EG4 18KPV Testing Discharge when Limiting Amps - Awesome Features on the 18KPV!

Поделиться
HTML-код
  • Опубликовано: 6 сен 2024
  • $50 off orders over $500 with code : RODNEYHUNT50
    Upgrade Program info HERE! signaturesolar...
    EG4 18KPVHybrid Inverter: signaturesolar...
    EG4 Powerpro battery: signaturesolar...
    EG4 Conduit Box: signaturesolar...
    3 inch Core Drill Bit: amzn.to/4bWilaq
    100 Amp Disconnect amzn.to/3TJ9H6M
    IMO PV Disconnect signaturesolar...
    MY CURRENT SYSTEM EQUIPMENT USED:
    (3) EG4 6000XP INVERTERS signaturesolar...
    (17) EG4 Batteries signaturesolar...
    (12) 305 WATT HYUNDAI SOLAR PANELS signaturesolar...
    (28) SOLARVER 455 WATT PANELS signaturesolar...
    (2) VICTRON LYNX POWER IN BUSBARS amzn.to/48ub3bz
    (1) VICTRON LYNC DISTRIBUTOR signaturesolar...
    (2) 4/0 BATTERY RACK CABLE SETS signaturesolar...
    (8) 2 AWG BATTERY AND INVERTER CABLE SETS signaturesolar...
    (1) 500FT PV WIRE FOR DIY signaturesolar...
    (1) CHARGEVERTER 100 AMP BATTERY CHARGER signaturesolar...
    (12) MC4 CONNECTORS signaturesolar...
    ALL LINKS ARE AFFILIATES WHICH HELPS THIS CHANNEL WITH A SMALL COMMISION FROM EACH SALE

Комментарии • 47

  • @zwei176
    @zwei176 4 месяца назад +2

    EG4 rates that battery for 200A continuous discharge. 160A is really safe and recommended, but I am going to set mine to 185/190A until I hook up a second in parallel.
    Great video!

    • @rodneyhunt
      @rodneyhunt  4 месяца назад +2

      Hey thanks! Just taking it easy until I get more solar hooked up. Then will increase output since solar will do most of the work until later in the day

  • @brandonburke4437
    @brandonburke4437 4 месяца назад +2

    Thank you for posting your videos about the EG4 18kpv install at your parent's house. Very similar to my install. I have searched for months about this situation and you have helped me more in an hour watching your videos than months of searching. Keep up the good work!

    • @rodneyhunt
      @rodneyhunt  4 месяца назад

      Hey thanks! More to come but slow progress on the bulk of solar panels getting installed. That is my goal to help people looking to use this equipment

  • @stevenfrazier8939
    @stevenfrazier8939 5 месяцев назад +2

    It is great to see how the 18K can be used. We use our 18KPV completely off grid with only 30 kilowatts of batteries. I think everyone should get at least one.

    • @rodneyhunt
      @rodneyhunt  5 месяцев назад

      Features are awesome from the testing so far. 👍

  • @fullyelectric
    @fullyelectric 3 месяца назад +2

    @Rodney so i am doing a ton of research and so far the EG4 18Kpv or the LuxPowertek LB-US 8-10k will do 100% what i am looking for, however the 18Kpv can support way more than the max 6Kpv I have, and future EG4 12Kpv or LuxPowertek LB-US 8-10K can do 2x my max, so buying the EG4 18Kpv that supports 3x more than my MAX pv I feel is way over kill and costing 3-4x more than the 6000XP is truly a waste, all that extra money could go to more batteries, and the ONLY feature i truly like on the 18Kpv is the fact you can use the GRID connection to backfeed your main panel, what i do not understand is both the 6000XP and the 18Kpv has two CT’s RJ45 ports, so why can’t the 6000XP do the same via its GRID connection? Would be awesome if this could be tested.

    • @rodneyhunt
      @rodneyhunt  3 месяца назад +1

      Probably so people will purchase the grid tie inverter is my only guess. The 6000xp is marketed as a off grid inverter so giving it those functions at that cost point might nit be wise from a business perspective is my guess.

  • @hendersonsobers396
    @hendersonsobers396 5 месяцев назад +3

    Thanks for this video Rodney. Always enjoy your content.

  • @cgutowski471
    @cgutowski471 5 месяцев назад +2

    Great video! I like the way you can ‘try’ to zero out the main panel with this inverter. Guess you have to really figure out what you want your discharge SOC to go down to in order to make sure you have enough battery for critical loads when grid (and main panel) is down.

    • @rodneyhunt
      @rodneyhunt  5 месяцев назад +2

      Very true! Once all panels are installed I will start moving some loads over to see how it does. I’m sure more batteries will be coming in the future but you got to start somewhere

    • @cgutowski471
      @cgutowski471 5 месяцев назад +1

      @@rodneyhunt keep up the great content. Can’t wait to see more on this one. I installed a 6000xp but wish I went this direction instead to supplement power back to main panel with excess PV after critical loads are met and batteries charged.

  • @Alex-Suzanne
    @Alex-Suzanne 5 месяцев назад +3

    Great video. Thanks for showing some of
    the features.

  • @roslynandbobchauvin2378
    @roslynandbobchauvin2378 10 дней назад +1

    Thanks for this video!

  • @doinkeroni
    @doinkeroni 4 месяца назад +1

    Thanks for sharing! I am trying to understand the maximum power it can supply in a grid-tied configuration. For example, if the load is more than the ~15kw inverter capacity, will it just keep supplying 15kw from the inverter and supply the rest of the load using the grid (up to the 200amp grid pass through limit?)

