AOA very info video for me and all, Mein nai bhi yehi Solax 6kw ka inverter install karwayea hai pehly mein nai fronus 6kv lia tha but wo on nhi hosaka then fronus nai mujhy uski replacement mein mujhy ye inverter dia, wesy tu ye acha kam kar rha hai. ye fronus ka brand nhi hai ye solax power ka apna brand aur fronus k sath mil kar pakistan mein launch kia hai. But mery khuch concern hain 1- Jb light jati hai tu ye 5 sec k leay supply cut ho jati hai jb k fronus mein asa nhi hai 2- Ap nai kaha ye wapda sai sharing nhi leta ap check krey ye sharing leta hai show iss leay nhi hoti wo 100 watt sai kam hoti hai ap wapda k digital meter sai check kiren. 3- Mery pass bhi battery nhi hai jab sham hoti hai tu mujhy roz inverter off karna parta hai wo iss leay agr raat ko light chali jaye tu again wapda aney par ye on nhi hota ye startup condition fail honey ka error deta hai. ye iska main back draw hai. Hybrid system tu single source hota hai tu phir issey wapda aney par bhi on hona chaheay ap bhi chek kiren.........
You are right regarding Grid consumption. At 4:24 you can see on right side that voltage protector device shows 1.2-1.5 Amp consumption. At 9:02 Grid is turned off ( protector device is shut off ). Magar this consumption is false since 1-2 amp means 300watts. Power factor ka chakar lagta hai. Jab mera inverter (pv7200 fronus ) sirf battery pe ON hota hai ( no load , no grid ) to DC clamp meter se it shows 50-70 watts ( inverter ka apna idle load ). I think all inverter grid connection par 1-2 amp show karenge ( SUB settings par magar not on SBU )
Solax inverter working efficiently. Good work by your team. After installing this system does your team provide services if any problem came in system ?
Asslam o Allaikum bhai Bhai yeh kesy pta chlta hai k inverter is time grid sy sharing kr rha hai ya feed kr rha hai.. Q k start me jb ap grid feeding on ki thi to grid ki trf koi sign ni aya tha
Kya 3Kw inverter k wapda input or output pr Two Core 7/0.036 (4mm2) cable use ke ja skti hy? AKsar videos mein single core he use ho rhi hoti hy. Is ke koi khas waja??
AOA, I am in need of quotation for system which can run one 1.5 ton inverter air conditioner 2 fridges 3 fans 3lights. Please suggest kW and price without battery.
Assalamoalikum Bhai solax inverter aap na kaha say aur kasay buy kiya hay please also help me i want to buy solax same liike inverter you install in project please help me
Bahi extra watts kahan sy aa rahy hain ghar mein, Solar tu kam produce kar raha hai. Plz measure with proper devices rather than depending on the inverter display.
Assalam o Alaikum Sir jaisa ke ismay dual mppt hay toh kya series one ( 8 panels 450w) walay aik mppt par aur doosri series 450w (8 panels) ki doosray mppt mai laga saktay hain. Each series 328v ki aur 10-11 amp ki hay.
Sir g SUB mode kaisa kaam karta ha is pa? Aap janta hayn wapda fazool mayn amp use kar raha hota ha but Display par show to nai ho raha wo to nitrox pa b nai hota.
Assalam o aleikum! Bhai mujhe apne ghr me sirf 2 fans run krne hy with 4 led bulb so ap mujhe kiya recommend kre gy. mujhe asa setting banana hy jo din or raat continue asi pr run ho. Please answer kedeya ga jazakallah
Assalam o alaikum. Mey Solax 6kva ka inverter ligwaya hai 585 watts key 8 jinko bifacial panels hein, sirf aik 1 tpn ka AC hair. Panels pey AC chal Kar trip ho jata hai. Tubular battery [avk bhi hair. Problem kis chez ki setting mey hair? Please guide.
