it is a piece of cake to understand it.. but no one is ready to teach others. you are doing such an amazing job,, I have no words to thank you. I'm in search of the calculation of water supply and pumps also. if you can help me I will be very thankful to you.....once again thank u...
Hi, Sir. I've commented before and I'll say it again: thank you for your uploads! As a young engineer I truly find your videos highly valuable and I continue to recommend your channel to colleagues and other graduates in this field! Please can you let me know whether the domestic water supply pipe sizing procedure is the same as this drainage sizing? Please kindly continue the good work, you are the best MEP resource on RUclips right now and with time your channel will grow as you continue to upload the wonderful content you do!!!
Dear Samuel Water supply pipe sizing procedure is different because we use different tables and charts for water supply pipe sizing. I already made video on water supply pipe sizing procedure that's already uploaded on my channel using IPC (international plumbing code) standard. Kindly refer to that video on my channel
Its very interesting & educational video especially for those bigger projects that we encountered during calculation needed by the client. Thank you sir & more power to you. Olryte.
BUT BROTHER I'M confused because in drainage system we take separate pipe for water closet (wc) and waste pipe for all other things, is'n it.......but you calculate including water closet load unit? how
Hi...this being a single stack system, don't you recommend the sovent ! Also what about stacks for Towers higher than 9 stories, may be like 50 stories...or may be a case study of burj Khalifa...! Also why is that run out included, can we take it vertical w/o run out ?
your videos r really helping us....will u help me i'm not able to draw sanitary pipe with negative middle elevation in a mep project it show "none of the elements are visible in floor plan:1 - Plumbing View and so on.....plzzzz help to fix it...i'm a beginner
Thank you Sir , i watched all your videos during this lock down & gain so much knowledge from it . can please make video on Kitchen Ventilation and its duct sizing .
What if I have only 9 f.u in my second floor branch and only carried by the vertical stack. Do I use 2 1/2 dia Sanitary stack, but the code says, for wc it can't be discharge below 3" pipe since wc drain is 3".
Thanks for your valuable info sharing. Above u mentioned 3 points in Fixture Unit. 1- Rate of discharge,2- Time of operation,3-frequency of use of fixtures.so how to know these points or there values.
At 6:22 I am glad for the level of detail that you put into this presentation but I really gotta say that the reading and re-reading is getting annoying at this point. You have repeated yourself too many times in my opinion. Remember that we can rewind
I have one problem, I have flow rate of drainage system and, I want to calculate pipe size. Q=AV, But I could not find the velocity char from code book please provide me that chart.
how much pressure rating of the cpvc pipe of 5 inch is advised for my one floor home, . here in my place bandicoot problem is very much, they have damaged 30 years oldmud pipes.
it is a piece of cake to understand it.. but no one is ready to teach others. you are doing such an amazing job,, I have no words to thank you. I'm in search of the calculation of water supply and pumps also. if you can help me I will be very thankful to you.....once again thank u...
Syed you are simple and concise, I love your tutorial, it's great.
Hi, Sir.
I've commented before and I'll say it again: thank you for your uploads! As a young engineer I truly find your videos highly valuable and I continue to recommend your channel to colleagues and other graduates in this field!
Please can you let me know whether the domestic water supply pipe sizing procedure is the same as this drainage sizing?
Please kindly continue the good work, you are the best MEP resource on RUclips right now and with time your channel will grow as you continue to upload the wonderful content you do!!!
Dear Samuel Water supply pipe sizing procedure is different because we use different tables and charts for water supply pipe sizing. I already made video on water supply pipe sizing procedure that's already uploaded on my channel using IPC (international plumbing code) standard. Kindly refer to that video on my channel
Such an amazing explanation sir. Thanks
Very good. Well explained
I really appreciated your explanations. It is very helpful. Thank you bro. I wish you had architectural plan beside you while elaborating.
thank you sir, you are doing a great JOB. please do more videos on PLUMBING
Sure
@@MEPEngineeringTutorials
Masha Allah sir , that's a great job.
May I know what are the software's doni get if I enroll . please
Send an email on syedmuhammadw@gmail.com to get list of softwares
Amazing, Thank you for sharing your knowledge. Keep going,GOD bless you.
Valuable content. Thanks
Thank you Brother/Sir.
Awesome Explanation.
You have cleared my Doubt it was like Rocket science.GOD bless you& Your family Brother/Sir.✍🏻🇦🇪
Great video ❤. Very informative
Excellent explanation dear! God bless.
Excellent video
Would request more videos on plumbing
Sure
Thanks for the knowlege..Keep it up👌🏼
Superb explanation sir. Thanks 👍
pls do more videos on plumbing...waitingfor more videos sir
Its very interesting & educational video especially for those bigger projects that we encountered during calculation needed by the client. Thank you sir & more power to you. Olryte.
thank you very much sir for very informative lectures like these....
Awesome explanation sir
a simple way of explanation and yet I learn a lot,, keep sharing your knowledge,,, thanks and more power.👍👍
Good presentation !!! Nice work.