  • @matthewknight5641
    @matthewknight5641 5 месяцев назад +4

    That 18 is kinda a bad a** inverter. Some people seem to like it better than the 15k solarks from what I see on RUclips

    • @rodneyhunt
      @rodneyhunt  5 месяцев назад +1

      Seems to be from the testing I have done so far. 👍

    • @matthewknight5641
      @matthewknight5641 5 месяцев назад

      @@rodneyhunt 5 grand seems like a lot of money to me but with its capabilities and size I guess it's a great price. Ive never seen a inverter that had all the features like you was showing us. Thanks for doing the videos

  • @ScottieBMan
    @ScottieBMan 5 месяцев назад +1

    Thanks for sharing, also you are looking trimmed up! Good work!

    • @rodneyhunt
      @rodneyhunt  5 месяцев назад +1

      Hey thanks! Carnivore diet

  • @amritgrewal7388
    @amritgrewal7388 Месяц назад +1

    Question regarding pass-through mode with grid assist: When the house load exceeds the max 50A 12kw AC output of the inverter (supply from battery/solar/grid), does the inverter passthrough all this power from the grid completely? Or does the inverter passthrough only the incremental power from grid, while using available solar/battery concurently? Example: If house load goes from 10kw to 18kw, will it switch to passthrough all of the 18kw from grid with no solar feeding the load? or just the additional 6kw from grid (18kw load - 12kw max ac output) allowing solar/battery to concurrently feed 12kw to load? Thank you

    • @rodneyhunt
      @rodneyhunt  Месяц назад

      I have this as a partial home backfeed breaker setup. But on the grid side of inverter it will feed back into main grid panel to cover loads when PV or battery power are available. Minus any loads you are powering on your critical loads panel. So grid and inverter will power main panel loads at the same time in this setup. I will need to check on the grid bypass for whole home setup

    • @rodneyhunt
      @rodneyhunt  Месяц назад

      So I verified that yes after 12kw all loads will be on grid bypass until the loads are less than 12kw again. When using whole house setup

  • @andys5203
    @andys5203 Месяц назад +1

    Awsome video, Rodney. I am purchasing all the components as the budget allows. I am planning to buy the Eg 4 12k and the solar panels. Will this work without the critical load panel and battery ?The objective is not to sell back to the grid. At least I can save on my utilities bills. Thanks

    • @rodneyhunt
      @rodneyhunt  Месяц назад

      Yes if you basically install grid input directly to inverter then you panel from your load. It is in the manual. Basically you will have grid bypass that way. So you won’t use the 70 amp backfeed breaker like I did with the critical load panel. You need a line side tap or disconnect. You will see it in the manual.

    • @rodneyhunt
      @rodneyhunt  Месяц назад

      If you do it my way if you lose grid power your main panel will have no power.

  • @martinsteflik1329
    @martinsteflik1329 5 месяцев назад +1

    Can test to see if it will run without a battery? Just solar and grid.

  • @MLCATSkizzers
    @MLCATSkizzers 4 месяца назад +1

    is there any chance you could post your settings for the 18k? i have a nearly identical setup that i just installed but i cant get the settings set right

    • @rodneyhunt
      @rodneyhunt  4 месяца назад

      Will see what I can do

  • @tobymaples7646
    @tobymaples7646 4 месяца назад +1

    Hey Rodney, I just stumbled upon your channel the other day and have been going through all your videos. Do you know if the 6000xp has a built-in way to set up zero export if I fed it into my main panel at home? trying to figure out if I want to go off grid or hybrid. they wont do any sort of net metering here from what I was told. i don't want to give them free lunch after they have been taking advantage of a monopoly all these years. Thanks

    • @rodneyhunt
      @rodneyhunt  4 месяца назад +1

      No it doesn’t. But the 18k has that built in and have been testing that out on my parents house. Hopefully get the bulk of the panels installed soon to make a real difference!

    • @tobymaples7646
      @tobymaples7646 4 месяца назад +1

      @@rodneyhunt Thanks for the quick reply

    • @rodneyhunt
      @rodneyhunt  4 месяца назад

      👍

  • @newbie101
    @newbie101 5 месяцев назад +1

    Nice video and nice pergola. May I know which brand of pergola are you using? How easy is it to put it together. Maybe an affiliate link would be helpful. Thanks.

    • @rodneyhunt
      @rodneyhunt  5 месяцев назад +1

      Wouldn’t recommend the pergola as this will be temporary. Going to build a lean to type shelter for the panels soon. But it was from Lowes I believe

  • @ToddDesiato
    @ToddDesiato 3 месяца назад +1

    How loud is it while it's running? Do the fans whine all day and night?

    • @rodneyhunt
      @rodneyhunt  3 месяца назад +1

      Completely silent during low power usage and no PV input. If higher than maybe 5000 watts output it starts to make noise. Will do a test video in the future showing exactly how much

    • @ToddDesiato
      @ToddDesiato 3 месяца назад +1

      @@rodneyhunt I just installed a Hoymiles 7.6kw Hybrid. It has no fans, so it's as quiet as a church in my garage.

    • @rodneyhunt
      @rodneyhunt  3 месяца назад +1

      Nice! I was looking at some of the micro inverters they have for testing

  • @jimbob100-d3l
    @jimbob100-d3l 5 месяцев назад +1

    The max output current for the 18kpv is 50 amps though right?

    • @rodneyhunt
      @rodneyhunt  5 месяцев назад +1

      No since it can surge much higher or if it is using 120 volt loads the amps will go up as well. But the amps I talked about most of the time are DC amps except when speaking of the AC grid backfeed breaker of 70 amps.

    • @jimbob100-d3l
      @jimbob100-d3l 5 месяцев назад

      @@rodneyhunt Oh nice, thanks!