  • @jmsaffroy
    @jmsaffroy 2 года назад

    Why is it better to not have the water filter while the boiler is being refilled? Is there a chance that the boiler would not be filled properly? And if that's the case, how would you detect it?
    Thank you for all the useful videos!

  • @nazar7161
    @nazar7161 3 месяца назад

    LCC doesn’t light on in my Lelit Bianca machine but the machine still working ( I guess using last saved inputs).
    Trying to solve this issue (LCC doesn’t display) :
    -->
    When I do reset the machine(power button + (+) ) the machine even doesn’t turn on in this case!
    What are potential problems here please?

    • @lelitinsider2977
      @lelitinsider2977  3 месяца назад

      hi, it can be a problem on the lcc display
      please send a video a care@lelit.com

  • @twojstary_1500
    @twojstary_1500 4 месяца назад

    Hello,
    My LLC display stopped working today in Victoria. Is there any other problem that could occur other than the LLC breaking? For example maybe the connection went loose?

    • @lelitinsider2977
      @lelitinsider2977  4 месяца назад +1

      hi, please try to do a reset as in the video,
      if it doesn't work please send a video at care@lelit.com

    • @twojstary_1500
      @twojstary_1500 4 месяца назад

      @@lelitinsider2977 thank you.
      Unfortunately it didn’t work.
      What are the factory settings of Victoria? Brewing time and temperature?

    • @lelitinsider2977
      @lelitinsider2977  4 месяца назад

      @@twojstary_1500 please send a video at care@lelit.com

  • @10tigre1010
    @10tigre1010 Год назад

    Hello, after resetting the machine, does the total/partial counter doses keep the values as before the reset? (Lelit Victoria OTPGem-114) Thanks

    • @lelitinsider2977
      @lelitinsider2977  Год назад +1

      reset clears partial counts, total counts do not reset

    • @10tigre1010
      @10tigre1010 Год назад

      ​@@lelitinsider2977 Thank you for your response! On the other hand, could you share your opinion about a particular behavior that I observed in my PL92T during the switching-on? Please see ruclips.net/video/DcCAg6EwzrU/видео.html Thanks!

    • @lelitinsider2977
      @lelitinsider2977  Год назад +1

      @@10tigre1010 in the software there are refreshers
      these are to keep the display from freezing between screens.
      these refresh are also inserted when you activate the pump or solenoid valve
      in this case there is heating enable

    • @10tigre1010
      @10tigre1010 Год назад

      @@lelitinsider2977 Thank you again for your comments. Finally, is it normal those blinks can occur sometimes and sometimes not, apparently in a random way? (In my case the blinks after switched-on aren´t always present, I could see that aproximately they appear half of times). Thanks.

  • @shinmarucc
    @shinmarucc 3 года назад

    Hello Mauro, would this also work on Bianca’s LCC?

    • @lelitinsider2977
      @lelitinsider2977  2 года назад +1

      yes, it is the same

    • @michaeljcylmcz1136
      @michaeljcylmcz1136 2 года назад +1

      Hello Mauro, with the bianca do I need to lift up the brewing lever for water going through the group head for 10 seconds and lower the lever in close position waiting for the water refill the steam boiler? Thanks

    • @lelitinsider2977
      @lelitinsider2977  2 года назад

      @@michaeljcylmcz1136 after the reset you have to do it for 30 seconds

    • @michaeljcylmcz1136
      @michaeljcylmcz1136 2 года назад

      @@lelitinsider2977 Thanks lot

  • @apecambodia2521
    @apecambodia2521 2 года назад

    For Kate, is it the same?