ~30% conductivity. Expect it to heat up.
    Copper is softer and will easily deform when used as a socket. Yeah I had one and it suck! But it has 100% conductivity.
    Aluminum is in the middle, with 60% conductivity. It unfortunately corrodes and become a hazard.
    There is one (extension) socket (forgot the brand) with copper plate contacts BUT backed by springs to make perfect contacts all the time! It makes for a great extension, my power tool wont go unplug even when yanked!

    • @handydadtv
      @handydadtv  8 месяцев назад

      Thanks for the info.

  • @007BondMI6
    @007BondMI6 3 года назад +1

    I am not debating which one is best, but it was totally unfair to rule out the Eaton (or any surface mount brand of similar design). First if you were going to rule it out for mounting it upside down then all the outlets should have been ruled out if there was any logic or valid reason to this. Second no where in the NEC does it specify mounting orientation direction for this outlet. Third the instructions clearly state Universal Surface Mount. Retired now but there is nothing wrong with mounting the Eaton or any similar style surface mount brand in any direction. I have mounted many behind stoves in whatever direction yields the best cord management and safety. Bottom line if you are removing the plug many times there will be wear and tear. Further the more current you draw the more heat so this is also wear and tear. If you notice the amount of force to install the plug when new and then compare it after years you will find it's less. Most stoves are used 1 or 2 burners at a time and once in a while the oven and never for hours and hours except once a year on Thanksgiving. So these instals don't see much high current draws for many of hours. But with an EVSE you could be drawing 40 amp for 8 hours if you were at 5% SOC and could be many days a week. So as you can see the wear and tear on an outlet used for EVSE is under much more heavy duty use. I recommend to replace the outlets every several years to avoid any issue it's cheap insurance as they all wear regardless of brand. Thanks for the video.

    • @handydadtv
      @handydadtv  3 года назад

      Thanks for the tips! 👍🏻

  • @inediblenut
    @inediblenut 3 года назад

    I totally agree with your recommendation. If you are doing the work yourself, you are already saving hundreds of dollars. Better to go with the best device and do the job once. Also, the clamping method of wire connection just sounds so much more secure and safe to me. I don't think I saw any mention of the circuit breaker needing to be GFI, but if its in the garage or outdoors, you will need to use one of those to be code compliant (as well as safe.) That is going to cost you over $100, too. Add $65 for 100 feet of 6/3 copper wire and $20 for a box, staples, cover plate, and you are still under $300 for the job, saving at least $300 on having it done by an electrician.

    • @handydadtv
      @handydadtv  3 года назад

      I still haven’t installed it (haven’t been commuting!) but I don’t remember the Tesla installation guide saying it needed a GFCI circuit breaker.

    • @inediblenut
      @inediblenut 3 года назад

      @@handydadtv I said that based on the NEC requirement that most municipalities use for code compliance. Here is the reference "The NEC mandates GFCI protection in many areas of the home: bathrooms, garages, outdoor receptacles, crawl spaces, basements, kitchens and anything within six feet of a sink or water source." Tesla probably should update their instructions, since 90% of installations would probably be either outside or in a garage.

    • @handydadtv
      @handydadtv  3 года назад +1

      There is some debate on whether a GFCI is needed for the UMC outlet, and some say it causes issues. forums.tesla.com/discussion/177035/anyway-of-making-the-ride-smoother

    • @inediblenut
      @inediblenut 3 года назад

      @@handydadtv Thanks for the heads up, HandyDad! I want to look into this before I install a circuit.

    • @ngouviet420
      @ngouviet420 2 года назад +1

      100 ft for 65? your out of your mind... its like 6 bucks a ft..

  • @kalmanmahlich9959
    @kalmanmahlich9959 4 года назад +2

    This is actually so useful thank you!

    • @handydadtv
      @handydadtv  4 года назад

      Thanks glad it was helpful

  • @Gallardo6669
    @Gallardo6669 3 года назад

    Great video, I just watched it again...!
    Is the Hubbell having a full lengthy contact surface to allow max current delivery??
    Since a few months a have some connection issues with my Tesla...
    Are there a actually double receptical out there??? I have a 60amp capable cable and need to feed 2 30 amp devices.
    Thank you again for your video. Your voice is also very pleasant!

    • @handydadtv
      @handydadtv  3 года назад +1

      Thanks 😊 The Hubble grabs the full width on both sides of the prongs.

  • @afmx1
    @afmx1 2 года назад

    Thanks for the reviews. I ended up going with hardwired because of your review.

    • @handydadtv
      @handydadtv  2 года назад

      Good choice so you also avoid needing a GFCI breaker.

  • @jankeshchakravarthy9389
    @jankeshchakravarthy9389 4 года назад

    Hi, What is difference between 2pole and 3 pole? Does it really matter? Please share your thoughts.

