Good work.primary current calculation is perfect.there are many videos where they calculate primary current as half of the calculated value of primary current.it is wrong. Calculation done in this video is correct.thanks
Nehin koi bhi random se select nehin hota. Jab karogi tab aap ka wire window ki space me nehin bhar paoge.isliye wire ki swg aur turns ki hisab se core ki central limb width select hi hota hai. Aur jab 24v me 40A primary ka power hoga:24×40×0.8=24×32=768 watt hi hoga kyunki hamne ac me p. f 0.8 hi hota hai. Aur 250v ke liye 5A aur 200 v ke liye 6.25A to 150 v ke liye 8.4A hi hoga
Sir transformer ka watt aur stack height ka kya relation hai.E type core ka center ka patti ka jitna charai utna stack height rakhni chahiye ya watt ke anusar stack height ko kam ya jyada rakhna hota hai.yedi iska koi formula hai.to ispar vdo bana dijiye
12 0 12 ko kuch esa keh shakte 0 12 24 Center tap ko agar common point manege to hame done sire me 12 volt milaga aur ek sire se dusare sire me jode to total voltage 24 milega 12+12 24 Aur ek positive half cycle me 12 volts hai To 40 ampere ek 12 volt me Aur negative half cycle me 12 volts 40 ampere To total ho gaye 80 Ampere
@@ELECTROGYAN Yeh 45/CA(cm²) 7.5/CA(inch²) rule ka error rate kitna hai? Kitna reliable hai yeh formula? Mujhe ek 1000 watt k 24 volt wala transformer banana hai inverter k liye. Isliye jawab jitni jldi diye jaye utna behtar hai.
sir aapse request hai Ki mai 12 volt 3 amp ka transformer design karna chahta hu.iska calculation Kaise karenge.ispar ek vid isi tarike banaiye aur samjhaiye. is transformer mei input 220 volt primary aur output mei 12 volt 3 amp hoga.
To fix formula 7 or 8 ya 7.5 kaise nikala jata hai ye fix kyu hai ... Please describe ...Ye confuse karta hai kyuki toroidal TF me 44 ka formula lagta hai....Please ise jarur bataiye....
1000 watt= 1000/0.8= 1250-VA . Aur har transformer me kuchh na kuchh loss hi hota hai isliye ek achha quality ki transformer ki efficiency 80℅=0.8 hi hota hai to transfofmer ki power =1250/0.8=1565-VA hi hota hai. To 24v primary ke liye hamko 1565/24=65-A hota hai jis ke liye 4 no swg copper wire se winding karna hoga aur 250v secondary ke liye 1565/250=6.26A hi hota hai jiske liye 14 swg ka copper wire se winding karna hoga.
Nice video. I've a question on transformer. What specifications should I need to make a step-down transformer 230v ac to 130v ac of 1.5 kw/ampere? e.g. * core and bobbin size, * wire gauge and turns for both primary and secondary windings. * Any others things which I forgot to mention here.
I thought that the transformer formula was in metric, such as core square CM. Also gauge of wire formula is as 700circ mils times current times duty cycle. If power not on all times during time period , then the gauge wire can be smaller. circ mils times % duty cycle. Also, if choosing a LARGER core than required, then there is less turns that have to be wound on bobbin because of formula. Assembling a low frequency transformer with E and I laminations can be interleaved, or separated , so as the top I set comes off, so as bobbin quickly removed for rewinding. The separate laminations type requires strap over unit to hold together. The old style radio chokes were like that method.
Please share me the database of swg core and turn per voltage please share me the database so I can used for making or share me the links I can download it please share me
For Customized Transformers Orders
Call on - 7975157316
Yogesh Kumar
Galaxy Transformers, Delhi
Excellent explain sir 🙏🙏
Bahut hi khooob bro
Thank sir
Very informative , now in this you explained the bobin size calculation , great
I also created the playlist
Watch it
It will clear all of your doubts regarding transformer 😊
Nice and informative..
