Это видео недоступно.
Сожалеем об этом.

Thermostatic expansion valve in Refrigeration system Lec 01 //Thermostatic expansion valve

Поделиться
HTML-код
  • Опубликовано: 26 авг 2020
  • Thermostatic expansion valve
    Thermostatic expansion valve in refrigeration system
    Thermostatic expansion valve with external Equalising line in Refrigeration
    Internal equalising and external equalising line in TEV
    Refrigeration and Air conditioning Full Lecture : 01.
    • What is 1 Ton of refri...
    Refrigeration and Air conditioning Fuol lecture :02.
    • Refrigeration cycle wo...
    Marine Compressors Lectures
    • Marine Compressors Q&A...
    Marine Boiler Q&A MEO Discussion Lecture
    • Marine Boiler Q&A Disc...
    Subscribe and follow The Indian Mariners for Marine Engineering website (IMU notes available ,Marine Engineering Q & A Content.
    theindianmarin...
    Connect with me on My LinkedIn
    / vikash-kumar-54944a1b1
    Connect with me on FB
    / vikash.jyoti.92
    Learn and Grow with Marine Etutor
    Please like Share and subscribe to the channel
    / @searainly
    Lecture By
    Vikash Kumar

Комментарии • 35

  • @searainly
    @searainly  3 года назад +14

    12:45 The Downward force ie Bulb force which try to open the valve and Upward forces ie Evaporating and spring force which try to close the valve.
    Needle stand Balance Equation :
    Bulb force = Spring force + Evaporating force.
    Thankyou!

  • @ankitanandvlogs
    @ankitanandvlogs 3 года назад +1

    Sir I am watching each and every video to clear all doubts and have proper understanding of refer system including my main purpose to clear MEO 4 exam. Thanks sir
    Keep uploading such videos. Really helpful.

  • @arvind9305
    @arvind9305 3 года назад +3

    Another great informative video. Amazing sir.

    • @searainly
      @searainly  3 года назад

      Thank you brother! 👆

  • @irshadansari7538
    @irshadansari7538 2 года назад +1

    Rest , very informative video.

  • @najinkunnath6009
    @najinkunnath6009 Год назад +1

    Superb

  • @rishabjaikumar4095
    @rishabjaikumar4095 Год назад +1

    Sir ,
    when refrigerant come out of condenser and goes to thermostatic expansion valve it has high pressure and low temperature but you have mentioned high temperature and high pressure

    • @searainly
      @searainly  Год назад

      Please refer Basic Working principle of Refrigeration's lecture . Thankyou .stay connected 🙌

  • @mithaleshkumar2486
    @mithaleshkumar2486 3 года назад +2

    Very good lecture explain sir

  • @kshitiz41
    @kshitiz41 5 месяцев назад +1

    Thank u sir

  • @jagdish99_sw
    @jagdish99_sw 8 месяцев назад

    Sir if evaporator load decreases, and there is extra flow of refrigerant in evaporator amd now needle valve is fully closed, so how this extra refrigerant is handled, ??

  • @loneranger2366
    @loneranger2366 2 года назад

    16:33 As per TS diagram temp of refrigerant remains constant as it absorbs only latent heat in Evaporator. But you are saying the temp will increase!!! And it will be sensed by feeler bulb.

  • @sarthakraul361
    @sarthakraul361 3 года назад

    before txv it is HT HP and before evaporator it is LT LP ?? reason is flashing up liquid...can you say more about it sir???

  • @shubhamyejare845
    @shubhamyejare845 3 года назад

    Hii sir, my question is that initially how the sensing bulb senses the evaporator o/L ?
    Because when the valve opens then oly the refrigerant is going to flow no and to open that valve bulb should sense...then initially how it sense when there is no flow

  • @mukhtarahmad4293
    @mukhtarahmad4293 Год назад

    Best explain

  • @artemiosycee1845
    @artemiosycee1845 3 года назад +1

    English subtitles please to all of your videos☺️ please sir. Please

  • @kusanavakaran430
    @kusanavakaran430 3 года назад +1

    Wah sirji.

  • @brainstonm5570
    @brainstonm5570 3 года назад

    Sir y this pe is required? We this internal equliising line?

  • @unknownman4684
    @unknownman4684 2 года назад

    What is degree of superheat sir?

  • @shashanksandy112
    @shashanksandy112 3 года назад +1

    The purpose of drier is to remove moisture, Sir then how it is possible for liquid refrigerant to enter TXV? And also please explain how does temperature outlet of condenser is high?

    • @searainly
      @searainly  3 года назад +3

      HP HT vapour refrigerant enters into condenser.Constant temperature heat rejection (Latent heat rejection ) takes place inside the condenser it mean vapour refrigerant directly converted into liquid refrigerant at constant temperature. & that liquid refrigerant pth TXV.

    • @searainly
      @searainly  3 года назад +3

      And then HP HT liquid refrigerant enters a constricted tube which is the expansion valve. Now similar to the convergent nozzle, the velocity of refrigerant increases which obviously lowers its pressure(Thats why TXV is also act as Pressure reducing valve) Since Temperature is directly related to pressure, the refrigerant’s temperature decreases. This process is a constant enthalpy process.
      And other properties of expansion valve I already made video for d same.
      Thank you!

    • @shashanksandy112
      @shashanksandy112 3 года назад +1

      Thanks alot sir your videos are very much helpful and do make a video on jacket cooling water system.

    • @searainly
      @searainly  3 года назад +1

      Yh sure brother I will cover this topic on my Marine line diagram lecture series.

    • @vaibhavtandon3572
      @vaibhavtandon3572 3 года назад

      @@searainly great explanation

  • @irshadansari7538
    @irshadansari7538 2 года назад

    बहुत complicated कर दिया है आपने ।

  • @irshadansari7538
    @irshadansari7538 2 года назад +1

    डायफ्रॉम होता है सर जी उच्चारण।

    • @searainly
      @searainly  2 года назад

      Sorry my mistake 🙏

  • @nawazsitam9732
    @nawazsitam9732 3 года назад +1

    Sir how i join marine for refrigerarion and air condition .. I completed iti .what next ... Dont mine

    • @searainly
      @searainly  3 года назад +1

      U may join Lateral Entry b. Tech course after completing your Mechanical/Electrical/Electronic Diploma course.

  • @saqlainmahiwal3216
    @saqlainmahiwal3216 3 года назад

    sir aap kis company me placed hai?

  • @elanchezhian.selanchezhian2374
    @elanchezhian.selanchezhian2374 21 день назад

    You are speaking language not understandable ( wasted one). speak international language an English. Easily can understand and you reached short period.