How to read beam reinforcement drawing | typical beam reinforcement details

Поделиться
HTML-код
  • Опубликовано: 6 сен 2024
  • #Engineeringtactics
    In this video I discussed about how to read beam reinforcement drawing, typical beam reinforcement details,lapping length, development length, beam reinforcement details etc.
    Engineering tactics
    Blog: ENGINEERING TACTICS
    engineeringtac...
    Follow me in INSTAGRAM: / asifansari131
    FACEBOOK account: www.facebook.c...

Комментарии • 183

  • @syedziauddin8685
    @syedziauddin8685 10 дней назад

    Sir, i salute you bht badiya samjaya hai apne kamal ho sir ap kamal. zindagi bhar nhi bhulunga. dil kara hai kai bar bar video dkun thanku.

  • @jithinprem4243
    @jithinprem4243 5 лет назад +10

    Bai ..I am here in Dubai past 12 years..m architectiral..but now I statred to do structural also..thanks for sharing this usefull knowledge..

  • @santoshilal6225
    @santoshilal6225 2 года назад +2

    Sir your information is very good ☺️ please continue information .I am thankful to you

  • @mdimran-fm1xx
    @mdimran-fm1xx 2 года назад +2

    Bahoot behtarin bhai

  • @SunilKumar-qn6og
    @SunilKumar-qn6og 6 месяцев назад +1

    Explained very nice

  • @amlan0921
    @amlan0921 3 года назад

    Jite bar dekhun ye video lage ke aur 500 bar dekhun. Khub bhalo.

  • @mdshahbaz1046
    @mdshahbaz1046 Год назад +1

    Thank you bro..nicely explained 👍

  • @sharmilanaik6441
    @sharmilanaik6441 3 года назад +1

    Thank you sir

  • @vinodr.prasad9069
    @vinodr.prasad9069 5 лет назад

    Very Good Sir Vary nice sir aapne Bahut hi achhe se Samjaya hai Very good information thank you Sir God bless you sir

  • @prawingajbhiye8816
    @prawingajbhiye8816 3 года назад +1

    Thanks.

  • @businessconsultant1229
    @businessconsultant1229 5 лет назад +4

    Bhai maja aa gya....bhai building construction se related full detailed provide krao...

  • @saeelourrahman834
    @saeelourrahman834 3 года назад +2

    Sir you explained very well , keep it up .

  • @Vikash.Doli44
    @Vikash.Doli44 Год назад

    Sir bahut bahut dhanyawad 🙏🙏🙏 aap giyan diya mujhe
    My rad bending Formen hedrabad. Bihar se hu

  • @loveforever.4484
    @loveforever.4484 5 лет назад +1

    Drowning read karna is very easy

    • @ENGINEERINGTACTICS
      @ENGINEERINGTACTICS  5 лет назад

      I know it's easy but...apko ata h lekin kisi kisi ko ni ata h...jb mai bhi fresher tha mujhe bhi ni ata tha usi taraf wo video un freshers engineers k liye h jinhe ni ata.....ap to high level ke ho😊

  • @amlan0921
    @amlan0921 3 года назад +1

    Mind blowing sir . I want to more slab ref detail also. I am a civil engineer

  • @brahmatejaballipalli3392
    @brahmatejaballipalli3392 Год назад

    Good information thank you very much sir,,nice explanation

  • @nasirshaikh4576
    @nasirshaikh4576 5 лет назад +2

    Jazak Allahu Khairan

  • @aimanwar8167
    @aimanwar8167 2 года назад

    Respected sir you show it very better and we impress you lot.
    I want to ask how we put cantilever bottom mid span .please kindly tell its.thanks.

  • @PradeepKumar-kk7uf
    @PradeepKumar-kk7uf 4 года назад +1

    To give very good information.

  • @Sj-wi6ob
    @Sj-wi6ob 4 года назад +6

    Sir you explained very well, can you provide us the AutoCad drawing of this and layout plan?

  • @prafulkindo5445
    @prafulkindo5445 3 года назад +1

    Thanks a lot for such knowledge. U r making my knowledge greater & greater.

  • @rabibhadra2676
    @rabibhadra2676 3 года назад +1

    Very nice video.

  • @mohammadyunus1265
    @mohammadyunus1265 3 года назад +1

    Thanks for this video sir

  • @imteyazali3410
    @imteyazali3410 2 года назад +2

    Dear sir,
    How to calculate the average spacing of ties, if a column having length of 3 m. The spacing of ties in CR (i.e. 1 m) is 125 mm and in NR (i.e. 2 m) is 175 mm.
    Thanks

  • @jagdishbhaivasani3371
    @jagdishbhaivasani3371 Месяц назад

    Fantastic video

  • @manaweralistr7182
    @manaweralistr7182 4 года назад +1

    Sir really excellent video.