Best video, I have never seen such a beautiful & clear explanation. Keep up the good work. You are gifted one when it comes to explanation.
Thank you 😊
Super vdo thanks
Buhat achi videos hsin bhai
Thank you so much sir for give good knowledge 🙏
Subscribe for more☺
@@ELECTROGYAN ok sir 😊
Very good sir.good your all videos.
Good video brother
good video
Good work.primary current calculation is perfect.there are many videos where they calculate primary current as half of the calculated value of primary current.it is wrong. Calculation done in this video is correct.thanks
Make sure to subscribe 🔔 for more
Thank you 😊
Jo bobin size size apne select ki 1.5 o random koi bhi chose kar sakte hai kay uski jagha 2 inch bhi select kar sakte hai kay
Ha
Nehin koi bhi random se select nehin hota. Jab karogi tab aap ka wire window ki space me nehin bhar paoge.isliye wire ki swg aur turns ki hisab se core ki central limb width select hi hota hai. Aur jab 24v me 40A primary ka power hoga:24×40×0.8=24×32=768 watt hi hoga kyunki hamne ac me p. f 0.8 hi hota hai. Aur 250v ke liye 5A aur 200 v ke liye 6.25A to 150 v ke liye 8.4A hi hoga
Har transformer ki power aur minimum voltage se iska window aur CSA ki product hi niklta hai. Ye engg hai koi khel nehin. Pehle thik se samnho engg ko
Sir aap welding transformer ke baare mei isi tarike formula ke saath samjhaiye vdo banakar.
Jaroor
Apki requirement kya hai waise
Kitne ampere ka transformer aap chahte ho
Hello dear sir!
200 amp 60 volt for welding transformer
sir i type core ki complete calculations b kindly formula wise samja dijye ga plus aluminum wire selection
sir 100 amp.
Sir aap welding transformer ke bare mei isi tarike se formula ke saath samjhaiye aur vdo bana dijiye.
Great explain sir please make one video for sine wave inverter split winding transformer.... Waiting for your video... Good👍👍👍
Sir aap stablizer ke transformer winding ka bhi vdo isi tarah se bana dijiye.
👍👍👍👍👍
Sir transformer ka watt aur stack height ka kya relation hai.E type core ka center ka patti ka jitna charai utna stack height rakhni chahiye ya watt ke anusar stack height ko kam ya jyada rakhna hota hai.yedi iska koi formula hai.to ispar vdo bana dijiye
Transformer ki power iska window area aur crossectional area ki product se ata hai.
7:07 primary me 12-0-12 volt hoga aapne 24 kyu bola?
Uski mutabeek 1000/12 = 83 Amp hona chahiye thha
12 0 12 ko kuch esa keh shakte
0 12 24 Center tap ko agar common point manege to hame done sire me 12 volt milaga aur ek sire se dusare sire me jode to total voltage 24 milega
12+12
24
Aur ek positive half cycle me 12 volts hai
To 40 ampere ek 12 volt me
Aur negative half cycle me 12 volts 40 ampere
To total ho gaye 80 Ampere
@@ELECTROGYAN Yeh
45/CA(cm²)
7.5/CA(inch²)
rule ka error rate kitna hai? Kitna reliable hai yeh formula?
Mujhe ek 1000 watt k 24 volt wala transformer banana hai inverter k liye. Isliye jawab jitni jldi diye jaye utna behtar hai.
sir aapse request hai Ki mai 12 volt 3 amp ka transformer design karna chahta hu.iska calculation Kaise karenge.ispar ek vid isi tarike banaiye aur samjhaiye. is transformer mei input 220 volt primary aur output mei 12 volt 3 amp hoga.
Sir apne jo bobin select kia hai 4no 4" Isme 7no swg 28tern nahi jayega 17no se 290tern aap is bobin ata dijiyega
Sir app step down transformer ka bhi is tarah se 3steps bataiye.
ruclips.net/p/PLkDrUT797ZxYX4g9WJFILrZ27CGgqipfQ
Mere questions bobbin for exhaust fan for 6 inch exhaust fan which is shading pole motor which diameter 50x50x15mm which we call stator
How did you got (7). TPV=7/bobin area?
