Without battery kya ye inverter rat ko chalega yan band hojayega? Kyun ko rt ko source single hojayegi mtlb sirf grid? Kya grid ki available hone ki surat m chalta rehta hai?
Great! ab nitrox is qabil hua hai k khareeda jaye, bagair battery! Mere paas 9 hours daily load shedding hoti hai. aur din mein pora ghar ground + 1 5 ghante chalta hai BAGAIR BATTERY AUR BAGAIR GRID. 3 non inverter fridges, 3 desktop computer, 1 automatic washing machine. lagta hai generator chal raha hai. sirf submersible pump ka torque nahin uthta. baqi sab chalta hai. Ager cloud hote hain tu torque load yani fridge k uthne mein thora masla banta hai, lekin aik aik kar k fridge uth jate hain. kabhi kabhi trip b ho jata hai inverter heavy cloud ki waja se, lekin it is not an issue. Aap bagair battery k b solar use kar sakte hain generator ki tarha din mein. mere paas 4.6 kw jinko ntype k panels hain aur Daxtromn 6.2 kw inverter hai jo k bagair battery k chalta hai. grid attached hoti hai. Lekin load jitna b ho, grid se 76w se ziada nahin leta mera inverter ager enough solar available ho.
Aoa I have installed 6kw nitrox without batteries so solar + wapda, it keeps tripping with AC_noutility error randomly. Grid voltages are stable. it trips even with zero load running on it. what could be the issue?
Ye without battery waaly Inverex single source per b chalty hen per masla ye Hy k jab hum single source ( sirf solar panels without battery) inverter use kerty hen to humen is baat Ka khayal rakhna hota Hy k hum jitna b load inverter per daalen wo humaari solar panels us din aur time jitni electricity bana rahy hun us se zyada na hojaay, jis waqt b gher ka load solar panels ki power generation se zyada hoga ( chaahy wo AC/Fridge k compressor k starting men uthny wala max load kion na ho ) to inverter foran OFF hojaaega. Yaad rahy k normal AC ager 1800watts per chalty hen to unka compressor starting Ka jhhatka 3000watt ya is SE b zyada hojaata Hy jiski waja se Without batteries wala inverter OFF hojaata Hy kion k us waqt hamary solar panels 3000+ electricity generat Nahi Ker rahy hoty, aur yahi baat logoon ko samajh Nahi aati.
@@AGradeSolarKarachi I have Inverex Aerox Pluse 3.2kw inverter and I have run it many times on single source ( Only Solar Panels Without Batteries ) even I have run 2 full size refrigerators + 3 Wapda fans and 5-6 LED bulbs on it without batteries without any fault errors. After 3 years Alhamdulillah I am still using that same system with same inverter 🙏
Bhai as u told k hami 2 inputs chahyain either Solar+WAPDA or Solar+Batteries. Tou is inverter main ya koi or aisa inverter ha jo One input means only Solar py kaam kary day time ma jab loadsheding ho or wapda available na ho?
