How to set Purifier to Clarifier

Поделиться
HTML-код
  • Опубликовано: 9 авг 2021
  • This is the procedure of how to set the purifier to clarifier in Mitsubishi Selfjector SJ*GH series with HIDENS system without removing or changing gravity disc and without installing blind disc at the bottom of disc stack.

Комментарии • 7

  • @marineengineer1403
    @marineengineer1403 2 года назад

    Very detailed loved it...Please also make a vedio on how to change the discharge time of purifier.

  • @aligoharmughal4952
    @aligoharmughal4952 3 года назад +1

    Thank you for making this video Dear Sir, GOD Bless.

  • @rajivranjan9902
    @rajivranjan9902 Год назад

    very detailed information,, although i didn't try onboard thanks 👍

  • @spoicynot7587
    @spoicynot7587 Год назад

    Thanks for the video sir. I have a problem with my MELO purifier which is working as clarifier, every discharge it has a leaking alarm, what might be the problem of this one sir? Thank you!

  • @sataram3859
    @sataram3859 2 года назад

    Can you please tell on my ship we have Sj 100gh purifier which is working as purifier ,its recirculation line pressure is high 2.8 bar ,and purifier (small amount of oil) leaking during operation . Can u suggest what is problem

    • @joseheraldflorese9159
      @joseheraldflorese9159  2 года назад +1

      If it is working as purifier, the circulating valve must close and heavy outlet valve is open. And if you have leak in heavy outlet, you might have problem with your interface like incorrect gravity disc.