How it works.... How fresh water is generated onboard ships..
HTML-код
- Опубликовано: 7 фев 2025
- How fresh water generator works # How fresh water is produced using sea water # components in fresh water generator # function of ejector # Function of salinity indicator # Function of vacuum adjust valve # Function of vacuum breaker # function of condenser # Function of Evaporator # Function of preheater # Function of relief valve
Follow us on :
Facebook - www.facebook.c...
Instagram -
/ marine_engineering_basics
Your vedios are very useful sir
Thanks for your good compliment sir.. Requesting you to share our channel with ur friends and subscribe
Super sir ❤❤❤pakka 😊
Thanx s lot for your good compliment
great vedio
Thank you sir
Very informative sir
Thank you sir
Super je
thnks ji...
Could you make vedios on generator tappet adjustment and generator firing order setting of after removal cylinder head overhaul of all unit ..
Sure vl do sir.. Pls giv some time
👍👍👍👍👍
Nandry manna
excellent
Thanks sir...keep supporting
Condenser unit
Phase change vapor to liquid
Ejector venturi principle convergent divergent nozzle here Bernoulli principle p. Increase v. Decrease p.decrease v.increase there through for suck the brine on low pressure
Brine ejector
Air edector
Inside f.w.g vaccum distillate method so it attain in easily boiling point inside f.w.g
Vaccum gauge for remove inside vaccum
F.w.g principle vaccum distillate
F w g classified into 3
Low pressure eveporator
Flash eveporator
Reverse osmosis
Eveporator connect with jcw 70-80°c
Condenser link with sea wather for phase change
Demister remove salt content and minute particles of vapor form
Salinometer salt defector below 1 ppm we use for fwg
Expansion tank yeduku sir adoda process teiryanum sir
Oru alavu correct ah sir ❤
Hello . Why we need keep sea water pressure from condenser in positive pressure . What is the reason to install gauge overs there ?
To check the heat transfer parameter and also we can gauge the condition of condenser sir...Hope this reply will satisfy your query..
Hello sir.. Good videos.. ✌🎉
I have one query.. Sir in fwg very strange thing happening... Jcw inlet is around 65 degree n outlet 80 degrees... Also when we are closing bypass more, production n shell temperature reducing..??
What can go wrong??
U can make ny whatsApp group for trouble shooting, so that we can get some instant ideas and help??
Thanks
Thanks for your good query.. really its a strange thing...
can you pls provide ma all parameters before and after with bypass valve completely closed.
Kindly try to renew thermometer and send the parameters..
Is there any drop in vacuum?
Thanks for you for giving an idea of opening a whataspp group for trouble shooting...vl do for sure sir..