How to install a 4-way ceiling cassette heat pump / AC

Поделиться
HTML-код
  • Опубликовано: 15 сен 2024
  • DIY steps of installing a 4-way ceiling type cassette heat pump / AC in an old house attic.

Комментарии • 90

  • @JC-gd3cc
    @JC-gd3cc 3 дня назад +1

    Loved the music as well. Reminded me of the music they play at the Coeur d' Alene Resort in Idaho.

  • @BungeeRooster
    @BungeeRooster 3 года назад +6

    It's very nice to see your kids helping out. Reminds me of my father making us work with him. Then again I feel bad for the kids because it reminds me of my father making us work with him.

    • @CategoricalImperative
      @CategoricalImperative 2 года назад +1

      Lmao. I have similar ‘mixed’ feelings of helping my father. But I have a lot of experience working with my hands and repairing things now.

  • @matej.m.rejsek8537
    @matej.m.rejsek8537 3 месяца назад

    Nicely done! I love the completely inappropriate music... it's all like, "It's a wonderful spring day and I'm happy to be alive and the tasks before me are being executed smoothly and with competence because I've tried to live my life with grace and fairness." Now if *I* had been installing the same unit the soundtrack playing in my mind would have been death-metal of some sort because it would have been one long series of travails. But seriously, this was nice (and informative) to watch. Thanks for posting it.

  • @eyygurke6081
    @eyygurke6081 Год назад +25

    Finally got it up and running. The only delays we had was because we realized we needed some extra parts (I’ll list that below) ruclips.net/user/postUgkxihMYiJNXcHdbH-7ihymsLz61l7jVyb5O . So we have a loft where our current hvac just couldn’t seem to keep cool during the summer. We have been using a window unit since we bought this house over 6 years ago (all the houses in this neighborhood were built in the 80’s and majority of the houses built like ours use a window unit). I hate window units because they are just so noisy and the one we had really only cools one side of the loft. I had contemplated upgrading our current HVAC, but with all the rising prices these days, it would take years before saving up enough to do that. With the advice of my father-in-law (used to run an HVAC business), he recommended we get an inverter instead. We thought we bought everything we needed, but there were just a few other parts we didn’t anticipate needing (which is what caused most of our delay). My friend and father-in-law did all the work to get it installed and running and now we have nice cool air circulating nicely throughout the entire loft. It is very quiet and even the outside unit is much quieter than our main HVAC unit. Saved ourselves thousands getting this.

  • @MichaelHernandez-lc2wb
    @MichaelHernandez-lc2wb 3 года назад +1

    Spotless work, amazing details and kids helping too, bravo!

  • @David-jq9oy
    @David-jq9oy 3 года назад +6

    Thanks for making the video! I never thought of using a crows foot on a torque wrench to get in tight spaces. Also, I hope you get a new chisel for your birthday. :)

  • @heididecker707
    @heididecker707 3 года назад +1

    I would have you work on my home in an instant! You are so thorough.

  • @techguy2342
    @techguy2342 3 года назад +5

    Crows foot should be at 90 degrees for proper torque. Evacuating should also be done using a micron gauge as the gauge set doesn’t have enough resolution. Otherwise, nice job!

    • @PayNoTaxes0GetNoVote
      @PayNoTaxes0GetNoVote 3 года назад

      Yeah, I caught that too. Thought maybe he accounted for that by doing a rough adjustment in the torque settings. I was hoping to see if the Senville Cassettes had the knock out like the LG's do. I need to steal a little bit of the supply to condition a small bathroom. The Senville units are significantly cheaper than LG and have better low temperature (heating) performance, -13F vs -4F, if the numbers are to be trusted. Do you happen to know if the Senvilles have that option?

  • @thecs6363
    @thecs6363 3 года назад

    Nice work. Well done video. Thank you!
    (Also thank you for not using pleasant music instead of awful cheesy action music!)

  • @786otto
    @786otto 3 года назад +1

    Nice video, whole family is helping.

  • @degenhexican9355
    @degenhexican9355 3 года назад +1

    Love the video and as a mechanic myself love your techniques A+

  • @eschrader
    @eschrader 2 года назад +1

    5:30 the good thing about installing a home AC, everyone is willing to help!

  • @ArthurCui
    @ArthurCui 3 года назад +1

    Nice to have two sons when doing contruction work like this

    • @gazd4812
      @gazd4812 3 года назад

      well, that depends - mine are 2 and 4 years old. LOL

  • @cm0ly989
    @cm0ly989 4 года назад +2

    Excellent job on both the installation and the video!! Thank you!

  • @2LegitTooQuit
    @2LegitTooQuit 3 месяца назад

    @20:19 for anyone wondering there is a bare ground being connected as well that he forgot to mention with the 12/2 wire.

  • @NoorRefrigerationsystem
    @NoorRefrigerationsystem 3 года назад

    Wow Amazing video I love This channel ❤️❤️❤️

  • @dffps129
    @dffps129 Год назад

    nice job. I think code requires braided copper for 220v whip.

  • @jessegarcia7979763
    @jessegarcia7979763 2 года назад

    Awesome video! Thanks

  • @mannyvelez4437
    @mannyvelez4437 4 года назад

    Very neat job. Very clean too

  • @joeltell8484
    @joeltell8484 2 года назад

    what a perfect installation

  • @michael9t
    @michael9t 3 года назад

    Brilliant video. Thank you.