Aoa sir manay recently Inverex Nitrox 8kv with (4) Inverex 220ah Batteries install ki hn .First day pe manay battery test kia tha battery ko full 100% charge kr k almost load under (800-600) watt thaa or isny mashallah sy 12 hours ka backup diaa phir subha solar sy battery charge hogayi thi full again raat ko battery sahi chalri thii lekin jesy hi below 40% pe ayi F56 ka error ana shuru hogaya ?? User manual ma parha toh likha k battery ka issue hai jab k batteries bilkul new hain or puri raat aram sy nikalti hai lekin 40-30% F56 ka error aajata hai .Please answer karein iska solution (Thanks You) Note : Mere pass wabda available hai lekin ma use nhi kra sb solar sy chalra hai
Kabhi Test NehinKiya Sir Earth Leckage mein Ground Earth Lagana Perta Hai Eak Site Per Use Kiya Tha To Grid Charging per tripng kerta tha isliye utar diya
Sir I have installed same system,same batteries but with 610 n type 6 panels for my shop, with normal load 500 to 600 watts only in day till 6pm and i turn on wapda 5.30 to7 pm only then wapda off and load goes to 200watts whole night but it hardly runs whole night some times it turns off at 6am Battery discharges vey fast Plz any solutions
Sir as nitrox is expensive can we use veyron 2.5? And i dont want batteries as very rarely there is load shedding so is veyron as good as nitrox . . Plus can we use them with generator if there is load shedding
❗U cannot run 2.5 veyron without batteries ✅ I suggest you to buy epever 3 kw cost 167000 as best solar inverter without battery and even ✅ if u will installed 8 panels u dont need wapda or KElectric either
@@anistanveer1298 on grid inverters are only used for selling electricity (Net Metering) They Just Export Electricity - On the other hand hybrid inverters have all qualities they support home load with the help of batteries even if grid is not available - their working pattern is Solar + Batteries OR Solar + Grid
Good video. Two questions; (1) since this inverter requires two sources at least, so it must have either KElectric+Solar OR Solar+Battery (when KElectric is gone). That means, it will start draining batteries for all the load at that time when KElectric is absent and solar generation is low or none? (2) If batteries are not connected and we are running with KElectric+Solar and KElectric becomes unavailable, the load will shutdown no matter if solar generation is more than the load?
✅ You have answered your own questions. ✅ If there is no electricity, the solar system will shut down ✅ Any two sources must be present to keep the solar system working
❤ arsalan Bhai Lagta ha fronus inverters Ka Kam ab ap Nahi kr rahy hen. Aur plz kbhi ek video breakers ki performance pe bi bna ke dikha den ke Kia breakers kbhi trip bi hotey hen . Kunke breakers Ka koi standard forum hamari country mn ha nahi
Assalam Walekum bhai mujhe ek Mahina Hua Hai nitrox per4 panel jinko 550 wale Lagaye hue lekin Aaj Tak Mera inverter 1350 what Tak Nahin Gaya bhai rahnumai farmao masale Ka Hal bataiyega
@@ghayassghayass8582 South 180° Hona Lazmi Hai Majbori Mein 200° ya 220° South West Ki Teraf Ja Sekta Hai - Tilt Angle 22° Se 28° Ke Ander Rehna Zarori Hai
@@AGradeSolarKarachi Sir typing mistake, 2024 ka jo new model ha nitrox 3 KW wala wo without battery work karaga, Or Starting ma 3️⃣ solar plates 575 watts per run ho jayega?
I want to install solar system in school . Building is open only in day time. I think k electric load presently is about 13 kilowatt. Need your opinion. Loaction is karachi.
Koi bhai bta sakta hai mere pass nitorx 3kw inverter hai voltage protector laga hoa jaisey hai wapda sey 251v hotey hain inverter wapda cutt off kr deta hai.iss ki kya setting krien jis sey inverter wapda cutt off na krey please help.
میرے بھائی اگر آپکا انوریکس کے ساتھ کوئی مسئلہ ہے یا کلیم کا کوئی اشیو ہے تو سروس سینٹر جائیں۔ ہم پراڈیکٹ کسٹومر کی چوائیس پر لگاتے ہیں۔ آپکا کا جو بھی جینئین مسئلہ ہے مکمل بتائیں تاکہ دوسرے کسٹومرز کو رہنمائی مل سکے۔ ایسے ادھورے اور بے تکے الزمات ہم پر کیوں لگا رہے ہیں۔
MASHALLAH amazing, great job
Without battery kya ye inverter rat ko chalega yan band hojayega? Kyun ko rt ko source single hojayegi mtlb sirf grid? Kya grid ki available hone ki surat m chalta rehta hai?
Great! ab nitrox is qabil hua hai k khareeda jaye, bagair battery!