  • @raghunathkarale232
    @raghunathkarale232 4 года назад +1

    Thanks.. Very nicely explained. 👍🙏

  • @srikeshrai6579
    @srikeshrai6579 8 месяцев назад

    Yar sahi bol rahe ho .mai foreman hu steel ka rebar ka

  • @bevaraanil6313
    @bevaraanil6313 3 года назад +1

    Thank you so much sir

  • @Heart_Confessions
    @Heart_Confessions Год назад

    Amazing 🔥🔥 mzaa aa gya.... Ek baar 10k likes tap krne ka option btayye sir

  • @mdmusharof4836
    @mdmusharof4836 2 года назад +1

    Thank you sir❤❤❤

  • @bahadurkumar2019
    @bahadurkumar2019 Год назад +1

    Very good sir

  • @RaviYadav-cn9vr
    @RaviYadav-cn9vr 4 года назад +1

    Good sir

  • @PradeepKumar-kk7uf
    @PradeepKumar-kk7uf 4 года назад +1

    Thanks a lot sir

  • @sadhnamahato6641
    @sadhnamahato6641 4 года назад +2

    Helpful 😊

  • @prachiyadav1734
    @prachiyadav1734 4 года назад +3

    Sir,
    I wanted cutting length of Steel of this plan.
    So it's May request to make a video of this plan.

  • @tarzanboy88philippines88
    @tarzanboy88philippines88 4 года назад +1

    This vedio are helpful, thank you this vedio sir.

  • @rumanaparbinssr9811
    @rumanaparbinssr9811 2 года назад

    Nice video

  • @umakantahazarika7204
    @umakantahazarika7204 Год назад

    Excellent my dear sir keep it up.

  • @chennareddyindla2349
    @chennareddyindla2349 4 года назад +1

    Very good.

  • @kamrankhan-qx6ks
    @kamrankhan-qx6ks 4 года назад +2

    a o a sir I do not have words for thanks really you are too excelent teacher your matherad is too good it is very very help full videos sir please tell me how can i contact with you

    • @ENGINEERINGTACTICS
      @ENGINEERINGTACTICS  4 года назад

      Thanx for that lovely comment..u can connect with me by facebook, instagram and email.
      Have in the description.
      One more thing don't write a o a....it's not good
      Assalamualaikum is better and for your salam walaikumassalam kamran khan

  • @reemdubai812
    @reemdubai812 5 лет назад +3

    Dear Ld means developing length but in the bottom or top of beam it's called splice not Ld, take care.

  • @er.sumitrathod2070
    @er.sumitrathod2070 7 месяцев назад

    Can we make continuous beam only with top and bottom bars of size 10 and 12 mm ?
    Without bent bars?

  • @siddarthk9583
    @siddarthk9583 5 лет назад +2

    Super bro👌👌

  • @selflove4273
    @selflove4273 Год назад

    Can u make these drawings with detailing in autocad with clear explanation like this sir

  • @reemdubai812
    @reemdubai812 5 лет назад +2

    Ld is at inside of support

  • @nazeershaikh5773
    @nazeershaikh5773 4 года назад +1

    Thanks❤ nazeer shaikh fitar formen shukriya dost

  • @kannikagowda2905
    @kannikagowda2905 3 года назад +2

    Sir If u could put beam layout, details chart along with this typical beam detail drawing ,it will be helpful for better understanding.plz put

  • @aniketraut8167
    @aniketraut8167 3 года назад +1

    Hello sir..beam steel calculation pr video banaye na..is beam ka .. is video ko dekhkar samj aaya read kaise krte hai.. drawing

  • @autocadsupport7410
    @autocadsupport7410 5 лет назад +2

    bhai bottom extra bar L/5 liya jata hai na....

    • @ENGINEERINGTACTICS
      @ENGINEERINGTACTICS  5 лет назад

      Ni bhai bottom extra bar agr L/5 liye to us bar ki length bhot kam ho jayegi or itni chhoti bar beam ke tention stress ko sambhal ni payegi.....

