OIL OIL ALL OVER THE PLACE

Поделиться
HTML-код
  • Опубликовано: 20 апр 2024
  • Well that was a fun one
    HVACR VIDEOS MERCH WEBSITE - www.hvacrvideos.com
    Please consider supporting my channel by
    Becoming a Patreon member - Patreon / hvacrvideos
    Becoming a RUclips channel member / @hvacrvideos
    By purchasing tools via my affiliate links below at TRUTECHTOOLS.COM and use the offer code BIGPICTURE to save 8% on your total purchase (exclusions apply)
    Visiting my website and purchasing merch www.hvacrvideos.com
    HVAC OVERTIME CHANNEL LINK - / hvacovertime
    Social Media
    Facebook / hvacr-videos
    Instagram / hvacrvideos
    For any inquiries please contact me at chris@hvacrvideos.com
    Mailing Address
    HVACR VIDEOS
    12523 LIMONITE AVE.
    440 - 184
    MIRA LOMA, CA. 91752

Комментарии • 98

  • @The98deville
    @The98deville 28 дней назад +138

    Oil leaking like it was a BMW

    • @arthouston7361
      @arthouston7361 27 дней назад +10

      Or a 4.0 L Jeep.

    • @Blasterxp
      @Blasterxp 27 дней назад +2

      Cool comment! Really like it

    • @stazeII
      @stazeII 27 дней назад +22

      Also doesn’t have any turn signals, so can confirm, BMW.

    • @JoeCdaYT
      @JoeCdaYT 27 дней назад

      More like an any vehicle that has not been maintained well.

    • @dashcamandy2242
      @dashcamandy2242 27 дней назад +2

      ​@@arthouston7361 As the owner of a 4.0L Jeep, and as someone who has worked on several 4.0L Jeeps, you're not wrong.
      Although, by some miracle, mine doesn't leak a drop! Previous owner put over $1,000 into making sure it didn't leak before I bought it two years ago. It's not a question of "IF" it'll start leaking, it's a question of "WHEN" and "WHERE" - but at least for now, I have one of the extremely rare non-leaking Jeeps.
      I've gone and jinxed myself, haven't I?

  • @keith_5584
    @keith_5584 27 дней назад +34

    Get that system a hotdog for all that mustard!

  • @uzlonewolf
    @uzlonewolf 27 дней назад +16

    Those all-in-one boxes/islands would probably be good ideas if they were designed as modules with repair in mind. One section has a problem? Just pull a few bolts and that section can be removed for easy repair or replacement. But of course that makes the initial purchase price much higher so they don't do it.

  • @HappilyHomicidalHooligan
    @HappilyHomicidalHooligan 27 дней назад +5

    If the Restaurant doesn't want to lift the rack to do a proper repair, is it possible to use a thick epoxy resin to coat the floor of the rack instead? Use a thick enough Epoxy and it should flow into the holes and plug them up, then set into a strong plastic sheet sealing the rotten area away from any water coming from the rack area itself such as when you're cleaning it...
    That won't be cheap, but it should cost a HELL of a lot less than lifting the entire rack to replace the rotted sheet metal would...and it would have the benefit of being done while the rack is running too...

  • @glenjones4404
    @glenjones4404 27 дней назад +4

    Frankenstein outdoor unit lol
    It needs a hundred oil traps as the pipe work falls down to the multitudes of evaps lol😂😂😂

  • @VC-Toronto
    @VC-Toronto 27 дней назад +9

    I'm amazed at the lack of food scraps in the reach in section!

  • @ThePowerofElectricity
    @ThePowerofElectricity 27 дней назад +25

    For these systems an oil separator in the discharge line seems like an idea to make the compressors last longer...
    Have it separate out a good part of the trapped oil and link it back to the suction with a capillary tube and cut-off solenoid for the pump-down.
    Considering how much time you spent on just this service call, it's likely cheaper to install these than just call you every other year. But hey, if the customer doesn't want to do it, it's more money for you later. Win-win.

    • @HVACRVIDEOS
      @HVACRVIDEOS  27 дней назад +10

      Yeah but to be fair it would likely plug up the return line because they don’t do good maintenance

    • @ThePowerofElectricity
      @ThePowerofElectricity 27 дней назад +7

      @@HVACRVIDEOS That is a very valid concern. Any added part is another possible point of failure.