Mere paas 9 hours daily load shedding hoti hai. aur din mein pora ghar ground + 1 5 ghante chalta hai BAGAIR BATTERY AUR BAGAIR GRID. 3 non inverter fridges, 3 desktop computer, 1 automatic washing machine. lagta hai generator chal raha hai. sirf submersible pump ka torque nahin uthta. baqi sab chalta hai. Ager cloud hote hain tu torque load yani fridge k uthne mein thora masla banta hai, lekin aik aik kar k fridge uth jate hain. kabhi kabhi trip b ho jata hai inverter heavy cloud ki waja se, lekin it is not an issue.
Aap bagair battery k b solar use kar sakte hain generator ki tarha din mein. mere paas 4.6 kw jinko ntype k panels hain aur Daxtromn 6.2 kw inverter hai jo k bagair battery k chalta hai. grid attached hoti hai. Lekin load jitna b ho, grid se 76w se ziada nahin leta mera inverter ager enough solar available ho.
yar ye to phr Nitrox se b acha hai,....load shading me without battery ka experience battyen....trip ktny % load pe hota?....
Masha allah good job
ما شآء اللّٰــہ !
بہت خوب !
Mashallah Behtreen ❤
Well done 💯 arsalan Bhai
Good information
3kw k sath netmetring kya ho sakti hai kya
jo DB apne use ki hy uski price brayen or wo kahan se milegi wo bhi btayen...
MashAllah good job
Aoa I have installed 6kw nitrox without batteries so solar + wapda, it keeps tripping with AC_noutility error randomly. Grid voltages are stable. it trips even with zero load running on it. what could be the issue?
inka load 3kw hy to Aap 6 panel suggest kryn...
Ye without battery waaly Inverex single source per b chalty hen per masla ye Hy k jab hum single source ( sirf solar panels without battery) inverter use kerty hen to humen is baat Ka khayal rakhna hota Hy k hum jitna b load inverter per daalen wo humaari solar panels us din aur time jitni electricity bana rahy hun us se zyada na hojaay, jis waqt b gher ka load solar panels ki power generation se zyada hoga ( chaahy wo AC/Fridge k compressor k starting men uthny wala max load kion na ho ) to inverter foran OFF hojaaega. Yaad rahy k normal AC ager 1800watts per chalty hen to unka compressor starting Ka jhhatka 3000watt ya is SE b zyada hojaata Hy jiski waja se Without batteries wala inverter OFF hojaata Hy kion k us waqt hamary solar panels 3000+ electricity generat Nahi Ker rahy hoty, aur yahi baat logoon ko samajh Nahi aati.
Nitrox Cannot Be operated on single saource
@@AGradeSolarKarachi I have Inverex Aerox Pluse 3.2kw inverter and I have run it many times on single source ( Only Solar Panels Without Batteries ) even I have run 2 full size refrigerators + 3 Wapda fans and 5-6 LED bulbs on it without batteries without any fault errors. After 3 years Alhamdulillah I am still using that same system with same inverter 🙏
Sir ap yeh bataien sab se best inverter 4kwa main.konsa hai
ip65 mein to eak hei hai Nitrox - baqui 4KW mein voltronic ka kisi bhi brand ka le sekte hain ip21 ya phir Epever per aa jayain
Assalamu alaikum inverx nitorx6kv ke sath 100 empier ki for battery lagai ho to unki setting kaise karen
Good
Nice
Bhai as u told k hami 2 inputs chahyain either Solar+WAPDA or Solar+Batteries. Tou is inverter main ya koi or aisa inverter ha jo One input means only Solar py kaam kary day time ma jab loadsheding ho or wapda available na ho?
majority ip21 solar inverters work kartey han without battery or grid..leken better functioning k lye grid/battery honi chaiyee
Super
Bahtreen
Mashaallah great job kia price hay aj mal 3 kv ke
270 Black Market
270 nitrox 3kw inverter?
