Rotating rectifier assembly (RRA)

Поделиться
HTML-код
  • Опубликовано: 18 янв 2025

Комментарии • 37

  • @InselRectifiersIndiaPvtLtd
    @InselRectifiersIndiaPvtLtd 7 месяцев назад +1

    Insel Rectifiers India Pvt Ltd is the proud manufacturer of the RRA

  • @skrahim3579
    @skrahim3579 Год назад

    very good information

  • @datakomgensetcontrollertec1306
    @datakomgensetcontrollertec1306 2 года назад +1

    hello dear thank you for your effort .. could you please explain how to choose diodes for alternator because in the market i found diodes 15 a 20 a 25a and 30 ampere so how to know the suitable diode for 50 kva alternator for example ?

    • @practicalelectrical9416
      @practicalelectrical9416  2 года назад +1

      Diode rating is actually determined by the amount of current flowing in main rotor.
      For 50 kva normally 25 amps diode is used.

  • @lomeshlonshikar9798
    @lomeshlonshikar9798 3 года назад

    Which types of diode normally used?

  • @ShyamSundar-qy6yz
    @ShyamSundar-qy6yz 3 года назад

    Thank you u explained very well of RRA.
    I hav an alternator of 40KVA with kirloskar RRA-7 Model. I have problem of sudden drop of voltage or sudden increase of voltage while running. Is this problem related to RRA ?
    PLEASE REPLAY

  • @raghunandanpandey3753
    @raghunandanpandey3753 2 года назад

    Very nice video per sir ji sound nahi aa rahi hai

  • @umehmmaduabuchi7879
    @umehmmaduabuchi7879 Год назад

    Do a video on how to test with a multimeter

  • @electricalmrts4497
    @electricalmrts4497 2 года назад

    What is the type of RRA Unit you shown 2nd item?

  • @darshanmodi5757
    @darshanmodi5757 4 года назад +1

    what is use of rectifier plate ?
    Is it carry the current ?

    • @yuvarajvelmuruganmudaliyar
      @yuvarajvelmuruganmudaliyar 4 года назад

      When a brushless alternator is rotated the main rotar exciter produces AC output. The generator part of the armature coils need dc supply to create electro magnetic fields. So that ac supply is induced in generator stator coils.
      ruclips.net/video/fEn56i5SYDc/видео.html

  • @alainstudio9878
    @alainstudio9878 2 года назад

    Hi, well explained, one question, what can happen if u replace a diode with different polarity, I mean +ve one on negative side. Will it cause exciter coil burn?

    • @practicalelectrical9416
      @practicalelectrical9416  2 года назад

      alternator will work fine on NO LOAD . but on load it will not produce desired voltage.

  • @elumalai-007
    @elumalai-007 3 года назад

    Which condition RRA fault happen?? how to find ?

  • @BhupinderSingh-fu8yj
    @BhupinderSingh-fu8yj 4 года назад

    Nice

  • @mirzamukhtar1741
    @mirzamukhtar1741 4 года назад +1

    12 divod exiting rotor winding daygram 4 set ky 6phas hain please betain

  • @javithhussain2999
    @javithhussain2999 5 лет назад

    Bro i have one doubt if rra is not work the generator not produce voltage? can u let me know if u see this comments

    • @practicalelectrical9416
      @practicalelectrical9416  5 лет назад

      If rra dt work then u will get residual voltage which will not be more then 50 v ac

    • @javithhussain2999
      @javithhussain2999 5 лет назад

      @@practicalelectrical9416 two months before my site generator blast avr when i checking controls unfortunatly one person adjusted voltages variac then avr blast then we quite three months the work after three months i replaced good avr yet we start the generator then we didn't get voltage in panel 380v so i guessed that moment it could be rectifier problem so i need your suggestion how to get through it ?

    • @practicalelectrical9416
      @practicalelectrical9416  5 лет назад

      @@javithhussain2999 how much voltage u get now?

    • @javithhussain2999
      @javithhussain2999 5 лет назад

      @@practicalelectrical9416 our pannel didn't show the voltage it might ve sorted of voltage we didn't check because of my site government authority if i touch anything need to ask permission i check avr is good then we didn't make sure voltage inspire we have checked panel which didn't show anything apart from power factor

    • @javithhussain2999
      @javithhussain2999 5 лет назад

      My question generator running rated speed is OK
      My doubt scr problems not 100% if i can i have to conform clearly any femilier person....

  • @raghunandanpandey3753
    @raghunandanpandey3753 2 года назад

    Sir ji Hindi video bhi banaya

  • @fenglicoy5249
    @fenglicoy5249 5 лет назад

    How to install deoda generator marathon

  • @themysteryofparanormal707
    @themysteryofparanormal707 4 года назад +1

    Is video ka bhi hindi version de

  • @jpsahni1338
    @jpsahni1338 3 года назад

    You are good explained but sometimes sound is off so don't consider me, what are you speaking?

  • @shoebahmad2283
    @shoebahmad2283 5 лет назад

    Sir aap ka phone number

  • @bharatpandya636
    @bharatpandya636 4 года назад

    Plize Hindi pich

  • @ManojKumar-kc6ig
    @ManojKumar-kc6ig 5 лет назад

    hindi language