A day in the life of a gas engineer

Поделиться
HTML-код
  • Опубликовано: 4 ноя 2024

Комментарии • 50

  • @CarlAtkinson-zu1zh
    @CarlAtkinson-zu1zh 11 месяцев назад +3

    Good to see you making videos again, always watched all your previous videos

    • @snapgas9832
      @snapgas9832  11 месяцев назад

      Thanks a lot! Will continue

  • @charliefox6987
    @charliefox6987 11 месяцев назад +1

    Thanks for making vids again mate always good for learning

  • @gibbodive140
    @gibbodive140 11 месяцев назад +3

    After a simple check of the system circulation, Check for a partially blocked hex !
    The water can operate, normally with a probable mod down, but the heating circulation can be badly affected.
    Can normally clean them with an aggressive cleaner - powerflush machine direct on the 22mm feeds
    More problematic on the 37KW boiler - system and combi.
    Also dont operate the boiler on max or chimney with circulation issues and keep temps down !
    The boiler you were working on looked like it was the earlier hex with the overheat fuse at the top. Activate that and you are in trouble !
    New Hex - £500 +
    A lot of money spent on that boiler - is it worth it ?

    • @Purebeltersteve
      @Purebeltersteve 11 месяцев назад

      The way the waterways are on this hex its really hard to be blocked. Its something with the system 100 percent

    • @Purebeltersteve
      @Purebeltersteve 11 месяцев назад +1

      Or diverter stuck in hw

  • @ryantidball1118
    @ryantidball1118 2 месяца назад +1

    Pretty sure the pump is fine the new high efficiency pumps don’t have pump speed they modulate down with boiler

  • @antoniogalluccio4213
    @antoniogalluccio4213 11 месяцев назад

    My circulTion issue wast at the diverter not going fully to ch position. Pin stack half way through like mid position. We only reckon a week aft
    Er when it fully blocked in hw position and no more ch. At the beginning we were suspecting blockages, air locks, broken valves and so on. It was a remeha avanta plus. New cartrige and motor, happy days

  • @dominichalliday8929
    @dominichalliday8929 11 месяцев назад +1

    Had a similar thing with a baxi recently, turned out to be the return valve broken inside. It felt fine but the ball inside wasn't opening properly

    • @snapgas9832
      @snapgas9832  11 месяцев назад

      Great shout there mate!! Will look into yhis

  • @Limitlessboilers
    @Limitlessboilers 11 месяцев назад +4

    I would say put water through the flow and see if it comes out the return pipe. Proves no blockage. My suspicion it could be the divert valve, if the cartridge in not in the body in the correct orientation you will get the issue you are having. Good luck 👍

    • @snapgas9832
      @snapgas9832  11 месяцев назад

      Cheers mate, great suggestions, with the diverter cartridge it would also run down the flow on hot water I think, anyway I will update

    • @matthewtrueblood408
      @matthewtrueblood408 11 месяцев назад

      Agree. I’d be disconnecting the flow and return at the boiler and with a hose connected to an outside tap send water round the system to see what comes out of the 2nd hose connected to the return. Also I’d be changing the right hand side panel too after all the insulation & sound deadening has fallen off. Love an Ecotec but I’m afraid so many are neglected on social housing or insurance(BG, Homeserve) contracts with minimum preventative maintenance carried on annual “service”.

    • @Limitlessboilers
      @Limitlessboilers 11 месяцев назад

      @@matthewtrueblood408 inspection service done in less than 10 minutes. Replace the boiler every 8 - 10 year's due to lack of servicing. Big companies make more money in the long run

    • @CarlAtkinson-zu1zh
      @CarlAtkinson-zu1zh 11 месяцев назад

      It would be interesting to see if a brand new diverter valve would solve the problem, even just replacing the diverter motor?

    • @Limitlessboilers
      @Limitlessboilers 11 месяцев назад +1

      @@CarlAtkinson-zu1zh I would replace the whole diverter personally. The guy that done the flush must of had flow through the system

  • @alan_edwards_404
    @alan_edwards_404 11 месяцев назад +1

    I hate jobs like that, i had it too and on a valiant, in the end changed divertor and it sorted the problem!