  • @sandeepprajapati5880
    @sandeepprajapati5880 3 года назад +1

    Sir very very thank you for this information.
    One more request sir please provide this drawing in pdf.
    Please sir..
    🙏🙏🙏

  • @user-mw4ju7ob8j
    @user-mw4ju7ob8j 8 месяцев назад

    Bravo

  • @AbdulWahid-wf4vy
    @AbdulWahid-wf4vy 3 года назад

    Sir agar mai apni said ki duraig ka kuch samajhna chahun to sir aap samjhayenge

  • @adeelfareed9492
    @adeelfareed9492 3 года назад

    very helpful level

  • @civilengineeringfromgoldme3074

    Well explanation

  • @iambsa625
    @iambsa625 5 лет назад +2

    Nice.........m

  • @vinodkarle2630
    @vinodkarle2630 5 лет назад +2

    Staircase.ki.west.slab.ki.thicknes.7inch.se.jyada.ho.jay.to.use.kuch.khatara.to.nahi.hai.na.sir.bataiye.please.

    • @ENGINEERINGTACTICS
      @ENGINEERINGTACTICS  5 лет назад +1

      Koi khatra to ni h but self weight of staircase zyada ho jayega..or agr us staircase 12mm ki steel lagi hui ho to stair ko kuch ni hoga but agr 10mm ki ho to future thoda risk ho skta h due to extra weight. Normally west slab ki thickness 6 inch hoti h

    • @vinodkarle2630
      @vinodkarle2630 5 лет назад

      कन्फूजण.दूर.करने.के.लिए.धन्यवाद.सर.

  • @loveforever.4484
    @loveforever.4484 5 лет назад +1

    Beam me steel ka over laap bhi to hoga bhai

    • @ENGINEERINGTACTICS
      @ENGINEERINGTACTICS  5 лет назад

      Ha bhai overlap bhi hoga jaha steel length kam pad jayegi or uska kaha kaha or lapping de skte h or kyun....wo bhi bataya h

  • @loveforever.4484
    @loveforever.4484 5 лет назад +2

    Bhai kabhi time milega to B.B.S solve ka bhi video Bana Dena bhai

    • @ENGINEERINGTACTICS
      @ENGINEERINGTACTICS  5 лет назад

      Bhai mere BBS pr bhi video banaya hua h ap mere playlist me jaa kr dekh skte h

  • @shalinimundra3042
    @shalinimundra3042 4 года назад +1

    Sir this is standard for all type of continuous,cantilever or simply supported beams?..

    • @ENGINEERINGTACTICS
      @ENGINEERINGTACTICS  4 года назад

      Yes...that is standard for every beam...that's why it's called typical beam Reinforcement details.

    • @zeeshanvirk9633
      @zeeshanvirk9633 2 года назад

      Very informative vido s ❤️

  • @kannikagowda2905
    @kannikagowda2905 4 года назад

    Sir as per is 456 ..span should be span know ..in this typical drawing why have u considered clear span??? And at bottom it's 0.15L from the middle of the support right why have u taken every distance from face of the column???

  • @prabirsamanta7545
    @prabirsamanta7545 5 лет назад +1

    Sir, ish commercial building ka pura construction process ka video banaye, to humlogo ka bohut help hoga sikhne me, jese ki foundation ke bad column ke kinte bad p. Bem dena hoga, kob kob lift ka kam suru korna chaiye, full details... Please sir

    • @ENGINEERINGTACTICS
      @ENGINEERINGTACTICS  5 лет назад

      Ok...mai koshish krunga sari video banane ki construction k uper ....abhi to plinth complete ho chuka h....age kaam hoga to banata hu

  • @DeepakSharma_91
    @DeepakSharma_91 5 лет назад

    Sir apki sari videos achi hoti hai..but jo apne m25 ka design mix kiya usme ye nahi btaya ki farma kaise banega...30 aur 35 ka

    • @ENGINEERINGTACTICS
      @ENGINEERINGTACTICS  5 лет назад +1

      Mai smjha ap kya kahna chahte hai fir bhi clear kr deta hu maine design mix bataya h concrete ka M15 se le kr M40 tak ka jis me ye baya h k apko aggregate kitna liters lena h sand kitna liters lena h 1 bag of cement k liye of use farme me kis tarah convert ktna h.......farma ka size fixed rhta h according to liters jitne liters lag rhe h utne size ka farma le skte h ex 30 liter ya 35 liters ya 40 liters etc

    • @DeepakSharma_91
      @DeepakSharma_91 5 лет назад

      @@ENGINEERINGTACTICS okay thanks sir ...

