सर आप वीडियो बहुत ही सुपर जानकारी पूर्वक सर मेरी आपसे एक रिक्वेस्ट है कि आप एक वीडियो वीआरएफ एसी का इंस्टॉलेशन और पाइपिंग किस तरह की जाती है फुल वीडियो बनाएं इस विषय पूरी जानकारी एकदम बार किस से किस तरह टर्नर एज ब्राइटनेस कैलकुलेट किया जाता है इस विषय पर एक फुल जानकारी वीडियो बना इंस्टॉलेशन से इंस्टॉलेशन से संबंधित जिसमें आप एकदम एकदम बार की से 🙏🙏🙏🙏🙏
Hello Royal 👋👋👋 brother 👋💙💙💙 I miss you where were you see you after long time please upload video daily ok good luck 😘💞💞 & God bless 🙏🙏🙏🙏🙏 you because you are good Man
Bhai mai aapka video 2 saal se dekhta hoon Abhi pickle 5 maheene ke under Maine mitsubishi vfv city multi ka control pcb 3 baar replace kiya baar kyu khrab ho jata hai maloom nahi kuch trik ho to batana Bhai Problem ye hai ki usme jo diplay Hota h o off ho jata hai filter pcb se supply 220v ac aata hai lekin DC 330v nai aata hai
Communication wire is connected to the branch box . This wire brings signal to branch box and open the port for refrigerant line if it’s is a 3 pipe system. If 2 pipe system communication wire is connected between indoor units as a parallel connection and last end will be connected to the outdoor unit.
सर आप वीडियो बहुत ही सुपर जानकारी पूर्वक सर मेरी आपसे एक रिक्वेस्ट है कि आप एक वीडियो वीआरएफ एसी का इंस्टॉलेशन और पाइपिंग किस तरह की जाती है फुल वीडियो बनाएं इस विषय पूरी जानकारी एकदम बार किस से किस तरह टर्नर एज ब्राइटनेस कैलकुलेट किया जाता है इस विषय पर एक फुल जानकारी वीडियो बना इंस्टॉलेशन से इंस्टॉलेशन से संबंधित जिसमें आप एकदम एकदम बार की से 🙏🙏🙏🙏🙏
Hello Sachin bhai
Assalamualaikum Bhai hame bhi Daikin company mein vacancy dilwa dijiye
Hello Royal 👋👋👋 brother 👋💙💙💙 I miss you where were you see you after long time please upload video daily ok good luck 😘💞💞 & God bless 🙏🙏🙏🙏🙏 you because you are good Man
SIR konshi coppar paip me kitanaa gus jayega r410 1 miter me
Welcome back Royal guys
Bhaut dino ke baad....
Good work
Bhai mai aapka video 2 saal se dekhta hoon
Abhi pickle 5 maheene ke under Maine mitsubishi vfv city multi ka control pcb 3 baar replace kiya baar kyu khrab ho jata hai maloom nahi kuch trik ho to batana Bhai
Problem ye hai ki usme jo diplay Hota h o off ho jata hai filter pcb se supply 220v ac aata hai lekin DC 330v nai aata hai
Where are you working here
Tell me how to fasten pipe line,,,,,
Please give a video how to use R-141 gas.
Paiping size konsa konsa hota uska video banke dalo na bhai pls
Bhai vrv main communication wire ka kea kam hotta hay ek video me batao
Communication wire is connected to the branch box . This wire brings signal to branch box and open the port for refrigerant line if it’s is a 3 pipe system. If 2 pipe system communication wire is connected between indoor units as a parallel connection and last end will be connected to the outdoor unit.
Bhai aquret bender se bend mejerment leke bend kese kare us par vidieo banavo please
Super
Better employee
Good evening
Bhai mughe VRV ki Piping aata hai.Are mai Ductable Ac installation kar leta hu...
Sir ham hambhi kam karna chahte he
Hi bro