What will happen to U-tube? If a heavy slug is pumped into the drill string and the well is shut ?

Поделиться
HTML-код
  • Опубликовано: 15 сен 2024
  • IWCF Drilling Level 4: e-rigworld.odo...
    IWCF Drilling Level 3: e-rigworld.odo...
    What will happen to U-tube? If a heavy slug of 10 bbl is pumped into the drill string with below-given data and the well is shut by closing BOP and FOSV in the drill string.
    Well TVD: 10000 ft.
    Mud weight: 10 ppg.
    To pull out, dry driller pumps heavy slug. This video will explain what will happen to pit levels and BHP if the slug id pumped into the drill pipe. This video will also explain about what will happen to BHP if a light pill is pumped in the drill string and the well is close.
    Slug density: 16.8 ppg.
    Slug volume: 10 bbl.
    Drill pipe Metal Disp: 0.008 bbl/ft
    Drill pipe Capacity: 0.0176 bbl/ft.
    A. A back pressure of 200 psi will visible on the drill string gauge.
    B. A back pressure of 150 psi will be visible on the annulus gauge.
    C. A back pressure of 200 psi will be visible on the annulus gauge.
    D. A back pressure of 150 psi will visible on the drill string gauge.
    E. The Well is under balance due to a heavy slug in the drill string.
    Well control, IWCF, IADC, Drilling, U-Tube effect
    To prepare for the IWCF exam. Check out IWCF Preparation Course available at our Website.
    ►Our website:
    www.erigworld.com
    www.rigworld.in
    ►Contact Us:
    www.erigworld....
    Subscribe to see more of Well Control, IADC, and IWCF questions on your feed!