BUT BROTHER I'M confused because in drainage system we take separate pipe for water closet (wc) and waste pipe for all other things, is'n it.......but you calculate including water closet load unit? how
hi sir can i suggest your next topic is septic tank sizing .thanks
pls do more videos on plumbing
Very helpful
Helpful for my project
A great explanation waqas bhai..... also please explain the plumbing tank OHT , ST , UGT design and pum selection for the same awaiting
Very Nice video, Can you please also make a video for sizing vent pipes.
Yeah sure I will make it soon
what is the name of the code that you use it in this video
Thank you so much very useful ❤️
As salamu alaikum bhai....please make a video on Revit plumbing also.this will help us a lot.thanks for your every video
Walikumsalam. Yeah sure
it is rally helpful tnx
Thank you so much... Sir please make a video on daily water demand and plumbing pump selection
There is already a video on this topic you can search on my channel. Thanks
@@MEPEngineeringTutorials but how to saprate domestic and flushing demand
thank you and thank you :)
do videos on heater selection pumps selection PRV selecton videos pls do
Hi...this being a single stack system, don't you recommend the sovent ! Also what about stacks for Towers higher than 9 stories, may be like 50 stories...or may be a case study of burj Khalifa...!
Also why is that run out included, can we take it vertical w/o run out ?
Can you tell which IPC edition is this?
Please tell me how much slope in mm (1:100 or any value ) for 1/8 inch slope ?
I can’t find it out in internet...
Thank you for the information, i have to ask, what about the vents sizing?
Very interesting lesson
Which Code do you use in this project please?
ASPE and IPC
Thank you sir for always making valuable video
Please upload other codes sizing
I wish also knew how to calculate manhole & septic tank size too
your videos r really helping us....will u help me i'm not able to draw sanitary pipe with negative middle elevation in a mep project it show "none of the elements are visible in floor plan:1 - Plumbing View and so on.....plzzzz help to fix it...i'm a beginner
is this is as per IPC or ASPE or UPC or can we use it for all the above
thank you, please include the chart in your download section used for calculation
thank you
bro, can u provide us the excel sheet for practising or getting all standard information
Thank you Sir , i watched all your videos during this lock down & gain so much knowledge from it .
can please make video on Kitchen Ventilation and its duct sizing .
Sure I will make it soon
Can you please share the ipc standard tables
What if I have only 9 f.u in my second floor branch and only carried by the vertical stack. Do I use 2 1/2 dia Sanitary stack, but the code says, for wc it can't be discharge below 3" pipe since wc drain is 3".
Do you share your tables with the members?
Yes I do share with members. Please send an email to syedmuhammadw@gmail.com for requesting data. Thanks
Sir, which code have you used for getting those standard tables?
ASPE code I have used in this video, but procedure is same using IPC (International plumbing code) and UPC (Uniform plumbing code)
Good
can you please provide the drawing and excel sheet included in the vedio
Thanks
Hi bro how r u
Thanks for your valuable info sharing.
Above u mentioned 3 points in Fixture Unit. 1- Rate of discharge,2- Time of operation,3-frequency of use of fixtures.so how to know these points or there values.
Hello, sir. Can I use this video to present in class?
Yes you can use it
At 6:22 I am glad for the level of detail that you put into this presentation but I really gotta say that the reading and re-reading is getting annoying at this point. You have repeated yourself too many times in my opinion. Remember that we can rewind
What is the maximum number of horizontal branches for each stack?How about the pipe size of the vent stack as shown to your example?
❤❤❤
What IPC code you are referring Sir unable to find it
I would like to get full details about list of price material
Kindly send a price inquiry email on syedmuhammadw@gmail.com to get price details
How can I get these tables
By joining channel membership. Thanks
Is this excel file available?
Yes Andrew olson it's available. All you have to do is to take channel membership by clicking join button on my channel. Thanks
I have one problem, I have flow rate of drainage system and, I want to calculate pipe size. Q=AV,
But I could not find the velocity char from code book please provide me that chart.
what about 1:100 slope
Sir all to all video Urdu m banyae kindly
Amazing Explanation sir. I would like to ask you, can we convert Drainage Fixer unit to flow like M3/hr or GPM???
Units of Drainge fixer units???
Of course we have to convert drainage fixture units to flow (GPM) in order to proceed for drainage pipe sizing
@@MEPEngineeringTutorials thanks for reply sir, How to convert drainage fixture unit to GPM. For 1 fixture unit WC how much GPM should be considered.
You didn't explain how to consider slope direct 1/8 you said
Sheet attached not having any data please kindly do the needful engineer.
Dear Mani this is CR material can't be shared that's why I didn't add tables in sheet. I hope you understand
how much pressure rating of the cpvc pipe of 5 inch is advised for my one floor home, .
here in my place bandicoot problem is very much, they have damaged 30 years oldmud pipes.
Please send me mep software link
Kindly join RUclips channel membership to get access to required material. Thanks
dear sir, kindly share me execel. we already pay
@Keding bao what's your email address?
waqas bhai plz check ur mail
Total wrong video, you have mistaken totally
If so, explain yourself
pls do more videos on plumbing
pls do more videos on plumbing
pls do more videos on plumbing