  • @RoatRahul-yh7pf
    @RoatRahul-yh7pf Месяц назад +1

    0.25L1 ka matalab kya hota he

  • @CivilConstructionWorld
    @CivilConstructionWorld 4 года назад +1

    Sir I am very week in structure work I don't no how do the work with drawing already I am doing work without drawing sir please can u help me. Please can u make easy drawing for structure refocement for beams column and slabs

    • @ENGINEERINGTACTICS
      @ENGINEERINGTACTICS  4 года назад +1

      No problem I already uploaded that type of videos you can watch it that's helpful for you and then you will asked me any doubts about structure.

  • @adityavaidya5720
    @adityavaidya5720 4 года назад +1

    Bhai jaha BM JYADA HOTA H WAHA tension sabse kam hota h .....kuch b bologe matlb or uska reason ye h k top bars ko overlap edges p isliye nhi krte kyunki edges m top m tension aata h jiske karan joints nikl skte h edges p isliye centre n krte h kyuki centre wale portion m top wale region m compression zone hota h jisse joints niklte nhi h 🙏

    • @jagdishvadher3322
      @jagdishvadher3322 3 года назад

      Yes bro and agr simply support beam ho to uska tension zone niche ata hai and compression upr vese hi cantilever beam me ulta hota hai

  • @madhuslifestyle1135
    @madhuslifestyle1135 3 года назад

    L1 means clear length of beam or c/c length??

  • @papiahalder4732
    @papiahalder4732 5 лет назад +2

    Mujhe is book ki nam batay bohot help hogi meri may avi b tech student hun civil

    • @ENGINEERINGTACTICS
      @ENGINEERINGTACTICS  5 лет назад

      Great.....👍
      Ye RCC drawing hai....working drawing jb ap kisi site lagoge to apko bhi aisa hi plan milega isi ko dekh kr hme site reinforcement bar provide krna hota h

  • @Vishalvlogs2271
    @Vishalvlogs2271 4 года назад

    Thank u so much sir this video very helpful for us..

  • @DEEPAKDAS-qo7zm
    @DEEPAKDAS-qo7zm 2 года назад

    Sir plinth beam bbs chaheya.

  • @gbanglanews4643
    @gbanglanews4643 5 лет назад +2

    tkn vai lm from oman vai plz doga kese dwring ka hisab se kartahe plz ak video dije

    • @ENGINEERINGTACTICS
      @ENGINEERINGTACTICS  5 лет назад

      Nice....shabbir bhai....I can't understand whatever you said. Plz say clearly

  • @ajayriyar4531
    @ajayriyar4531 3 года назад +1

    T👍👍👍

  • @ShahbazAli-gp8zl
    @ShahbazAli-gp8zl 2 года назад

    سر چہمبر کی اور مین ہول کی تعلیم دیں ڑوڈ پاٸیپ لاٸین اور اے ٹی سلات کی چہمبر بناٸیں

  • @techcheeta5101
    @techcheeta5101 3 года назад

    Is beam ka bbs bna kar dekha do please

  • @ankitshani5425
    @ankitshani5425 2 года назад

    Ok

  • @lolipanda2763
    @lolipanda2763 4 года назад

    Sir the beam plan I am studying has development length=Ld + 10db
    Ld= lapping length =50D
    (Mentioned in notes)
    Fir apne kuch alag btaya ??? Asa kese

    • @ENGINEERINGTACTICS
      @ENGINEERINGTACTICS  4 года назад

      Lapping length or development length dono same hi hota h...jisko Ld se denote krte hai

    • @lolipanda2763
      @lolipanda2763 4 года назад

      @@ENGINEERINGTACTICS Sir mene edit karke tik kiya h. Plan mai asa diya h

  • @sheikhsadi4813
    @sheikhsadi4813 11 месяцев назад

    🎉❤

  • @mehtabalikhuhro2459
    @mehtabalikhuhro2459 3 года назад

    Sir plinth beam ki elevation bhi read Kara btaye

  • @aejazahmed9048
    @aejazahmed9048 5 лет назад +2

    Plz give me mix design proportion

    • @ENGINEERINGTACTICS
      @ENGINEERINGTACTICS  5 лет назад

      Don't worry design mix proportion video come soon....stay tuned.....

  • @riddhiparmar5521
    @riddhiparmar5521 3 года назад

    Sir, L1 = effective span lena hai ya cler span?

    • @kaakib8841
      @kaakib8841 3 года назад

      Clear span (drawing mein dekho inner to inner length hai L1 l2 l3 sab)

  • @ptcivilconstruction286
    @ptcivilconstruction286 5 лет назад +2

    Sir ye drawing ajay mahale sir ki hai na ?