Is it illegal to do net metering on a single phase inverter??? I wanted to install same system and i am told that its illegal to feed the grid if inverter is single phase
واپڈا بند ہونے سے اس انویٹر کو پاور اوف نہیں ہونا چاہیے اگر اوف ہوتا ہے تو اسکا مطلب ہے کہ یہ کے ایلکٹرک سے پاور کنزیوم کر رہا تھا لیکن ڈیسپلے پر شو نہیں ہو رہا رہنماٸی فرماٸیں شکریہ
Asalaualikum sir heavy n full load?? Can u elaborate in watts mean single string can produce around 3480W if 6 plates r attached then on no grid n no batteries how much watts we can get from 1 string
Chal jay ga or yahi us ne test b kiya laiken aik jahtka lagta hai jis se app ki appliances kharab b ho sakti hien isliye grid ya batteries mien se 1 cheez hona lazmi hai kyun k sometimes wheather cloudy hota hai or app ko poori generation solar se nahi milti aisi sorat mien barreries help krti hien inverter ki load chalany mien or jahtka b nahi lagta appliances ko.
please tell is it possible to get net metering on single phase inverter with K electric? as far as i know, three phase inverter is required for net metering. i have three phase meter connection
@@mansoorahmedkhan6778 As *Karachi is Not Part of Pakistan* and *NEPRA policy don't apply here* that's why here u need minimum *10KW 3Phase System for Netmetering*
Mera b yehi same ha lkn 400 watt consime krne per b grid share kr leta ha. Full dhoop ha bahir 12 plates lagi hein 6kw ka setup ha. Kya issue ho skta ha?
Use CT and Temperature Sensor Properly and connect them in 485 Ports ct in ct port and tenperature sensor in bms port - Already Explained in Programing Video on this channel - Listen to it carefully
Aoa sir, is inverter main aik bohat bara issue ha k jaysay he ap is ko wapda dain gay ya sara load wapda per shift kar day ga, PV stop kar dyta ha, wapda off kar dain to thek load chalata ha, aghar is issue ka koi solution ha to please share karain, jazkallah
السلام علیکم سر یہ اپ سولیکس انویٹر کو جو چلا رہے ہیں اس میں اپ لائٹ کی شیئرنگ کر رہے ہیں اس کے ساتھ اپ لائٹ شیڈنگ نہ کریں بغیر لائٹ شیرنگ کے چلائیں جیسے کمپنی بولتی ہے کہ اس کو بغیر بیٹری ہم چلائیں گے تو یہ لائٹ شیرنگ کریں تو اس کا مقصد ہی ختم ہو گیا بغیر لائٹ شیرنگ کے چلائیں تو کیا پوزیشن اتی ہے کتنا لوڈ ہوتا ہے میرے پاس تو یہ نہیں چل رہا لائٹ شیرنگ کے بغیر 2 ایمپیر لے رہا ہے
سر مجھے یہ پوچھنا ہے کہ میں نے کراؤن کا 3.6انورٹر لگایا ہے 6 پینل 580N type لیکن2000w سے زیادہ نہیں جاتا پلیز تھوڑی gieadnes چاہئے میں نے خود انسٹال کیا ہے
Best video ever all testing covered
Make video exactly like this on ip21 inverter 3kw /5kw
Good job 🎉
Mashallah bahut Achcha kam kar rahe hain aap inverter Mein fan bhi Lage hue hain aur kuchh Din chalane ke bad update karna please
Bohat acha guide keya ❤❤❤
Well done Arsalan Bhai ❤❤❤❤
Best video conversation ever 🎉🎉🎉🎉
Nice brother ❤
AOA very info video for me and all, Mein nai bhi yehi Solax 6kw ka inverter install karwayea hai pehly mein nai fronus 6kv lia tha but wo on nhi hosaka then fronus nai mujhy uski replacement mein mujhy ye inverter dia, wesy tu ye acha kam kar rha hai. ye fronus ka brand nhi hai ye solax power ka apna brand aur fronus k sath mil kar pakistan mein launch kia hai.