Night m agr wapda nhn to kya mtlb battery backup nhn de gi ? Phir hybird aur ongrid m kya fark hua
Ayp Apne Load Ke Hissab Se Batteries Lagayain Ge to 24 Chele ga - Batteries Kam hain to phir unko charging ki zerorat humesha rehe ghi
Sir is ke saath jinko N type 580 watt ke 6 penal laga sakty hein ( 580× 6=3480 watts )
✅ Yes U Can Attach
Aoa sir manay recently Inverex Nitrox 8kv with (4) Inverex 220ah Batteries install ki hn .First day pe manay battery test kia tha battery ko full 100% charge kr k almost load under (800-600) watt thaa or isny mashallah sy 12 hours ka backup diaa phir subha solar sy battery charge hogayi thi full again raat ko battery sahi chalri thii lekin jesy hi below 40% pe ayi F56 ka error ana shuru hogaya ?? User manual ma parha toh likha k battery ka issue hai jab k batteries bilkul new hain or puri raat aram sy nikalti hai lekin 40-30% F56 ka error aajata hai .Please answer karein iska solution (Thanks You)
Note : Mere pass wabda available hai lekin ma use nhi kra sb solar sy chalra hai
Ayp nein programing match ki hai is video se
Salam.sir ek video (system work mode) k ander is option time to use ki bhi banaye.aur agar apk pas mojood hai to share karain.
Very good work, keep it up. Your cell
03433477786
Nitrox inverex ke sath minimum 12v ke kitni batteries lagayen to day time mein ke jane pe bhi production hoti rahe. Bhale backup na ho.
100 Wali 2 Batteries
Kaya ip65 inverter ma erth leakage protection hoti ha ya inverter per earth leakage breaker Kam kertay haan ager grid connect na ho
Kabhi Test NehinKiya Sir Earth Leckage mein Ground Earth Lagana Perta Hai Eak Site Per Use Kiya Tha To Grid Charging per tripng kerta tha isliye utar diya
@@AGradeSolarKarachi sir inverter Kay output per lagayeen ager safety Kay Liya
Sir I have installed same system,same batteries but with 610 n type 6 panels for my shop, with normal load 500 to 600 watts only in day till 6pm and i turn on wapda 5.30 to7 pm only then wapda off and load goes to 200watts whole night but it hardly runs whole night some times it turns off at 6am
Battery discharges vey fast
Plz any solutions
Batteries type and ah ??? Company
Phonix 1800 tubler 2
?
Sir as nitrox is expensive can we use veyron 2.5? And i dont want batteries as very rarely there is load shedding so is veyron as good as nitrox . . Plus can we use them with generator if there is load shedding
❗U cannot run 2.5 veyron without batteries
✅ I suggest you to buy epever 3 kw cost 167000 as best solar inverter without battery and even ✅ if u will installed 8 panels u dont need wapda or KElectric either
@@AGradeSolarKarachi jazakAllah sir will look for epever . . But veyron 2 series 2.5 says work without batteries.
Bhai price Kya nitrox ke 3kv
one question , my supply is 3 phase , all invertors are single phase then how they work
All Inverters ???? means qty
Kia 6 or 8 kw inverter with out batteries and wapda work kar sakata hay M iqbal
Yes - Bilkul Lakin Saath Wapda On Honi Lazmi Hai
Liquid battery per chal jaaiga hy?
✅ جی بلکل ❗ اگر پیسے بچانے ہیں تو بھی چھوٹی ٹیوبلر بیٹری کا استعمال کریں۔
3 min baad system reactive honay per ap ne inverter dikhaya he nahi.
Sir sargodha fasco pa 3 phase wapda sharing ha to ya udar to kam nai kra ga
Single phase per kam kere ga
ap ny bola k new series mai without battery chalay ga to humain kesy pata chalay ga k new series kon sa hai
❗Abhi New Series Hei Available Hai Market Mein
Sir same yehi panel ki prise kia hai 4 panel sir aur inverter 3kw IP 65 wala in sub ki final prise batain
Is Project Ki Cost Subha Description mein Add Ker Dun Ga
What is your opinion about Huawei inverter?
✅ Hybrid Inverter Huawei Mein Kub Aya ???? Its OnGrid Top Brand
Will you please explain what is the difference between hybrid and on grid.