  • @Paul-IE-Repairs
    @Paul-IE-Repairs 25 дней назад +4

    when that solenoid to Tee Joint cooled it shrunk and pulled back, hopefully there is still enough engagement @11:31 mark

  • @adamdomaciucet2105
    @adamdomaciucet2105 27 дней назад +8

    Oil separator, Chris... It would solve this, use either a piston with a pulsing solenoid or a small capillary with pump down cutoff solenoid. Catches something like 98% of the oil, which would not solve the problem but definitely delay the onset of the symptoms. Otherwise 10/10 vid.

  • @chloethelab
    @chloethelab 27 дней назад +15

    What's this chris struck oil dude ya gonna be rich as heck 😂 lol

  • @CHOMAHOMA
    @CHOMAHOMA 8 дней назад +1

    I have not finished it, but I ❤ this video. Great work. I also like the idea of using that wire brush for cleaning the copper before disassembling the component.

  • @JoeCdaYT
    @JoeCdaYT 27 дней назад +6

    A suggestion that I could make is to resolve the oil issue is to put a cap tube after the txv to the suction line after the sensing bulb. Make a p trap with the cap tube after the txv to let oil get trapped but still let a little refrigerant after it has cleared all the oil out. This is the engineering mind that I have going that says how to fix the issue. I have run into this same issue before with failed power heads even on box systems. More info for the other techs in the field to pickup on when they find things like this.

  • @davidefinland6886
    @davidefinland6886 27 дней назад +8

    Polishing the ...

  • @ronwade2206
    @ronwade2206 26 дней назад +2

    I love it, grind...grind... Darn it! 😅

  • @renzmathewsserit8115
    @renzmathewsserit8115 20 дней назад +1

    One of sensible comment at the last part of this video❤️

  • @fshn76
    @fshn76 27 дней назад +14

    Holy oil Batman.

  • @luisgarcia2863
    @luisgarcia2863 18 дней назад +1

    Like always great info Chris. Thanks from florida

  • @alext424
    @alext424 28 дней назад +15

    Great video Chris! I really appreciate your explanations in the closing words. 👍🏻👍🏻👍🏻

  • @R290s_biggest_fan
    @R290s_biggest_fan 27 дней назад +3

    There isn't enough refrigerant velocity through the txv when the powerhead is bad, traps the oil.

  • @terminator761
    @terminator761 27 дней назад +4

    A big issue might be, the txv entering on the bottom and the sucction leaving at the top. Back in trade school we talked about it because the refrigerent has to move up against gravity and the oil falls back inside and stays down, im pretty sure if enter from top end put a nice p trap in there it might fix the issue. But i know its a pain since you dont have any space in there

  • @jesseh5554
    @jesseh5554 27 дней назад +3

    gotta be honest, miss the sporlan intro. Quality, Integrity, Tradition.

    • @HVACRVIDEOS
      @HVACRVIDEOS  27 дней назад +3

      I needed a change after 900 videos with the same Intro

  • @Jilocasindragon
    @Jilocasindragon 26 дней назад +2

    You shaved! :D
    No, good job! Love seeing something that makes you guys go "Huhh.. interesting"

  • @petergriffin1906
    @petergriffin1906 27 дней назад +1

    Great job !

  • @danpresson
    @danpresson 28 дней назад +2

    Awesome video great info

  • @zekenzy6486
    @zekenzy6486 27 дней назад +1

    Great Video. Nice work and Good Job. Thank you for sharing

  • @thesilentonevictor
    @thesilentonevictor 27 дней назад

    Good troubleshooting Chris

  • @jefftrain68
    @jefftrain68 27 дней назад +1

    Thanks for the hat bro. Fits perfect.

  • @rockercover
    @rockercover 27 дней назад +3

    Send that system straight to the hospital. (Serious infection).

  • @Matt-ll1pd
    @Matt-ll1pd 23 дня назад

    Love the kitchen stuff!

  • @garypoplin4599
    @garypoplin4599 22 дня назад +1

    12:07 - Yeah. The boss always gets the easy TEV!

  • @Marklopez362
    @Marklopez362 27 дней назад +2

    We take care of a Kairak rack for one of our customers. I’m dreading the day I have to make repairs like this in their extremely busy line. So far since I’ve been with this company (1.5 years) it’s dumped the charge 3 times from lines rubbing out. They refuse to do any maintenance.

