How to solve error L4 | Inverter Heatsink | Daikin Super inverter

Поделиться
HTML-код
  • Опубликовано: 7 окт 2024
  • Brand : Daikin Super inverter R410a
    Model : RZR125MVMG
    Error : L4
    Cause : Inverter pcb never fix properly, screw missing and never apply compound by contractor.
    Action : apply heatsink compound and retighten heatsink cover.
    #bonmj #airconditioning #daikin

Комментарии • 30

  • @youyangtee5763
    @youyangtee5763 16 дней назад +1

    Good and clear explanation. Thank you for your coaching.😊

    • @BonMj
      @BonMj  14 дней назад

      You are welcome!

  • @mar95mj52
    @mar95mj52 15 дней назад +2

    Hope you always in good health sir. Thanks for the education

    • @BonMj
      @BonMj  14 дней назад

      Thanks 🙏

  • @mohammadsobuj7027
    @mohammadsobuj7027 2 дня назад +1

    good job sir ❤❤❤

    • @BonMj
      @BonMj  2 дня назад

      Thanks

  • @БахадурЭргашев
    @БахадурЭргашев 15 дней назад +1

    Очень познавательное видео спасибо вам мистер Bom !

    • @BonMj
      @BonMj  14 дней назад

      Thanks 👍

  • @jamestan7901
    @jamestan7901 16 дней назад +2

    Thank u Sir

    • @BonMj
      @BonMj  16 дней назад +1

      Welcome

  • @mohammaduvais3485
    @mohammaduvais3485 16 дней назад +1

    Very good information

    • @BonMj
      @BonMj  16 дней назад +1

      Thanks bro

    • @mohammaduvais3485
      @mohammaduvais3485 16 дней назад +1

      @@BonMj I am seeing your video for the India I am waiting your video for the India sir your r very good information 👍🏻

    • @BonMj
      @BonMj  16 дней назад

      @@mohammaduvais3485🙏🙏Thanks😊

  • @mahiyt9113
    @mahiyt9113 11 дней назад +1

    It's use full thank bose🙏🏻

    • @BonMj
      @BonMj  9 дней назад

      Welcome 😊

  • @Nawabbeg-i3g
    @Nawabbeg-i3g 16 дней назад +1

    Sir this peast verry important for mother bord i p m many more

    • @BonMj
      @BonMj  16 дней назад

      👍👍

  • @arifbabulotapalkatti7643
    @arifbabulotapalkatti7643 15 дней назад +1

    Good job 🎉, bon which connector u fixed bluetoot checker

  • @Lee-mu2jc
    @Lee-mu2jc День назад +1

    老板请问哪里可以买到 那个药膏 谢谢

    • @BonMj
      @BonMj  День назад

      上网可以买到compound heatsink

  • @janshaw5472
    @janshaw5472 15 дней назад +1

    这个是用gas 的温度给电板降温是吧

    • @BonMj
      @BonMj  14 дней назад

      👍👍👍

  • @Dean-xz9uo
    @Dean-xz9uo 15 дней назад +1

    Hey, have you ever come across a c6 daikin fault?

    • @BonMj
      @BonMj  14 дней назад

      Check field setting or fan motir

  • @lazyinvestor11
    @lazyinvestor11 15 дней назад +1

    Hi bon. Can I engage your service? I pm your mail but no reply. I am using starmex system 3 mxy3G28VA2. Room 1 is no cool air when turn on but when I touch ev coil indoor at room 2 the coil is so cold. Already replaced control board but still issue persist.

    • @BonMj
      @BonMj  14 дней назад

      May the LEV valve problems

    • @lazyinvestor11
      @lazyinvestor11 13 дней назад

      @@BonMj thank you bon. Will the ring magnet be helpful?

  • @Louisyongcool2328
    @Louisyongcool2328 14 дней назад +4

    Too many cowboy tech install the PCB and receive the money and go never care about the customer that bad.

    • @BonMj
      @BonMj  14 дней назад

      👍👍👍