But mery khuch concern hain
1- Jb light jati hai tu ye 5 sec k leay supply cut ho jati hai jb k fronus mein asa nhi hai
2- Ap nai kaha ye wapda sai sharing nhi leta ap check krey ye sharing leta hai show iss leay nhi hoti wo 100 watt sai kam hoti hai ap wapda k digital meter sai check kiren.
3- Mery pass bhi battery nhi hai jab sham hoti hai tu mujhy roz inverter off karna parta hai wo iss leay agr raat ko light chali jaye tu again wapda aney par ye on nhi hota ye startup condition fail honey ka error deta hai. ye iska main back draw hai.
Hybrid system tu single source hota hai tu phir issey wapda aney par bhi on hona chaheay ap bhi chek kiren.........
#agradesolar Arslan Bhi please feedback my observations
Bhai ap ka contact number mil jy ga kia ek information lini thi invter ke liye
Bhai backdraw nai ha, setting ka issue ha
You are right regarding Grid consumption. At 4:24 you can see on right side that voltage protector device shows 1.2-1.5 Amp consumption. At 9:02 Grid is turned off ( protector device is shut off ). Magar this consumption is false since 1-2 amp means 300watts. Power factor ka chakar lagta hai. Jab mera inverter (pv7200 fronus ) sirf battery pe ON hota hai ( no load , no grid ) to DC clamp meter se it shows 50-70 watts ( inverter ka apna idle load ). I think all inverter grid connection par 1-2 amp show karenge ( SUB settings par magar not on SBU )
Good umar khan
12v ki maximum kitny AH ki battery ko support krta hai? Led acid
Solax inverter working efficiently. Good work by your team. After installing this system does your team provide services if any problem came in system ?
yes local service available
Asslam o Allaikum bhai
Bhai yeh kesy pta chlta hai k inverter is time grid sy sharing kr rha hai ya feed kr rha hai.. Q k start me jb ap grid feeding on ki thi to grid ki trf koi sign ni aya tha
Kya 3Kw inverter k wapda input or output pr Two Core 7/0.036 (4mm2) cable use ke ja skti hy? AKsar videos mein single core he use ho rhi hoti hy. Is ke koi khas waja??
K-electric output breaker kis liye?
24 volts me acha inverter konsa he
Minimum kitne panel lagane pare ge ? Without battery without wapda work kre?
Agr net metering ni h to ct install kren gy??
Solax 4kw ip65 mai price ka idea de sakte hai ?
Es ki warranty forinus dey ra hy kiyun k kuch shops walay kah rey hain k fornius ny ye inverter introduce karwaya hy.
Kia inverex b single source py chl skta hai kia?
Mujhe lgta he display sahi info show nahi kr raha kyun k generation se ziada load bta raha he without any backup source.
Iskay aik MPPT kay sath Maximum kitnay panals lgsktay hai JazakAllah
AOA, I am in need of quotation for system which can run one 1.5 ton inverter air conditioner 2 fridges 3 fans 3lights. Please suggest kW and price without battery.
Assalamoalikum
Bhai solax inverter aap na kaha say aur kasay buy kiya hay please also help me i want to buy solax same liike inverter you install in project please help me
Solax 6k , Solis 6kw , NItrox 6kw main kitna farak hai?
Bahi extra watts kahan sy aa rahy hain ghar mein, Solar tu kam produce kar raha hai. Plz measure with proper devices rather than depending on the inverter display.
Is this single phase?
Bhai smart load kị setting bta dein
Assalam o Alaikum
Sir jaisa ke ismay dual mppt hay toh kya series one ( 8 panels 450w) walay aik mppt par aur doosri series 450w (8 panels) ki doosray mppt mai laga saktay hain. Each series 328v ki aur 10-11 amp ki hay.
