Capillary Tube Data Chart for R290, R134a, R600a, R404a

Поделиться
HTML-код
  • Опубликовано: 19 янв 2025

Комментарии • 89

  • @rashidshaikh7171
    @rashidshaikh7171 7 месяцев назад +1

    Mr. F. K. Sir you is heartly teaching, suggesting technically guidence to HVAC job worker and students thanks

    • @FKmechofficial
      @FKmechofficial  7 месяцев назад

      Many many thanks Dear brother ❣️

  • @mansarhayat4543
    @mansarhayat4543 7 месяцев назад +1

    اللہ پاک فرمان بھای کی زنداگی کرے اس طرح کے لوگ بہت کم جو فری میں سکھا رہے ہے

  • @jilubhai5255
    @jilubhai5255 7 месяцев назад +1

    Masha Allah beutiful video Bhai jann 💐💐💐💐

  • @AzmatKhan-d2n
    @AzmatKhan-d2n 7 месяцев назад +2

    Good job 👍👍👍

  • @gpsjoybhai273
    @gpsjoybhai273 7 месяцев назад +3

    deep freez ka capillry deta bataye sir ji

  • @swalehmuhammad2428
    @swalehmuhammad2428 7 месяцев назад +1

    Dear sir mujhe ya video achi lagi ap nay maree ak mushkil hal nikal diya Allah ka hukam say laki ak or masla ya hay ka

  • @BilalKhan-ss2tp
    @BilalKhan-ss2tp 7 месяцев назад +2

    Nice video sir ji

  • @obaidish
    @obaidish 7 месяцев назад +1

    Mashallah very nice video sir

  • @kashmirrokerz7889
    @kashmirrokerz7889 7 месяцев назад +2

    Sir deep freezer ki capilary kitne hone chahye

    • @FKmechofficial
      @FKmechofficial  7 месяцев назад +2

      Next video me deep freezer Ka data chart banawonga Insha Allah

  • @jorgealbertoretro4821
    @jorgealbertoretro4821 7 месяцев назад +1

    I´m from Mexico . . . Excellent information🙂

  • @patelbrijal241
    @patelbrijal241 7 месяцев назад +1

    Sir fan cool conditioner & fan heat exchangr evaporator me bhi ae chalega

    • @FKmechofficial
      @FKmechofficial  7 месяцев назад

      Kiya ap air ventilator ki baat kar rahe ho. ?

    • @patelbrijal241
      @patelbrijal241 7 месяцев назад +1

      @@FKmechofficial deep freeze Capillary

    • @FKmechofficial
      @FKmechofficial  7 месяцев назад +2

      @@patelbrijal241 Next video me brother ❤️

    • @patelbrijal241
      @patelbrijal241 7 месяцев назад

      ​@@FKmechofficial ok sir

  • @starseven-f6x
    @starseven-f6x 7 месяцев назад +1

    deep freezer ma be kya yai deta use kya ja skta ha ya us k ala sy calculation ho gi ??

    • @FKmechofficial
      @FKmechofficial  7 месяцев назад

      No Dear, Deep freezer me data tora sa change hota hai

  • @preetdatta5353
    @preetdatta5353 7 месяцев назад +1

    Very informative ℹ️👍🏽

  • @TheAkash2818
    @TheAkash2818 7 месяцев назад +1

    Great sir ji 👍

  • @prakashgotame8875
    @prakashgotame8875 7 месяцев назад +1

    Good information sir

  • @hajmohamed3374
    @hajmohamed3374 7 месяцев назад +2

    Sir, visi cooler, bottle cooler capillary data videos please.

  • @keyurdabhi2340
    @keyurdabhi2340 7 месяцев назад

    hi sir,
    Your channel is a very good source of refrigeration knowledge. Thank you for all the knowledge.
    condensing & evaporating temperature ka data kaise decide karte hai?
    Kya evaporating temperature is minimum temperature of the system given by system manufacturer?
    Condensing temperature kaise decide kare?
    Aur sir ek aur detail video banaye ki size of capillary & condenser pipe & length kaise decide kare compressor e hisab se ? Please....

    • @FKmechofficial
      @FKmechofficial  7 месяцев назад

      The condenser & evaporator temp: is decided by manufacturer as per requirement of the unit using in specific conditions,
      Jaise ap kisi AC unit ke zariye agar room temp: 16⁰C tk maintain karna chahe, to manufacturer usss AC unit ka evaporator temp: taqreeban -5 tk rake ga,
      Isssi Tarah isss unit ka coil temp: taqreeban 0⁰C,
      Isssi tarah isss unit ka grill temp: taqreeban 9⁰C,
      Awr room temp: 16⁰C maintain hoga

    • @keyurdabhi2340
      @keyurdabhi2340 7 месяцев назад +1

      @@FKmechofficial sir ji,
      agar me nayi system design karna chahu to ye sab details kis basis pe decide kar sakte hai?

    • @FKmechofficial
      @FKmechofficial  7 месяцев назад

      @@keyurdabhi2340 Heat load calculation awr Refrigerant PH chart se

  • @furqanhashim3249
    @furqanhashim3249 2 месяца назад

    R 600 compressr ki capilary presure kitna hota ha .