    • @specialopsdave
      @specialopsdave 3 года назад

      2 pole 240v will only work as 240v between the 2 hot poles, whereas you can get an adapter to convert 3 pole 240v to 2 separare 120v circuits by getting the 120v between either of the two hot poles and the neutral pole. 3 pole is required for some appliances that use both voltages, and RVs. 2 pole will work with welders and other equipment that needs only 240v.

  • @RandomYoutuber1023
    @RandomYoutuber1023 2 года назад

    The Bryant 9450FR is 2nd place to the Hubbell and also made in the USA.

  • @xmedia-e
    @xmedia-e 3 года назад +1

    Great review! Hubble it is. Hubble's website says it can stand at 2,000V minimum.

  • @court2379
    @court2379 2 года назад

    Are you sure those contacts are steel? I really doubt it. Put a magnet on them. I think they are tin plated brass, which is actually better than the others. They don't corrode as much.
    Also I was trying to watch to see if the temperature ratings were different.
    The Eaton is designed to make an extension cord. That is why the prongs are rotated 180.

    • @handydadtv
      @handydadtv  2 года назад

      Now I have my doubts

    • @court2379
      @court2379 2 года назад

      @@handydadtv It is too bad you cannot overlay corrections/clarifications to videos anymore...

  • @DougSims
    @DougSims 2 года назад

    One reason there aren’t a lot of reviews for the Hubble is that most people are buying them locally or through an electrician. So they are not buying the higher quality outlets from Amazon.

  • @adrianflury2657
    @adrianflury2657 2 года назад

    I have AL prewire in the wall. I would like to use the Hubbell receptacle. In the video at 7.53, on your handwritten summary you say Hubbell "AL-CU wire", but on the left side screenshot "NEMA 14-50 Details" it says "Copper Wire only". I'm now confused, can I use the HBL9450A with AL wiring?

    • @handydadtv
      @handydadtv  2 года назад

      No. Hubbell is copper only. That was an error in the video.

  • @dkohler5226
    @dkohler5226 3 года назад +1

    In my experience most if not all electrical products made off shore are copper/brass clad steel metal connections, this is why the weight of the last plug is double the weight. HBL9450A PS. I don't go by reviews because I believe the reviews can be flooded/faked both ways, good for one item and bad for another.

  • @RNbiker57
    @RNbiker57 4 года назад +1

    Thanks so much! I'm about to install one of these for my Chevy Bolt.

  • @useemehere2
    @useemehere2 2 года назад

    Great review for all EV charger outlet. Very useful information.

  • @3qgc
    @3qgc 4 года назад +2

    Great video HD! Just added the Hubbell to my shopping cart on Amazon. Of course, used your affiliate link. Do you think it's ok to run the 6-3 wire for a 100' run? Did you ever film the installation of your 14-50?

    • @handydadtv
      @handydadtv  4 года назад

      100-foot run should be fine. I haven’t installed mine yet! Since making this video, I moved into a new house so I brought the Hubbell with me to install here when I eventually get commuting back to work! Stay tuned...

    • @CristobalHernandez
      @CristobalHernandez 4 года назад

      @@handydadtv Staying Tuned :D Looking forward for that video too.

  • @loulinjai
    @loulinjai 2 года назад

    Thanks for all the educational videos you produce, they are easy to follow. With the Hubbell 14-50 being out of stock for many vendors, do you have any opinions on the Hubbell RR450F for EV charging? Thanks

    • @handydadtv
      @handydadtv  2 года назад +1

      The RR450F is residential grade, not industrial grade. As an alternative industrial grade, look for the Bryant 9450FR at Grainger. Much better price too.

    • @loulinjai
      @loulinjai 2 года назад

      @@handydadtv sincerely, thanks for all the good insight in your videos and comments

    • @handydadtv
      @handydadtv  2 года назад

      Watch my latest video for more on this subject. ruclips.net/video/R2cRNzSbw48/видео.html

  • @thedrewwitt
    @thedrewwitt 2 года назад

    Hey! I have a 10-30 already installed in my garage workshop (with two 30amp breakers) - is it worth changing it out for a 14-50?

    • @handydadtv
      @handydadtv  2 года назад

      No. If you have a Tesla, just get the 10-30 plug for the UMC.

  • @dajo4349
    @dajo4349 4 года назад

    Good info. Does the Tesla use 120 volts when charging from the 14-50 outlet? I have a 6-50 outlet and am thinking of changing to 14-50 to match a relative's 14-50 for their Tesla when we go to visit. On the other hand, I could just get 2 adapters, one for each outlet and call it good...

    • @handydadtv
      @handydadtv  4 года назад +1

      6-50 only has two wires (plus ground). 14-50 has three wires so you likely can’t swap it. But I wouldn’t waste your time anyway. Just get two adapter.
      BTW, both 6-50 and 14-50 are 220V outlets so you’ll get an equally fast charge from both.

