How to connect Encoder with S7-1200 ? || High Speed Counter HSC || TIA PORTAL || Lesson#13

Поделиться
HTML-код
  • Опубликовано: 23 июл 2024
  • #Encoder #TIAPortal #Siemens #Simatic_manager #leaning #progamming
    Complete training series of Simatic Manager and TIA portal please check it out also
    Please subscribe to my channel
    Encoder with PLC
    using encoder with the PLC S7 1200
    00:00 Introduction
    00:22 What is Encoder ?
    00:48 wiring diagram of Encoder
    01:16 Encoder wiring with S7 1200 PLC
    02:07 Encoder programming in TIA Portal
    04:20 Testing Encoder program

Комментарии • 44

  • @hymdt
    @hymdt Год назад

    you saved our day with this information ... thanks

  • @botas82
    @botas82 3 года назад

    Great vídeo, thanks a lot.

  • @thomassaook7787
    @thomassaook7787 4 года назад +1

    simple & accurate

  • @medosust
    @medosust Год назад +1

    Very helpful especially wiring

  • @mahmudrajon9104
    @mahmudrajon9104 3 года назад

    very good work.

  • @ymmijjohnsson
    @ymmijjohnsson 6 месяцев назад

    keep up the good work. There are many channels with the Siemens tia portal, but not many that are as informative as yours

  • @allagomar6033
    @allagomar6033 3 года назад

    Thank you so much bro i wish to continu like this video

  • @rashidchibvuri2036
    @rashidchibvuri2036 2 месяца назад

    Great explanation sir thank you.

  • @nazmikaddora1457
    @nazmikaddora1457 3 года назад

    Thank you so much

  • @nirutg5130
    @nirutg5130 2 года назад

    Thank you very much

  • @tarekmohsen7572
    @tarekmohsen7572 3 года назад

    Thank you

  • @rokibhasan2823
    @rokibhasan2823 4 года назад

    Can i change the input in monitor mode without using encoder??

  • @gilbertopadovani
    @gilbertopadovani 4 месяца назад

    Thanks for the explanation.
    Could you tell me where to buy the Seiki CB2000-HC encoder? I tried searching but without success. Thanks in advance.

  • @electromecanica_automatismos
    @electromecanica_automatismos 2 года назад

    By the way...in this wiring diagram I suppose that your Rotary Encode is NPN output (If not --- PNP--- M (0V) must be connected to 1M.... that`s right?)

  • @pajur
    @pajur Месяц назад

    Why is Z signal connected to I0.2? Does it have any sense here? According to S7-1200 manual, only A/B signals are needed.

  • @shameehaajmal1517
    @shameehaajmal1517 2 года назад

    Great video! Can I know why all three encoder signal wires are connected to the PLC?

    • @EASYPLCTRAINING
      @EASYPLCTRAINING  2 года назад +1

      Good question! three wires to detect if the encoder is moving in CW or CCW direction

  • @sarpturker5034
    @sarpturker5034 3 года назад

    Good tutorial. But one think i cant figure out. Where is the Orange cable Z-phase I0.2? Cant see it in Hardware Inputs?

  • @yadavsaroj1657
    @yadavsaroj1657 3 года назад

    Sir please same program in omron plc cx-program

  • @ahmedrezk2281
    @ahmedrezk2281 3 года назад +2

    The jumpre on L+and1m error

  • @tourdhorizon97
    @tourdhorizon97 3 года назад +2

    2000 pulses per Revolution, how is it possible for this small encoder ????

  • @rincebaby145
    @rincebaby145 5 месяцев назад

    Nice video.but how we get reset input the encoder

  • @decentmkiza8570
    @decentmkiza8570 4 года назад

    Can you do a video of a stepper motor connection and programming

  • @muhammaddanishhameed9865
    @muhammaddanishhameed9865 3 года назад

    Bhai, encoder se motor ka rpm kis tarah calculate ka sakta hein siemens mein

  • @balajisekar2071
    @balajisekar2071 3 года назад

    How to connect two or more encoder in one plc

    • @EASYPLCTRAINING
      @EASYPLCTRAINING  3 года назад +1

      You can install encoder input cards with the plc

  • @MaterieUltimeUnofficialChannel
    @MaterieUltimeUnofficialChannel 4 года назад +1

    why +24V is connected to 0V?

  • @desifiedCanada
    @desifiedCanada Год назад

    How to reset count value ?

    • @EASYPLCTRAINING
      @EASYPLCTRAINING  Год назад +1

      Move zero in the data register

    • @desifiedCanada
      @desifiedCanada Год назад

      @@EASYPLCTRAINING is there any option for external reset ?

    • @EASYPLCTRAINING
      @EASYPLCTRAINING  Год назад +1

      Connect a push button with the PLC, use thus push button signal to move the zero to the encoder data register

    • @desifiedCanada
      @desifiedCanada Год назад

      @@EASYPLCTRAINING should we move zero in IW1000 or QW1000?

    • @ghouseahmed4u
      @ghouseahmed4u Год назад

      @@EASYPLCTRAINING can we do like this - "Since pulses are DInt format, after counter finishes counting until 2147483647, then can i move "1" to ID1000 directly, so that the cycle repeats?

  • @kingofthering1224
    @kingofthering1224 6 месяцев назад

    why the counter value reach out to 1700.....??? it must be 1500 only ??? I'm right

  • @peppealfano65
    @peppealfano65 3 года назад

    non si vede bene

  • @vorapobautomation9760
    @vorapobautomation9760 4 года назад

    How about S7-1500 HSC ?