Lgaa skty ha
Bro pv 1 per kio kam generation
Testing mode off kaha se hoga
How come load is more than generation? Inverter not reporting correct values
Sir g SUB mode kaisa kaam karta ha is pa?
Aap janta hayn wapda fazool mayn amp use kar raha hota ha but Display par show to nai ho raha wo to nitrox pa b nai hota.
solar utility battery
A.O.A how can contact You Sir ? Fro installation Solar System Thanks + Jazak Allah
Assalam O Alaikum Sir isme 3kW tk nai ata!?
Assalam o aleikum!
Bhai mujhe apne ghr me sirf 2 fans run krne hy with 4 led bulb so ap mujhe kiya recommend kre gy. mujhe asa setting banana hy jo din or raat continue asi pr run ho.
Please answer kedeya ga jazakallah
580 watt 2 Panels lelo sath main Mppt and UPS plus 2 batteries aram se enjoy karo
Kindly test with out solar source light in evening time ite can run load form wpada
Yes it's work with any Single source
Sir iski maximum load testing to krwa dein kisi time. Jesy nitrox 6kw to 7kw tk b load chala leta hai. Iski maximum range kitni hai
550VDC - InshAllah Load Test Kerian Ge
Bhai isper online reading same nahi aarahi Hain jab k inverter display grid sharing nahi show ker Raha online Bata Raha hai plz help
Bhai ye inverter without batteries on grid ke tarhan kam krta hai?
Kya light jane py ye band ho jata hai?
No light Jane pr direct solar pr shift hota hi
Startup_condition_fail error in same inverter
Kindly guide
Assalam o alaikum. Mey Solax 6kva ka inverter ligwaya hai 585 watts key 8 jinko bifacial panels hein, sirf aik 1 tpn ka AC hair. Panels pey AC chal Kar trip ho jata hai. Tubular battery [avk bhi hair. Problem kis chez ki setting mey hair? Please guide.
Sir apny pannels kam lageyn hain i think
Sir me bhi electric ⚡ ho or mujhe bhi ap k sat kam karna he bina charge kiya ap mujhe moqa denge
Grid feed kr k ni dikhaya
So if wapda has load shedding then the who system will shutdown and restart..???
If generation is low then wapda failure will shutdown inverter
Parallel setting please
Is it illegal to do net metering on a single phase inverter??? I wanted to install same system and i am told that its illegal to feed the grid if inverter is single phase
illegal nehin hai sirif KE Wale Darate Hain AypPehle 3 Phase Meter Issue Kerwa Lain Phir Jo Dil Chaye Kerian
Maximum kitnay panals attached hosktay hai?
max pv size 12kw and max pv input 9kw
سر کیا یہ ولٹانک بیس انویٹر ہے
واپڈا بند ہونے سے اس انویٹر کو پاور اوف نہیں ہونا چاہیے اگر اوف ہوتا ہے تو اسکا مطلب ہے کہ یہ کے ایلکٹرک سے پاور کنزیوم کر رہا تھا لیکن ڈیسپلے پر شو نہیں ہو رہا
رہنماٸی فرماٸیں شکریہ
Is this inverter work without grid and battery?? Just on pannel?
Yes - but u cannot run heavy or full loads
Asalaualikum sir heavy n full load?? Can u elaborate in watts mean single string can produce around 3480W if 6 plates r attached then on no grid n no batteries how much watts we can get from 1 string
Test this scenario, if solar is generating more watts than load then turn off wapda. Will thr system shutdown or maintain? Test it please
System will run without wapda if there is soft load running
@AGradeSolarKarachi Salam. What is the meaning of Soft Load here? Can I connect 1 inverter AC on soft Load?How many watts soft Load port can take
Some solax are gray in colour and fronus lika hota hai and some are white and siraf solax likha hai... Are they two different brands?
aoa sir. both are authentic.