  • @Josh.SPublishingTeam2024
    @Josh.SPublishingTeam2024 24 дня назад

    OMG! So much oil coming out, that compressor is done for!Awesome video! Be careful working on these units!

  • @jonfitz8280
    @jonfitz8280 26 дней назад +2

    It sucks trying to find a job in HVAC I like this, I like bringing people comfort and what better way than airflow and heat displacement

  • @JW-me2po
    @JW-me2po 27 дней назад +5

    Those pan chillers are a nightmare! Drains constantly clog and fan motors burn out.

    • @HVACRVIDEOS
      @HVACRVIDEOS  27 дней назад +1

      Funny I’ve got a call on one of those pan chillers freezing up at another store tomorrow

    • @JW-me2po
      @JW-me2po 27 дней назад +1

      Oh those are especially fun, when the whole drain line freezes. Had to make a 3/8 hose out of vinyl tubing that I use to run hot water while snaking down drain line.

    • @HVACRVIDEOS
      @HVACRVIDEOS  27 дней назад

      Yeah I do the same, I defrost the drain line while using a shop vac to remove the water first than the pan chiller gets defrosted last if it’s not already defrosted

  • @alekmartinez3109
    @alekmartinez3109 13 дней назад +1

    Pumping a scroll compressor down to 2 psi is a no no.

  • @bensreferigeration
    @bensreferigeration 27 дней назад +2

    Nice job.

  • @Arides2010
    @Arides2010 27 дней назад +3

    Out of curiosity: What kind of gaskets are in the solenoid valve you brazed in? The valves our company usually uses have rubber o-rings that get roasted if you do not cool the valve during brazing or disassemble it before hand… great video as always. Keep it up.

    • @HVACRVIDEOS
      @HVACRVIDEOS  27 дней назад +1

      That valve is too small to really protect, just gotta go for it hot and fast and cool it afterwards

  • @DelticEngine
    @DelticEngine 26 дней назад +1

    Awesome in-depth video, Chris, with great team work. You put a lot into it going through everything and covering the important details. It was one thing to see all that oil come oil which makes you feel sorry for the compressor, but it was quite another to see your new 'look' when it came to the closing commentary! Is compressor oil actually from the proverbial 'fountain of youth' (which would explain the high cost of compressor oil as well as why HVACRs never seem to get old or at least age much more slowly), or does it make your make your hair fall out (which would explain the lack of facial hair and cap)?

  • @jtbiberdorf
    @jtbiberdorf 26 дней назад +1

    Doesn’t the oil coat the inside of the pipes and prevent heat transfer while the refrigerant still goes through the coil? I don’t think it traps refrigerant in the evaporator.

  • @jasontexter1721
    @jasontexter1721 27 дней назад +1

    I had a contractor install a dual evap in a walk in and they left the individual temp controls install so only one evap would run and rhe other would accumulate all the damn oil so id lose all the oil in the compressor. I had to twin them. Running a compressor ar half capacity with large line sets is a recipe for disaster

  • @brushben22
    @brushben22 25 дней назад +1

    Add oil to that compressor for sure lol

  • @jasontexter1721
    @jasontexter1721 27 дней назад +1

    Discharge oil separator like they use in ultra low temp refrigeration is a fantastic idea if they're gonna do stupid stuff like having the suction on the top instead of the bottom

    • @alejandrozometa1951
      @alejandrozometa1951 27 дней назад

      Yeah but like on a real rack you need an oil separator oil differential valve and a oil reservoir

  • @dkd1228
    @dkd1228 27 дней назад +4

    "The road to hell is paved with good intentions". Great educational video!

  • @matth5309
    @matth5309 27 дней назад +1

    Would using the exhaust of the vacuum to blow all the water out work? That way you wouldn’t damage your vacuum.

  • @xisorryexpertix8042
    @xisorryexpertix8042 27 дней назад

    Delfield coils do this a lot.

  • @DWAYNE2ism
    @DWAYNE2ism 27 дней назад +1

    Wow

  • @jo6520
    @jo6520 27 дней назад +1

    What do you think about the new R454b that will replace 404A?

  • @makinbac0n
    @makinbac0n 27 дней назад +1

    Shows the process of troubleshooting a technician has to do when the problem isn't obvious.

  • @yinggamer7762
    @yinggamer7762 26 дней назад +1

    Brazing a2l might be sus?