@@anistanveer1298 on grid inverters are only used for selling electricity (Net Metering) They Just Export Electricity - On the other hand hybrid inverters have all qualities they support home load with the help of batteries even if grid is not available - their working pattern is Solar + Batteries OR Solar + Grid
@@AGradeSolarKarachi which hybrid inverter is best?
Good video. Two questions; (1) since this inverter requires two sources at least, so it must have either KElectric+Solar OR Solar+Battery (when KElectric is gone). That means, it will start draining batteries for all the load at that time when KElectric is absent and solar generation is low or none? (2) If batteries are not connected and we are running with KElectric+Solar and KElectric becomes unavailable, the load will shutdown no matter if solar generation is more than the load?
✅ You have answered your own questions. ✅ If there is no electricity, the solar system will shut down ✅ Any two sources must be present to keep the solar system working
Jinko n type 570 waly 8 panel lga skty hn ya ni?
N Type 7 Panels
N type 7 panel ktni watt ke maximum generation kr k de skta h kindly ye bta den summer ma?
@@HammadAli-os8uh Approx 3.2 KW
3kv notrox controller kay sath price kia hay
✅ Check Video Description
❤ arsalan Bhai Lagta ha fronus inverters Ka Kam ab ap Nahi kr rahy hen. Aur plz kbhi ek video breakers ki performance pe bi bna ke dikha den ke Kia breakers kbhi trip bi hotey hen . Kunke breakers Ka koi standard forum hamari country mn ha nahi
✅ Fronus ko FilHaal @ طلاق طلاق طلاق
Baqui Breakers Per Testing Video Zaroor Bunayoon Ga InshAllah
@@AGradeSolarKarachiBhai jaan Fronus kay baray me sirf suna tha lekin ab yakeen hogaya hai kay Fronus Bekaar hai 😂
@@BabarKhan-pk2ul فلحال کچرا ہے۔
Crown Xavier kesa inverter he?
@@AGradeSolarKarachi thanks bhai for replying:)
Bhaai Karachi me Solar kay lye Fabrication karwani hai mene. Any help would be highly appreciated ☺️
پرائس کیاہےتین کلوواٹ والےکی
kya yeh aik batt pe kaam krta hai ?
Nehin - ✅ It is 24 Volt Operating
Bhai 3 kilowatt system ha aur AP ne 3.7 kilowatt ka load dala ha ye operate ho ga
✅ Ayp Ke Samne Operate Ho Reha Hi is Se Bara Evidence Kya Hoga ✅ Reason? Wapda/Grid On Hai
Bhai Sirf sistam ko lagana nahi hota auske andar ane wale masle bhe biyan karo
Current price of Unit
240000
Assalam Walekum bhai mujhe ek Mahina Hua Hai nitrox per4 panel jinko 550 wale Lagaye hue lekin Aaj Tak Mera inverter 1350 what Tak Nahin Gaya bhai rahnumai farmao masale Ka Hal bataiyega
✅ Panels Kon.Se Hain ??? + Panels Ki Direction + Angle + Quality + Wiring Sub Ka Khyaal Rekhna Perta Hai - A Class Result A Grade Panels Hei Dete Hain
Arslaan bhai jinko 550 watt ka A grade panel hai aur South ki taraf hai kya masala ho sakta hai
@@ghayassghayass8582 South 180° Hona Lazmi Hai Majbori Mein 200° ya 220° South West Ki Teraf Ja Sekta Hai - Tilt Angle 22° Se 28° Ke Ander Rehna Zarori Hai
1600 say 1700 watt to generate honay chahye, why so low production?
✅ Bahi Time Check Kerian - Nov Mein 4 Panels Se 1700W Ayp Le Ker Dikha Dain Mein Aypko Master Tasleem Ker Loonga
@@AGradeSolarKarachi kis time video banai thee?
@@AGradeSolarKarachi ye limited budget system tha ya ke load k mutabik design kea tha?
Inverter price?
