Ipad 5th Generation A1822 No Power, Not Charging FIX.
HTML-код
- Опубликовано: 13 дек 2019
- HOT AIR
Quick 861DW Hot Air Station: www.iparts-4u.co.uk/quick-861...
SOLDERING IRON
Hakko FM203: www.hakko.co.uk/fm-203-solder...
Hakko Micro Pencil : www.hakko.co.uk/fm2028-01-sol...
Hakko Soldering Twezzers : www.hakko.co.uk/fm-2023-mini-...
Hakko Micro Tip T30-I: www.hakko.co.uk/t30-i-conical...
Hakko Micro Tip T30-J Angled: www.hakko.co.uk/t30-j-angled-...
MULTIMETER
Fluke 17B+ Multimeter: www.iparts-4u.co.uk/fluke-17b...
Cheap Multimeter: www.ebay.co.uk/itm/Victor-DIG...
MICROSCOPE
AmScope SM745NTP 7X-45X: www.ebay.co.uk/itm/AmScope-SM...
0.5x Barlow Lens: www.unionrepair.com/0.3x-0.5x...
144 LED Light Ring: www.unionrepair.com/kaisi-k-d...
OTHER TOOLS
DC Power Supply: www.ebay.co.uk/itm/0-30V-0-10...
iPower MAX : www.iparts-4u.co.uk/qianli-ip...
Qianli Stencils Pack: www.iparts-4u.co.uk/qianli-3d...
Qianli Glue Removal Tool 007: www.iparts-4u.co.uk/qianli-si...
Qianli Ic Removal Tool 009: www.iparts-4u.co.uk/qianli-ch...
Website: www.itzone.ie
Facebook: itzone.ie
#datarecovery #microsoldering #boardrepair #mailin #b2brepair Наука
Great video. Have a deep discharged battery and no boot logo or any graphics. Power cycling @ 70-280mA. Will not cold boot / reset. Will open it up and check for possible bad caps. Thanks for posting!!
You guys are the best. Unfortunately, I don't have tools like that. But thanks for explaining.
fantastic
Saludos compañero me sirvió muchísimo tu video muchísimas gracias por el aporte
Nice
Great video
Thanks
Nice fix. What was the liquid you were using? And that was a butane torch?
how much will this cost' and were do you t think I can get my iPad charging problem fixed?
I have an A1822 with a short, draws 830ma. At 5:50 that diode marked "BF" is getting hot. If I remove it, no power. I replaced it, but no change. What am I doing wrong?
Perhaps a late comment but this means something after this diode is consuming too much current. With no power, check the resistance to ground at connection after this diode. You may have a shorted capacitor. You can find it with an adjustable power supply set to 1 volt but 3-5A and IPA (alcohol). The IPA will evaporate faster when the injection is done. That is the shorted part.
@@kumarbhatia6566 Many thanks. I still have the iPad somewhere, I'll have another go at it. Thanks for the tip.
Scusami tanto se fai i video di dimostrazione dovresti far vedere anche agli altri il tutto noi vediamo solo te da lontano che lavori.