@@solarmatrix224 both are same company?
Sir agr gride bhe off karain to chalay ga i mean without battery without grid
Chal jay ga or yahi us ne test b kiya laiken aik jahtka lagta hai jis se app ki appliances kharab b ho sakti hien isliye grid ya batteries mien se 1 cheez hona lazmi hai kyun k sometimes wheather cloudy hota hai or app ko poori generation solar se nahi milti aisi sorat mien barreries help krti hien inverter ki load chalany mien or jahtka b nahi lagta appliances ko.
Sir
Paralla setting kasay ho Gi plz contact no
AOA brother is mae subha ka time jab solar pv on hothi hai koi pv start error atha hai without battery
No Such Complains So Far
Kia ye sare inverter Solax, Nitrox aik he company bana rahe hai ? Sub ka shape and software bilkil same same lagta hai
next product aolax released will be much different ! keep tuned!
@@solarmatrix224who are you. I have your replies a lot. Are you official person of company?
Single source solar pe Pakistan my sb sy best knsa inverter hai as like a local made desi inverter...???
We do Not Recomended Any Inverter on Single Source - Plz Add Batteries For Compleation its Circuit
please tell is it possible to get net metering on single phase inverter with K electric? as far as i know, three phase inverter is required for net metering. i have three phase meter connection
@@mansoorahmedkhan6778 As *Karachi is Not Part of Pakistan* and *NEPRA policy don't apply here* that's why here u need minimum *10KW 3Phase System for Netmetering*
@@AGradeSolarKarachi thanks for the reply
Mera b yehi same ha lkn 400 watt consime krne per b grid share kr leta ha. Full dhoop ha bahir 12 plates lagi hein 6kw ka setup ha. Kya issue ho skta ha?
May be software version or CT direction or battery sensor issue
Bro single sting hai ya phir double sting
Is this a 3 phase inverter?
Single phase
Bro kia hum ye inverter without battery chala skty hein long term me. Mean kch months without battery chala lein then batteries connect kr lein?
Yes U Can Run it Without Battery
@@AGradeSolarKarachi Jazzak'Allah Khair bhai ❤️
Assalam
What is the model of this inverter?
solax x1 hybrid lv 6kw
Load shedding mai ye system work krega without battery?
G bilkul kar sakta hi
Chalta hai
Bhai ap kia recommend krenge kia yeh inverter lena chaiye kia yeh inverter worth buying hay ?
✅In Low Budget it's Best ⚠️ *BUT* - If u don't have budget issue then go for other ip65 brands
@@AGradeSolarKarachi iska service centre hyn karachi ma ?
@@AGradeSolarKarachi jahan warranty claim hoskae ?
@@beastsharukh6095 SOLAX Lahore
@@beastsharukh6095 Karachi Proper Claim Warranty NITROX
CT installation ke video be uploaded karen
just mind arrow to the grid
I'm installing this inverter. Net metering nahi hai. CT ka arrow grid ki side pe hoga ya inverter ki side pe without net metering. Pl koi bta dein
CT arrow toward grid
The Startup Condition Fail error what does it's mean plz respond
Use CT and Temperature Sensor Properly and connect them in 485 Ports ct in ct port and tenperature sensor in bms port - Already Explained in Programing Video on this channel - Listen to it carefully
Aoa sir, is inverter main aik bohat bara issue ha k jaysay he ap is ko wapda dain gay ya sara load wapda per shift kar day ga, PV stop kar dyta ha, wapda off kar dain to thek load chalata ha, aghar is issue ka koi solution ha to please share karain, jazkallah
F
Solar only Karen
F
Kia solax inverter 8kw main bhi military hay
In UpComing Days 8, 10, 12 KW Single Phases are Coming in Market
Janab ya wifi ki reading matching nahi ker Raha hai waja?
Same
@@aqeelmansha3275 battery load sitting minimum range or maximum rang Kahan set Hogi sitting option?