    • @ENGINEERINGTACTICS
      @ENGINEERINGTACTICS  5 лет назад

      Ri8.....ap jante ho ajay mahale sir ko

    • @ptcivilconstruction286
      @ptcivilconstruction286 5 лет назад +1

      @@ENGINEERINGTACTICS han sir
      Ajay sir vaibhav laxmi builder n devloper k project par kaam kar rhe hai ...

    • @ENGINEERINGTACTICS
      @ENGINEERINGTACTICS  5 лет назад

      Ok....👍

    • @ENGINEERINGTACTICS
      @ENGINEERINGTACTICS  5 лет назад

      Kaha pr hai ye project....or ap us builder k site engineer ho kya

    • @ptcivilconstruction286
      @ptcivilconstruction286 5 лет назад +1

      @@ENGINEERINGTACTICS project vikhroli kannamwar nagar me hai ..
      Main contractor k pas hu
      As a site engg ...

  • @mohdmuzeeb941
    @mohdmuzeeb941 4 года назад +1

    Sir is beam ka BBS or bana ke dikhana please sir

  • @vikramsinghkandaiburu2736
    @vikramsinghkandaiburu2736 3 года назад

    Aap kahte hain ki humein tenson zone par lapping nahi karna hai, aur aap ye bhi kahte hain lapping zone bhi yehi sahi hai aapne diagram jo tenson force discribe kiya tha uske hissab se lapping provide karni chahiye ya nahi

  • @mr.debraj3700
    @mr.debraj3700 5 лет назад +1

    Sir slab ka bari me kuch video vegiye please

  • @tanaymasti6218
    @tanaymasti6218 2 года назад

    App beam ka bbs kasa nekla ga on paper bataya sir

  • @RizwanKhan-hj2ss
    @RizwanKhan-hj2ss 5 лет назад +1

    Is there any job requirement for civil engineer???

  • @IrfanKhan-qs6dq
    @IrfanKhan-qs6dq 2 года назад

    Agar sir Ld+10 ho to ky krn ho gy

  • @ikhlaqkhaliq9782
    @ikhlaqkhaliq9782 4 года назад

    Sir g 7:45 per wo bending moment diagram nhi ha... bending moment positive hoti ha jahan per load zyada ho

  • @ziauddin7948
    @ziauddin7948 3 года назад

    Good beam reinforcement top , bottom & extra bars cutting length & structure #

  • @manjeetkumarmanjeetkumarpr699
    @manjeetkumarmanjeetkumarpr699 4 года назад +1

    Sir dadar ka video bhejiye

  • @loveforever.4484
    @loveforever.4484 5 лет назад +1

    Development length koun h bhai

  • @adityamondal9869
    @adityamondal9869 2 года назад

    Can u pl upload drawing sheet?

  • @causeitsmylife2023
    @causeitsmylife2023 4 года назад

    Sir can you put english subtitles nextime. Please😇😇

    • @ENGINEERINGTACTICS
      @ENGINEERINGTACTICS  4 года назад

      I tried for it but it take much more time to typing and editing....
      Do u know any shortcut method to put subtitles on video

  • @Engrwaleed555
    @Engrwaleed555 2 месяца назад

    Which code is this?

  • @jawidrezayee5672
    @jawidrezayee5672 3 года назад

    Dear sir if you explained it in English it would be great.

  • @Rahbarify
    @Rahbarify 2 года назад

    L1 ki length kaha show kar rha, kaise pata karenge L1 ki length

  • @ezhilarasan3776
    @ezhilarasan3776 4 года назад

    How to calculate Ld

    • @ENGINEERINGTACTICS
      @ENGINEERINGTACTICS  4 года назад

      Ld is already given by the RCC designer on the RCC drawing....like as 40D,45D,50D.....

    • @ezhilarasan3776
      @ezhilarasan3776 4 года назад

      If the cantilever beam is there, we calculate 1.5*L3 on top rebar ?
      Anchorage bar length calculate like 40d ,50d?

    • @ENGINEERINGTACTICS
      @ENGINEERINGTACTICS  4 года назад +1

      For the top bar u should simply calculate the Beam length and Anchorage length as 50D but
      For the top extra bar in cantilever u should take 1.5*L3 thats it no need to take Anchorage length for that. u can cut it as straight.

  • @kalyanghosh994
    @kalyanghosh994 3 года назад

    Hum e ek drawing de sakte hai?

  • @ashraf5814
    @ashraf5814 3 года назад

    Formeni sikhna hai

  • @chetanverma4051
    @chetanverma4051 Год назад

    0.25 ka mm ma kasa nikala