Why 110 V DC Supply used in substation for control Circuit
HTML-код
- Опубликовано: 23 дек 2021
- Why 110 V DC Supply used in substation for control Circuit
Why DC Supply used in substation for control Circuit 110Volt
1.Why 110v DC for control circuit? Why not AC?
2.Why Power Backup Required for substation control circuit
3.What If we Used AC Supply Instated of DC What will Happened
4.How to maintain 110V Dc Battery Charger Healthiness
5.Difference between Control circuit and power circuit
6.110Volt DC Supply usage in electrical substation
7.Which source is reliable for substation control circuit
8.Why DC Supply Preferred for electronics circuit
9.How to maintain the 110 volt DC charger and Battery
10. Maintenance check list for 110V Dc charger and Battery
Transformer Parts and function animation
• Transformer Parts anim...
Breaker parts and function
• Breakers
About our channel:
Here you can find a videos for industrial equipment basic working principle & efficient Operation maintenance in Tamizh(Tamil) with simple animation.
Electrical & Instrumentation
Transformers parts and working animations
HT/LT breakers MCB,MPCB,MCCB,ACB,VCB,starters explanation
Induction motor and alternator working animation and DG maintenance
Types of sensors and working principle with usages -RTD, Thermocouple, Proximity sensors,
Earting system and its types-TT, TN-C TN-C-S
CT- Current transformer working and connection
Electrical Distribution system,Switch yard operations,motor,VFD, DG...etc
Utility
Boiler,power plant,Chiller plant,Compressor,Fire protection systems,Water treatment plant-WTP/ETP/STP, AHU-Air handling unit,BMS-Building management system,HVAC-Heat and ventilation air conditioner.
BEE-Bureau of energy efficiency
Energy manager exam notes and previous year question paper with answer.
This channel will help for engineering students, freshers and industrial working people.
Electrical Home appliances
Fan connection and troubleshooting
UPS and inverter connection
House wiring and troubleshooting explained with simple animation
Refrigerator working animation and troubleshooting-Thermostat issues and over cooling issues explained
Electricity bill reduction ideas and basic understanding of Tamil Nadu tariff rates
AC-Air conditioner working animation and service troubleshooting
Mixer,Grinder troubleshooting and maintenance
#110VoltDC#BatteryCharger#110V# - Наука
Electrical is very interested by your explanation.... congrats bro...
Thank You Sir. Really Encouraging. Keep Doing sir💥🙏🏻
Very clear explanation bro👍
The one only best visual explain video bro..semma
Your explain is very good
Good Explanation.............Congratus
Super explained
Good explanation
Super bro thanks
Nice 👍
Useful
Superb....Keep it .....💚👷
Super bro
Bro generating station la irunthu ethuku 11kv mattum generate panranga idha pathii sollunga bro
Sir super explain
Nenga vera level
Transformers, Vcb, ACB, lt panel, generator, compressor maintenance check list upload pannuga
Bro marshalling box installing apram settings video podunga bro
Super
Nice
Close tirp coil epde manifest pannarathu bro
Bro lotto pathi video podunga
Osm
Please can you make it in English?
Thanks.
One video please
DC output supply cut panna what happend
Bro your explanation ok bro but MV panel inside 110v enga connect panranga ,110 varla na epadi troubleshoot panrathu solunga
Used for trip circuit only.
sir, How to reduce specific gravity of battery 1260 to 1200 and how to increase 1180 to 1200
Periodically maintain distilled water in battery .When ever water required top up and do not top up above prescribed level ..By this maintaining proper maintenance of battery you can achieve Good SG values
110v charger, battery fault agitu, battery change panra apo VCB trip aguma.
Breaker Trip aagathu sukumar,indication. And protection relay Ella off aairum,
But off pantrathuku munnadi vera interlock wiring iruka nu check pannikanum
Mr.sukumar , in nowadays all Switch Gears have mechanical interlock or Latch .When ever DC fails Switch Gear in ideal position (existing position ).But due to absence of control voltage , we cannot operate from LCS or DCS OFF or ON and We relay/protection will not operate ...If some case DC fails and Equipment runs abnormally the automatic tripping protection will not work ...That's Why we more concern about control supply with backup
Why 110V DC and Why not 48V DC or other Voltage rating in DC
Very dangerous.
Not sure where you at but we use 110 V AC, much safer.
220 DC in. Substation
English pleaseeeee!!!!!
These people then speak in English also like this. Please bring clarity in communication instead of running 100 miles an hour.
LOTO and Equipment history card tobe updated
Super sir
Super bro thanks