    • @dajo4349
      @dajo4349 4 года назад

      Thanks!

  • @jasons7044
    @jasons7044 2 года назад

    If you use one of these that have screws clamp to the wires use ferruls on the wire ends

  • @philjans1
    @philjans1 10 месяцев назад +1

    LET me tell you: GO with the BEST quality!
    I use the Leviton box and 3 times it melted! Which means came near to FIRE 🔥
    AND I’m not even using an”portable” I have a fix EvDuty charger so Imagine if you unplug every day.
    Now I bought a Bryant which is QUALITY and more expensive.
    If it fails: I’ll open my charger and hardwired it

    • @handydadtv
      @handydadtv  10 месяцев назад

      I always recommend hard wiring.

  • @daijoubu4529
    @daijoubu4529 2 года назад

    Also, are the contacts really steel just because they are silver colored? Could be just nickel plating, tested with a magnet?

    • @handydadtv
      @handydadtv  2 года назад

      I didn’t test with a magnet.

  • @wvc72
    @wvc72 3 года назад

    Great review but I could not find the link for the Hubble nema 14 50 you found and you recommend which is I seem to be by that I agree with you could you send me a link please it's really urgent that I get it as soon as possible as it possibly the price went down on Amazon so you don't see it. $68 as you said

    • @handydadtv
      @handydadtv  3 года назад

      The link still works, but the price has increased from when I published that video.

  • @emekliyim
    @emekliyim 3 года назад

    Thank you for your explanations. Can I use this plug in Turkey 220 V electric.

    • @handydadtv
      @handydadtv  3 года назад +1

      I doubt it. The “N” in NEMA stands for National. Meaning United States.

    • @emekliyim
      @emekliyim 3 года назад

      @@handydadtv thank you

  • @mikenelson799
    @mikenelson799 28 дней назад

    A Tesla mobile charger doesn't draw 50 amps. Even without looking at the specs on the mobile connector unit, it can only load the circuit to 80%, so it's maximum allowable draw would be 40 amps.

  • @steveb796
    @steveb796 4 года назад

    I bought the Hubble and had it installed. Tesla isn’t showing an adapter without buying the $220 multi adapter pack. Thought I was getting the correct 4 prong adapter when I checked 6/50 when ordering but only got 3 prong. (2 plus ground). The adapter I got say 6/50 in it but also 30 amp / 250 volt. Am I missing something?

    • @handydadtv
      @handydadtv  4 года назад

      The 14/50 and 6/50 outlets are both 50-amp max. The 6/50 only requires two conductors; the 14/50 adds a neutral. Tesla doesn’t use the neutral, but other devices (welders, RVs, etc.) might need it.
      The adapters are very popular and get sold out often. Have patience and check back often.

    • @steveb796
      @steveb796 4 года назад

      @@handydadtv thanks for the quick reply. The 6 /50 has a different prong layout than this Hubble plug. Can you confirm that the 14/50 fits? Sorry to sound like a dunce- this isn’t up
      My alley.

    • @handydadtv
      @handydadtv  4 года назад +1

      No, 6/50 is a different plug and outlet. If you’ve already got the 14/50 installed, just wait for the adapter to come back in stock.

  • @xoukilong
    @xoukilong 4 года назад +2

    lol i bought the same one tesla got in their showroom. that white plastic one. if this video was out last year. i'd probably either get the black center one or the hubble

  • @johnsiotis8870
    @johnsiotis8870 3 года назад

    Hey. I currently have a 30 stove plug outlet that I am no longer using. Was wonder if I can repurpose that circuit for an outside tesla charger? Is there a 30 amp outlet that will work with the tesla umc?

    • @handydadtv
      @handydadtv  3 года назад +1

      Yes, you can buy the 10-30 or 14-30 adapter for the UMC, then change the outlet to match. 14-30 has a neutral; 10-30 does not.

  • @vijaybabaria3253
    @vijaybabaria3253 2 года назад

    would someone pls recommend for "outdoor" outlet with the box for waterproofing? thanks

    • @handydadtv
      @handydadtv  2 года назад +1

      The outlets are the same; you just need an outdoor box that’ll fit it.

  • @dylancolebrooke693
    @dylancolebrooke693 2 года назад

    Supply house sells other brands "like legrand" and the eaton version of the 14-50 you mount in a box

  • @alvinhoang1800
    @alvinhoang1800 2 года назад

    Awesome Video, this is what I need. the Hubble cost is so high now. Ahhhhh $162 on Amazon now.

    • @handydadtv
      @handydadtv  2 года назад

      There is an alternative ruclips.net/video/XNOnVxI0tvk/видео.html

  • @31borya
    @31borya 4 года назад +4

    Why is the $70 better than the $15? Both look brass. Is there difference in plating that would make one endure more plug/unplug cycles than the other, or what?

