Or agar ek slab jo dusre slab se attach hai.. or agar ek slab ka shorter span dusre slab k shorte span se perpendicula hai to main bar or distribution mai dono slab mai kaise lagayenge..plzzz btaiye sir..
Sir self weight of perapet me muje dout he kyun ki weight= volume* density hota he lekin apne sirf width or height hi multipley kiya he or sir slab me bhi muje dout he thikness* density kese aa sakti he usse weight nahi pta chalega
Good content sir, because this load reaction Automatically calculated by etabs and stad pro softwares, but we need this for some places. Sir i having dout about formula where ( Lx / 3), in any case 3 is constant or not?
Sir i think you put the wrong value of floor finish load Because assumed is 1.5KN/M^2, this value is for 1 SqM of slab and our slab was 15 SqM, please look at that is it correct or not
Sir size of columns or beam Hame design karne ke liye assume karna padega ya fir design ke baad size pata chalegi 🙄🙄 Hamesha assume karna chahiye Column ki placing kaise karte hai
Sir..mere dilpoma in architect h..Or b.tech in civil engineer..3year job experience h... abhi 6month se khud ka work start kiya h to architecture related koi books hoto guide kriye sir meko...🙏
Sorry g Maine pura Deka to pata chala ki fos to sab jagah lekar chal rahe hai to last mai jo column par load ka result aayega uska fos se multiply nahi karenge Ok g
👍👍👍👍 Sir , which Footing is Best for G+3 Building ?? Trapezoidal or Step Footing?? Kindly make a Detail video on Footing Design for G+3 with Live Site .
Very nice sir ji👍
Good job 👍
beautiful sharing
Thanks for uploading this video which i said in comments of previous video
Thanks you very much sir
Sir slab mai main bar or distribution mai kaise extend hoti hai plzz us par video banaiye...
Not understand?
Sir iska second part b provide kijiye
Thanks sir
Or agar ek slab jo dusre slab se attach hai.. or agar ek slab ka shorter span dusre slab k shorte span se perpendicula hai to main bar or distribution mai dono slab mai kaise lagayenge..plzzz btaiye sir..
Longer side distribution bar aayenge or short span m main bar ke hisab se lagayenge
Good
Bhaya ghar banane ka puri proses step wise bataiye 1000 sqft ka
Can I get the software of civil design.
सर इतने कम्प्लेक्स क्यालकुलेसन तो आजकल जरुर कम्प्युटर सफ्टवेर से किया जाता होगा, नही?
Sir self weight of perapet me muje dout he kyun ki weight= volume* density hota he lekin apne sirf width or height hi multipley kiya he or sir slab me bhi muje dout he thikness* density kese aa sakti he usse weight nahi pta chalega
🔥🔥
Good content sir, because this load reaction Automatically calculated by etabs and stad pro softwares, but we need this for some places. Sir i having dout about formula where ( Lx / 3), in any case 3 is constant or not?
No brother 3 is not constant ....3 is the length of the traingular side.
@@washidali2061 sir LX is shorter length, what about that denominator 3, i asking about that?
Sir i think you put the wrong value of floor finish load
Because assumed is 1.5KN/M^2, this value is for 1 SqM of slab and our slab was 15 SqM, please look at that is it correct or not
👌🏼👌🏼
slab load= thickness* density
total weight= self weight*floor finish* live load*water proofing* Fos
parapet wall weight= b*h**density*Fos
main wall= l*b*h*density*Fos
beam weight= b*d*density*Fos
Sir size of columns or beam
Hame design karne ke liye assume karna padega ya fir design ke baad size pata chalegi 🙄🙄
Hamesha assume karna chahiye
Column ki placing kaise karte hai
Total load mai 9.1 se multiply kyu hua sir last mai ?
Sir..mere dilpoma in architect h..Or b.tech in civil engineer..3year job experience h... abhi 6month se khud ka work start kiya h to architecture related koi books hoto guide kriye sir meko...🙏
Sir jee Jo coulmn ka load aya usme f.o.s se multiply karna hoga kiya
Yes
Sorry g Maine pura Deka to pata chala ki fos to sab jagah lekar chal rahe hai to last mai jo column par load ka result aayega uska fos se multiply nahi karenge
Ok g
I wonder why parapet wall load is not subtracted from half load of b1 and b2 in the case of first and ground floor?
Sir pdf upload kr digiye
Column self weigh mai 9.1 se multiply kyu hua
Fit m btao
Sir muje job krni h mene 2018 m pass ki h or m kya kru smj nhi aa rha h ab bolte h fresher nhi experience walo ko hayr krte h 😭
👍👍👍👍
Sir , which Footing is Best for G+3 Building ?? Trapezoidal or Step Footing??
Kindly make a Detail video on Footing Design for G+3 with Live Site .
Trapezoidal always
Trapezoidal footing
Sir I.S. Code, technically norm and specification of any item for building send video footing to slab,How to quantity calculated for any item building
Confusing video
weight = LxBxHxdensity . but you put the formula BxDxdensity . Do correction
40 /32 fit area me g+3 ka desine +plan bnane me kitna fee lgega . please btaeeye . your watsapp no please