  • @aayushlanjhekar3174
    @aayushlanjhekar3174 Месяц назад

    Sir R404a gas ka back pressure kitna rakhna chahiye deepfrizer me -20.c temperature vala hai

  • @nayanjagirdar8408
    @nayanjagirdar8408 7 месяцев назад +1

    Nice sir 👌👍

  • @umairshaikh3859
    @umairshaikh3859 4 месяца назад +1

    Chillur me kon si refrigerator charge hoti h

    • @FKmechofficial
      @FKmechofficial  4 месяца назад

      @@umairshaikh3859 R22, 134a, 407c, 410a

  • @swalehmuhammad2428
    @swalehmuhammad2428 7 месяцев назад +2

    Manay single door deep freezer ma capillary change ki hay or wo 134 ka system tha us ma manay 290 dali hay lakin ice nahi arahi sido per or return bhe achay say arahi hay back presdure 8 hay

    • @FKmechofficial
      @FKmechofficial  7 месяцев назад +1

      Agar unit me koyi awr issue nhi hai, to pir back pressure 12 SE 15 tk rak Lo bhai

    • @FKmechofficial
      @FKmechofficial  7 месяцев назад +1

      Leken R290 gas liquid halat me charge karna chahye

    • @swalehmuhammad2428
      @swalehmuhammad2428 7 месяцев назад +1

      Sir g apki sari bat sahi hay lakin capillary .32 ki dali hay or pressure bhe 15 kiya lakin phir bhe sido per ice nahi arahi poori rat ma ak katora bhe nhi jamaya kiya karna chahiya

    • @FKmechofficial
      @FKmechofficial  7 месяцев назад

      @@swalehmuhammad2428 condenser ki temp: IN our OUT kiya hain

    • @swalehmuhammad2428
      @swalehmuhammad2428 7 месяцев назад +1

      @@FKmechofficial sir temp meter nahi hay is liya condensor ka temp note nhi kiya

  • @meditationbiswas3741
    @meditationbiswas3741 7 месяцев назад +1

    Excellent Sir. Please give an idea of what is the evaporator copper tube length of 1/4" dia . And what will be the condenser length of 3/16" dia for a 1/4 Compresso and a capillary tube of 0.032.

    • @FKmechofficial
      @FKmechofficial  7 месяцев назад

      Evaporator length 50 ~ 60 ft,
      Condenser length 75 ft

  • @MIJANURRAHMAN-xr2ew
    @MIJANURRAHMAN-xr2ew 4 месяца назад +1

    Thank you brother is very useful.♥️♥️♥️

  • @abdulraheemthebo8212
    @abdulraheemthebo8212 7 месяцев назад +1

    Sir agr hum ek sada compressor ki jagah ek inverter compressor use karen to us k liye hamen kon c cheezen dekhni parengi

    • @FKmechofficial
      @FKmechofficial  7 месяцев назад

      Bhai hr aik chiz dekni hai, condenser evaporator, capillary tube but most important capillary tube ko zaroor compressor ke mutabiq honi chahye

    • @abdulraheemthebo8212
      @abdulraheemthebo8212 7 месяцев назад +1

      Sir agr time miljaey to is per ek rehnumai wali video banaden plz

    • @FKmechofficial
      @FKmechofficial  7 месяцев назад

      @@abdulraheemthebo8212 Insha Allah zaroor

    • @abdulraheemthebo8212
      @abdulraheemthebo8212 7 месяцев назад +1

      Thank you very much sir may allah bless you long and healthy life❤❤❤❤❤

  • @nidaassociates7441
    @nidaassociates7441 7 месяцев назад +2

    Ek aur refrigerant hai but apne nahin likha hydrocarbo

  • @laljidhundhalva8702
    @laljidhundhalva8702 10 дней назад

    3 ton r404a capillary use kariye

  • @ractoday6688
    @ractoday6688 3 месяца назад +2

    nice

  • @asadkhan9887
    @asadkhan9887 7 месяцев назад +1

    Assalamualaikum Bhai me Karachi se hon ap se mulaqat karna chahta hon mera ice cream ka kam kuch mashwara karna he

    • @FKmechofficial
      @FKmechofficial  7 месяцев назад

      Wa Alaikumussalam,
      G Janab me Bannu se hon.
      Abhi issi waqt mera Ghar Taxila me hai.
      Awr currently me Haripur me Technical college me Job kar raha hon

  • @mohanv9483
    @mohanv9483 7 месяцев назад +1

    Lbh means sir

    • @FKmechofficial
      @FKmechofficial  7 месяцев назад +1

      LBP means, low back pressure,
      Evaporator temp: -5⁰C ke below

    • @mohanv9483
      @mohanv9483 7 месяцев назад +1

      @@FKmechofficial thank you sir

  • @liveupinc
    @liveupinc 20 дней назад +1

    good

  • @RazwanSoomro-h3i
    @RazwanSoomro-h3i 7 месяцев назад +1

    Nic

  • @swalehmuhammad2428
    @swalehmuhammad2428 7 месяцев назад +1

    Please air rehnumai farmay

  • @meditationbiswas3741
    @meditationbiswas3741 7 месяцев назад +1

    The condenser made of iron

    • @FKmechofficial
      @FKmechofficial  7 месяцев назад

      In mostly refrigerators, condenser made of iron and In air conditioners condenser made of copper

  • @Ganeshkaushalp07
    @Ganeshkaushalp07 7 месяцев назад

    Shukriya bhai

  • @msaifali6294
    @msaifali6294 6 месяцев назад

    MashAllah

  • @abdulhaqgull
    @abdulhaqgull Месяц назад

    ❤❤❤❤❤❤

  • @liveupinc
    @liveupinc 6 месяцев назад +1

    tooo good word sir