240
👍
Price 3 kw ip65 inverex
235-240
Amount kitni ho gi ye apnay nahi baraya. Jo bohat zaroori hai
Sir Discription Mein Juildi Hei Upload Ker Dunga
is nitrox may without battery nhi chalta kia.
❗Without Battery - Wapda is Necessary to Support Torc Load
ap ny bola k new series mai without battery chalay ga to humain kesy pata chalay ga k new series kon sa hai@@AGradeSolarKarachi
❤❤
Nitrox 3 k w 2014 wala without battery work kerta ha
Old Models No
@@AGradeSolarKarachi Sir typing mistake, 2024 ka jo new model ha nitrox 3 KW wala wo without battery work karaga, Or Starting ma 3️⃣ solar plates 575 watts per run ho jayega?
Sar hum ne bi ye setup lgwana he ap ka zafrwal me ap lga den ge or rabita number den ya hum se rapta krin tanks
Price please
✅ برادر چیک Video Description
I want to install solar system in school .
Building is open only in day time.
I think k electric load presently is about 13 kilowatt.
Need your opinion.
Loaction is karachi.
✅ What do u want ??? Cutting your Bill or You Need Backup Too ...???
@@AGradeSolarKarachi I want to make my bill zero or minimum.
What is best advice in my case?
?
@@anistanveer1298 You Can Install Both Systems Depend Cash In Hand
Koi bhai bta sakta hai mere pass nitorx 3kw inverter hai voltage protector laga hoa jaisey hai wapda sey 251v hotey hain inverter wapda cutt off kr deta hai.iss ki kya setting krien jis sey inverter wapda cutt off na krey please help.
U cannot do further settings in inverter
Inverter 3kw.prics
Bahi Check Description
Arslan bhai kindly Suggest Ziewnic Z5 Pv6000 or Inverex Yukon II 3.5kw or Veyron II 3.2KW.
JAZAKALLAH
✅ Sir Voltronics Based Inverter Legyain to Best Hoga Baqui Aypki Choice - Yukon se Veyron II Zeda Best Hai
Kabhi nitrox 6kw vs crown elego 6kw ip65 ka comparison karlo lo please
Bahi Inverter Bejhwa Dain - Comparison Ker Deta Hun
@@AGradeSolarKarachi 🤣🤣🤣 mehrbani takaluf ki zarorat nhi mai kar longa
I received better result with aerox 3.2. With parallel combination.
With wapda + Without battery this result is not possible from anyother inverter
@@AGradeSolarKarachi i will give u screen shots
@@haseebullahshah5832 03433477786
Ma shaa Allah great job.i need your phone no.i have same inverter but it is not giving good redult .
03433477786
پوری ڈیٹل بتاو نا کتنا پیسہ خرچ کیا انوریکس والوں نے کتنابنایا
یہ کس طرح کا سوال ہے ؟ انوریکس کا سوال آپ انوریکس سے جا کر پوچھیں۔ یہاں کمنٹ کرنے کا مقصد ؟
3000 watt ka he or 600 watt test karwa rahe ho bhai kyu logo ka time zaya karte ho fazol 3000 watt chala kar dekhao bagair battray k
No de den
03433477786 Whattapp
APNA no fen
صرف انوریکس کی مشہوری جو کہ تھرڈ کلاس قبضہ گروپ ھے
میرے بھائی اگر آپکا انوریکس کے ساتھ کوئی مسئلہ ہے یا کلیم کا کوئی اشیو ہے تو سروس سینٹر جائیں۔ ہم پراڈیکٹ کسٹومر کی چوائیس پر لگاتے ہیں۔ آپکا کا جو بھی جینئین مسئلہ ہے مکمل بتائیں تاکہ دوسرے کسٹومرز کو رہنمائی مل سکے۔ ایسے ادھورے اور بے تکے الزمات ہم پر کیوں لگا رہے ہیں۔
@@AGradeSolarKarachi❤
ap Ka number chahiye
Salam.sir ek video (system work mode) k ander is option time to use ki bhi banaye.aur agar apk pas mojood hai to share karain.