  • @Colt-wr6wx
    @Colt-wr6wx 27 дней назад +1

    Question... was there also predator blood/ leak detector in that system?. Oil looked suspicious to me..

  • @taylorj9920
    @taylorj9920 27 дней назад +2

    Ole pf and their messy setups

  • @SupremeRuleroftheWorld
    @SupremeRuleroftheWorld 27 дней назад

    did not know land rover also made coolers.

  • @johnwalker890
    @johnwalker890 27 дней назад

    Good job Chris, Shaven face for a change.

  • @firstknocked8767
    @firstknocked8767 27 дней назад

    Looks like a PF changs

  • @johnhammon703
    @johnhammon703 25 дней назад +2

    I hope you know the risks of brazing with those types of gloves on. You should be using leather and not something that can melt to your hand.
    Just FYI. Safety first.

  • @MinhTran-cq3vo
    @MinhTran-cq3vo 28 дней назад +3

    😋

  • @hunterswanson5220
    @hunterswanson5220 27 дней назад +1

    So looking by the setup looks like a P.F. Chang’s. We do work for them here in Chattanooga. They have almost identical setup with custom built stuff and condensing unit is in rack. Ended up 7/9 of their evaporation coils had leaks. We ended up going back with all new heat craft coils since somehow the coils couldn’t be sourced. Leaks were so bad we were going back every month to top off charge

    • @taylorj9920
      @taylorj9920 27 дней назад

      They were sourcing those original coils from a vendor that was getting them custom specd and built in bulk orders for those coil assemblies they we're installing during their retrofit shutdowns

  • @carlyleworkman1928
    @carlyleworkman1928 27 дней назад

    👍🏿

  • @steveblake8766
    @steveblake8766 27 дней назад +1

    74 thumbs up

  • @stillthakoolest
    @stillthakoolest 27 дней назад +2

    Build quality is just sad on these units. But then again customer doesnt want to pay for quality so true wont build anything decent and you end up fixing this crap.

  • @TheBlu04
    @TheBlu04 27 дней назад +1

    I don't understand how people can let their equipment get to such a terrible status, I know there's been worse but this is bad enough for a total replacement of the system (In my eyes at least)

  • @I_am_Allan
    @I_am_Allan 27 дней назад +1

    Is that mineral oil?

    • @HVACRVIDEOS
      @HVACRVIDEOS  27 дней назад +1

      No it’s dirty overheated Poe oil

    • @I_am_Allan
      @I_am_Allan 27 дней назад +1

      @@HVACRVIDEOS at first I thought it was Canola oil... then maybe 5W15 ... then settled on Mineral oil.
      Alas, I was wrong on all three counts.

  • @malambamichael8565
    @malambamichael8565 26 дней назад +1

    ❤❤👍👍👍👂🇿🇲

  • @cayden9224
    @cayden9224 27 дней назад +3

    How are there always comments from before the video was posted?

    • @PedroHenrique-cu6fq
      @PedroHenrique-cu6fq 27 дней назад +1

      just youtube bugs

    • @CalebBlackhand
      @CalebBlackhand 27 дней назад +3

      Early video access for channel members

    • @MoseyingFan
      @MoseyingFan 27 дней назад +2

      Try looking in the video description, I'll say Patreon.

    • @HVACRVIDEOS
      @HVACRVIDEOS  27 дней назад +5

      The channel members typically get access to the video before the public

  • @rafaelgomez4304
    @rafaelgomez4304 27 дней назад +1

    Custom islands are the worst!

  • @shifter8207
    @shifter8207 27 дней назад +1

    If the roof is leaking I would say in that situation a diesel powered air compressor would be a better option ? No?

  • @UhOhUmm
    @UhOhUmm 27 дней назад +3

    Man that electrical is ugly looking. I guess as long as it's not burning it's fine.

    • @HVACRVIDEOS
      @HVACRVIDEOS  27 дней назад +1

      Yeah I would love to make it look pretty but the customer isn’t too interested in me doing that….

  • @2centsbear638
    @2centsbear638 27 дней назад +2

    The beard! Noooooooo

  • @suezq74
    @suezq74 27 дней назад +2

    Oh dear heavens that’s bad! The compressor needs oil really bad! Compressor without oil: *seizes up* *ded* did you like the joke HVACR VIDEOS? - Riley

  • @raydoactive
    @raydoactive 27 дней назад +1

    “…And the sight glass is clear!” 🫡