    • @brois841
      @brois841 4 года назад +5

      Industrial grade NEMA 14-50 connectors are meant for high duty cycles (meaning: you can plug/unplug it many times). Standard connectors are only rated for a few hundred cycles at most, since they're meant to plug in a dryer once and forgetting about it. If you use them often, you'll wear and stretch the contacts which will ultimately means your connector won't stay put, but may also cause arcing.
      Bottom line: if you plug/unplug your connector a lot, get the expensive outlet. If you leave your connector plugged in and maybe unplug it a few times per year, get the cheaper connector.

  • @emadtubeyou
    @emadtubeyou 4 года назад

    I was planning to install my plug upside down so the ground prong is down until I watched this video. It says Tesla asks for the ground prong to be up. Is this a must and if yes why?

    • @handydadtv
      @handydadtv  4 года назад +1

      The adapter plug has the ground pin in the opposite direction of the cord. If you hang the Tesla charger down below the outlet, then ground pin goes up. If you attach the charger to the wall above the outlet, ground pin goes down.

  • @FillingTheGap1
    @FillingTheGap1 4 года назад +1

    +1 Hubble. Will install it soon. The leviton is junk, mine overheats constantly and that's only 32amp

    • @handydadtv
      @handydadtv  4 года назад

      Thanks

    • @FillingTheGap1
      @FillingTheGap1 4 года назад

      @@handydadtv Your welcome. It's a very useful video. The others look better then I thought actually.

    • @stevejohnson6347
      @stevejohnson6347 4 года назад

      Interesting. What wire are you running and what length?

    • @FillingTheGap1
      @FillingTheGap1 4 года назад +2

      @@stevejohnson6347 its the tesla recommend AWG size. Copper. Right next to electrical box. The Hubble stopped the overheating. Works much better.

    • @travisr70
      @travisr70 3 года назад +2

      My Leviton overheat also with 6 gauge copper will be changing it. Thanks for information

  • @jarikinnunen1718
    @jarikinnunen1718 2 года назад

    If is smallest risk of fire by wall outlet, why put it in wall in first place? Have you lost some screws?

    • @handydadtv
      @handydadtv  2 года назад

      These days, I’m promoting the use of hard-wired chargers instead of outlets.

  • @jjmst55
    @jjmst55 4 года назад

    Great video. Thank you. Any recommendations on a specific 50amp breaker?

    • @handydadtv
      @handydadtv  4 года назад +2

      It needs to match your panel. Don’t mix brands.

    • @erbewayne6868
      @erbewayne6868 2 года назад

      Also look at the 2020 nec regarding gfci protection.

    • @handydadtv
      @handydadtv  2 года назад

      GFCI breaker is covered here: ruclips.net/video/BixGQisysDc/видео.html

  • @jasonhadid7477
    @jasonhadid7477 2 года назад

    You don't need a 50 amp breaker for the UMC, nor do you need 6/3 wire.
    The maximum draw of the UMC is 32 amps on a 40 amp circuit. Therefore useless to install anything over 40 amp breaker with 8/3 wire (even 8/2 wire will work for Tesla UMC but not with some other chargers). Code does not require 50 amp breaker for NEMA 14-50 outlet, minimum requirement is 40 amp breaker with 8 AWG wire. I would only use 6 AWG wire if I had a really long wire run (over 50 feet), to reduce voltage drop over long distances.

  • @HelmuthBaum
    @HelmuthBaum 3 года назад

    Awesome video, thanks for the review!!

  • @montiraruba2831
    @montiraruba2831 4 года назад

    Great video. Me, I do not settle for the cheap ones. There is a reason Tesla recommended the Hubbell. I am sure that Tesla has done their research with NEMA plugs. If I am riding on my expensive investments, why would I settle for a cheap NEMA plug? Remember the old saying, "You get what you pay for." It is like, if I own an expensive Porsche race car, would I buy some cheap Chinese made tires for it?

  • @sdnative2387
    @sdnative2387 Год назад

    There is an Eaton 15-40 industrial grade option (Model 5754N). It's almost as expensive as a Hubbell.

    • @handydadtv
      @handydadtv  Год назад +1

      Don’t use an outlet. Hard wire.

    • @sdnative2387
      @sdnative2387 Год назад

      @@handydadtv Will do, thank you! I've notified the electrician of the change of we wishes.

  • @PhilT993
    @PhilT993 4 года назад

    Thank you for this video. You had talked me into the Hubbell until I saw the price in Canada of $176.61CDN.

    • @handydadtv
      @handydadtv  4 года назад

      Ouch 😳

    • @kriley9386
      @kriley9386 3 года назад

      Philip T, that can’t be right. Must be a decimal in the wrong place. $17.66 CDN?