Apna ghar malaga na ha
Will it work with two batteries
yes max 16 batteries
Is mai to fan laga hua hai ye kons ip65 hai
fan is for heating sink
Grid kay jatay hi yeh aik dafa load ko cutt off karkay phir say uthata hai. Without battery iska koi solution ya setting hai to please bata dain.
Only Solution ✅ Add Battery
@@AGradeSolarKarachiwhat is MINIMUM Price of battery that I can add to it?
@@qaiserkhokhar8400 With Solax Inverter Only Solax Battery Will Sinc - Price 370
Koi Bhai hai jisny solax 6kw lagaya ho plz reply me some questions
Solar ki generation km jb k load kuch ziyada hi hai video main aisa q hai....
Grid bhi share ni ho rha btry bhi ni hai
Synchroniz hony m kuch second ka difference araha hoga
@@umairghaazi yani k without btry aur without wapda kaam kr jata hai
startup condition fail error ata ye kyn hy?????????????
Assalam o Alaikum
Is fault Ka solution Mila aapko?
Sir please iss ki setting bata dain hum se iss ki setting nahi ho rahe
Yar ek baat bta sakty hen? Agr ap use kr rhy hen iska Fan/Noise Kitna HOTA Load per ? Ziyada he normal he ya bilkul Kam he?
@@FortniteMaps load par iss ka fan/ noise itna zayda nai hai .normal hai
Sir
Plz mujay bahi parallel setting karni ha
Plz contact no
Koi acha dealer bata den Karachi ma jiske pass inverter mil jaye
Direct Fronus Office se utha len
السلام علیکم سر یہ اپ سولیکس انویٹر کو جو چلا رہے ہیں اس میں اپ لائٹ کی شیئرنگ کر رہے ہیں اس کے ساتھ اپ لائٹ شیڈنگ نہ کریں بغیر لائٹ شیرنگ کے چلائیں جیسے کمپنی بولتی ہے کہ اس کو بغیر بیٹری ہم چلائیں گے تو یہ لائٹ شیرنگ کریں تو اس کا مقصد ہی ختم ہو گیا بغیر لائٹ شیرنگ کے چلائیں تو کیا پوزیشن اتی ہے کتنا لوڈ ہوتا ہے میرے پاس تو یہ نہیں چل رہا لائٹ شیرنگ کے بغیر 2 ایمپیر لے رہا ہے
Price inverter ki?
270
Keep testing this inverter... Nitrox is very expensive
4 kw available hy
Price kiya ha!! koi link ha testing!?
@@malick991 280k
Nitrox ka boycott karden rocket ki tarah price neechy ayengi
بھائی سارے دھوکے لگایا جاتا ہے بغیر بیٹری اور بغیر واپڈا سے سسٹم چلتا نہیں اگر تھوڑا سا اندھی اتا ہے تو سارا سسٹم بند ہو جائے
Bhai mujha
Nitrox ka bycott keryn please
Inverter price
275000
Total system price????
@@farasatali2646 No Only Inverter
please confirm, when Batteries connect with it , it will take power from grid all the time , in night ! even load is zero from house !
It depend upon u how u set it's programing
Solax prlall sating
Bahi jann ma na BHI prallar setting kani ha information chay
Plz contact no
Sir contact no
AS Salamu Alikum Bhai , 3 say 4 kw main koi Acha inverter tu batayeeen ,
4KW Mein Power Le Lain
@@AGradeSolarKarachi Bahi kon sa inverter likha App ney Max power or evpower ?
سر مجھے یہ پوچھنا ہے کہ میں نے کراؤن کا 3.6انورٹر لگایا ہے 6 پینل 580N type لیکن2000w سے زیادہ نہیں جاتا پلیز تھوڑی gieadnes چاہئے میں نے خود انسٹال کیا ہے
Panels konse hyn ?
Jinko N type @@beastsharukh6095