Watch my transformer Design playlist
three phase transformer design calculation bataye sir
Agar square wave input hai to TPV ka formula change hoga
Kya please aap 2000va 24v transformer ka winding ka video banavo. Pure sine wave please
3000va/12volt dc opret pur sine wave transform ka full data calculation btay with feedback wire
To fix formula 7 or 8 ya 7.5 kaise nikala jata hai ye fix kyu hai ... Please describe ...Ye confuse karta hai kyuki toroidal TF me 44 ka formula lagta hai....Please ise jarur bataiye....
Agli video me dono ka confusion dur kardunga ki
Toroidal ke liye 42 rule or 44rule kyo use karte hai
EI type core ke liye 7,7.5,8 kyo lete hai
Sir aap stablelizer ka tranformer ka is tarike se bataye.
Kya aap ko multiplication ya division nehin ata hai
Kya aap ko division aur multiplication nehin ata hai
1000 watt= 1000/0.8= 1250-VA . Aur har transformer me kuchh na kuchh loss hi hota hai isliye ek achha quality ki transformer ki efficiency 80℅=0.8 hi hota hai to transfofmer ki power =1250/0.8=1565-VA hi hota hai. To 24v primary ke liye hamko 1565/24=65-A hota hai jis ke liye 4 no swg copper wire se winding karna hoga aur 250v secondary ke liye 1565/250=6.26A hi hota hai jiske liye 14 swg ka copper wire se winding karna hoga.
भाई साहब विडियो तो यु ट्यूब पर मिल जाता है। पर मटेरियल कहा मिलता इसके अॅड्रेस नहीं मिलता
Material IndiaMART pe mil jayega
Lekin jyada lena padega
Nice video. I've a question on transformer. What specifications should I need to make a step-down transformer 230v ac to 130v ac of 1.5 kw/ampere?
e.g. * core and bobbin size,
* wire gauge and turns for both primary and secondary windings.
* Any others things which I forgot to mention here.
I thought that the transformer formula was in metric, such as core square CM. Also gauge of wire formula is as 700circ mils times current times duty cycle. If power not on all times during time period , then the gauge wire can be smaller. circ mils times % duty cycle. Also, if choosing a LARGER core than required, then there is less turns that have to be wound on bobbin because of formula. Assembling a low frequency transformer with E and I laminations can be interleaved, or separated , so as the top I set comes off, so as bobbin quickly removed for rewinding. The separate laminations type requires strap over unit to hold together. The old style radio chokes were like that method.
3:34 aapne apki dusri video me 7.5 value kaha thha
Nice video, One question the output voltage are RMS? Regards.
Yess
hello ;
where does 7 flat rates come from
हम बोबिन ऑनलाइन कहाँ से खरीदें,, प्लीज बताइये
Fast massege hai answer kijiyega....
Jaldi hi apke doubt clear karunga video ke help se
Wait......for the video
ruclips.net/video/-nYorL4WI1Y/видео.html
Good video my friend. I like to wind a sine wave transformers 12 Volt DC to 220 volt ac 2000 or 2500 watt. Kindly help me
Core nehin milega 210A ki swg ke liye
D. C me power = v×i hota hai lekin ac me power= v×i×pf hi hota hai
Sahi hai par AC wala formula single phase ke liye hai
VxIxPF
Please share me the database of swg core and turn per voltage please share me the database so I can used for making or share me the links I can download it please share me
koi tutorial ya book hai
Pehla formula wrong hai. Transformer ki power handling capacity iska window area aur crossectional area ki product se nikala jata hai.
include power factor
Why is title in English if the video is Hindi?
Thanks for reminding
Let me change to hindi
😊
I need pdf sir
Bhai ye square wave hai
Please help me