    • @snapgas9832
      @snapgas9832  11 месяцев назад +1

      Yeah very annoying, I will wait and see what comes from it over the coming days, I’ve tried my best
      Thanks for watching

  • @dominicmathieson9114
    @dominicmathieson9114 11 месяцев назад +1

    It’s not an old one pipe system by any chance which is linked through each rad with a stuck trv? Just a possible suggestion as would shut off circulation to system

    • @snapgas9832
      @snapgas9832  11 месяцев назад +1

      Great suggestion mate! I will be re attending at some point no doubt, thank you for that

  • @sergiofernandez3725
    @sergiofernandez3725 11 месяцев назад +2

    Interesting fault. Might be worth using a thermal camera and walk around the property following the pipework. Would be great to have a follow up video on this

  • @williamstables6117
    @williamstables6117 11 месяцев назад +1

    The right hand panel insulation looks comprimised, does that not affect the integrity?

    • @snapgas9832
      @snapgas9832  11 месяцев назад

      That’s insulation as you say mate, the case seal is the front insulation panel and the 2 clips either side of the pcb panel

    • @williamstables6117
      @williamstables6117 11 месяцев назад

      @@snapgas9832
      so it's not like a Glowworm, when the side panel insulation is worn, they advise you change as integrity is compromised?
      I'll ask the question with Vailant

    • @williamstables6117
      @williamstables6117 11 месяцев назад +1

      it's always good to know.
      Spoke to Vaillant, Tech. They advise that that the panels should be replaced as the integrity is at risk.

    • @jackclowry9644
      @jackclowry9644 11 месяцев назад

      Insulation to side panels on ecotecs is for sound deadening nothing more. I have seen a batch of 824s with no insulation. My old supervisor worked for vaillant for 35 years. S53 generally is down to main heat exchanger being blocked. However when fitting an erp pump into the older models there is a restrictor kit available to fit inside the flow into the heat exchanger. As without kit faults and blocking status codes will occur. I believe f75 and also s53 possible. I haven't worked on vaillants for a while now so there could be technical updates with regards to erp pump. Best of luck. Heat ex certainly sounds blocked to me all that clicking

  • @MagicDoughnut
    @MagicDoughnut 11 месяцев назад +1

    What's name of the inflator your use to recharge the EV?

    • @snapgas9832
      @snapgas9832  11 месяцев назад

      Makita dmp180z I think

  • @RoobieRoo2
    @RoobieRoo2 11 месяцев назад +2

    lolz service and repair engineers don't do solder or pressfit, they are a different breed man! :P

    • @snapgas9832
      @snapgas9832  11 месяцев назад +1

      Haha leave off 🤣 got to love a compression fitting 😂

    • @RoobieRoo2
      @RoobieRoo2 11 месяцев назад

      lolz, just messin bro, love the vids, honestly great stuff, canoe filter is there to protect the plate to plate, massive pain in the a$$ to have primary blocked@@snapgas9832

  • @gazzagasco
    @gazzagasco 11 месяцев назад +1

    Any air pips in the loft.

    • @snapgas9832
      @snapgas9832  11 месяцев назад +1

      No mate it’s a ground floor flat, and is all in boxing in

    • @gazzagasco
      @gazzagasco 11 месяцев назад +2

      @@snapgas9832 I’d have drained it at the rads and filled it with the pump aav open sounds like air at highest point. Pain in the arse pal

    • @snapgas9832
      @snapgas9832  11 месяцев назад

      Proper😂

  • @orfeyo130
    @orfeyo130 11 месяцев назад +1

    Diverted cartridge wrong way round 👍

    • @snapgas9832
      @snapgas9832  11 месяцев назад

      But would be going down the flow on hw if that wasn’t right (just from experience I’ve had it before after I changed a cartridge
      I will check thi

    • @orfeyo130
      @orfeyo130 11 месяцев назад

      Had pretty much same as you, was convinced the main heat exchanger was blocked but just checked the diverter cartridge as a shot in the dark an it was wrong way round! Worked like a dream after🤞 best of luck👍

  • @zali1457
    @zali1457 11 месяцев назад +1

    Old diverter valve or non return valve probably broke off when the power flushed

    • @snapgas9832
      @snapgas9832  11 месяцев назад

      Exactly my thoughts there mate, has a programmer in another room so probably converted to combi at some point but all hidden in boxing and below ground
      Thanks for watching