  • @grapeabyss1744
    @grapeabyss1744 2 месяца назад

    No sub 500 micron vacuum? No nitro pressure test?

  • @peterhoward2113
    @peterhoward2113 4 года назад +3

    Hi, I just want to say thanks for this great video! I'm currently installing the same one. do you know what that extra wire in the indoor unit that you left disconnected is for?

  • @erikkovacs3097
    @erikkovacs3097 3 года назад +1

    NM cable is not designed to be run in conduit. You can do it for short straight runs but it gets very difficult very quick. It's just easier and cheaper to run THHN.

    • @Rambleon444
      @Rambleon444 2 года назад

      Can you strip the outer sheath off and then run it through the outside conduit?

  • @jasonclare1481
    @jasonclare1481 2 года назад

    Great video!!!

  • @abaddadproduction8112
    @abaddadproduction8112 Год назад

    Thank you!
    Well done!

  • @Northwest736
    @Northwest736 2 года назад

    Thank you for this!

  • @paxlepham
    @paxlepham 3 года назад

    Great video

  • @peterarthen264
    @peterarthen264 3 года назад +2

    Nice video, but it looks like you are using a crow's foot on a torque wrench. The crow's foot should be at a 90 degree angle to the wrench, your 26 pounds is now more.

  • @mrmanojmj9105
    @mrmanojmj9105 Год назад

    Very Nice...

  • @inhocsigno9151
    @inhocsigno9151 3 года назад +1

    At 11:36 you forgot to wipe your fingers on your pants. Nice video and install.

  • @matthiaslipinski2826
    @matthiaslipinski2826 5 дней назад

    What makes a 4-way cassette 4-way?

  • @babaolowo35
    @babaolowo35 2 года назад

    Thanks 👍

  • @suespony
    @suespony 2 года назад

    How well does this unit heat for you?

  • @Littleshotphotos
    @Littleshotphotos 4 года назад

    Nice work, shows what will need to be done. Can I ask where you found the no woman, no cry piano at the very beginning to 3:00 min?

  • @kentturner8883
    @kentturner8883 Год назад

    No drainage?

  • @calebjensen6664
    @calebjensen6664 3 месяца назад

    Hell ya!!

  • @blmdh20s
    @blmdh20s 3 года назад +3

    Why would you purposely introduce contaminants into the system with the thread seal when attaching the liquid and vapor lines? How long did this unit run until it failed?

    • @mikekellum6238
      @mikekellum6238 3 года назад +4

      It shows the installer has no idea how a flare fitting works. The threads do not prevent leaks. The threads provide the torque to which forces the flare surface to mate with the connection surface. Thread seal is not needed and as you correctly pointed out, contaminates the system.

    • @gazd4812
      @gazd4812 3 года назад

      @@mikekellum6238 does the copper pipe (flare fitting) deform at the point of contact, when its tightened ?

    • @mikekellum6238
      @mikekellum6238 3 года назад +3

      @@gazd4812 No. The flare, when properly made simply mates with the surface of the connection. The threaded nut, simply apples the torque required to keep the flare faces tight against each other. This creates the leak free seal. Threads are NOT used to seal .

    • @Ivebeenaroundyouknow
      @Ivebeenaroundyouknow 3 года назад +1

      I was physically cringing watching him apply sealant, especially over flare tip openings. Otherwise it was a very thoughtful install.

    • @jankensmith7935
      @jankensmith7935 3 года назад

      Nice video. I was a little puzzled by the thread seal as well, but certainly appreciate the video.
      Masks were most likely for fiberglass and dust not a virus....lol

  • @iamdenislara
    @iamdenislara 2 года назад

    14:27 question: those systems don’t require purging. So why did you?

    • @BridgerScientific
      @BridgerScientific Год назад +1

      The system would benefit in longevity from purging with dry nitrogen. And he should also have done a pressure check at ~ 400 psi with dry nitrogen before pulling the vacuum. And as others have said, he should have used a micron gage on the vacuum test to insure good sealing all around. The difference will be, does he get 12 to 15 years out of the system, or less? When the moisture separator/filter is all used up from taking contaminants out of the system, or the refrigerant leaks out to a certain extent, service will be required. He is no doubt saving $ doing it himself, and bonding with his family. So worth the risk I would assume.

  • @Amitsharma-cm1tx
    @Amitsharma-cm1tx 3 года назад

    15×15 ke rom me lgani h sir kini lgegi or kya price h sir

  • @MatthewsFabrication
    @MatthewsFabrication 2 года назад

    Apparently my brand New 36,000btu unit Compressor motherboard is bad???

  • @MysticSephiroth
    @MysticSephiroth 2 года назад

    If I wanted to add refrigerant to the unit, which valve do I use to do? I have a 5 zone

    • @DaveJiu
      @DaveJiu Год назад

      After the installation, I recommand to only add refrigerant while cooling using the gaz line(the bigger one)

  • @JDell-xl7cx
    @JDell-xl7cx 3 года назад +1

    Video- 😃 Music- 😴

  • @caseherc5991
    @caseherc5991 2 года назад +2

    Music is not necessary, it's not a wedding.

  • @Elder650
    @Elder650 3 года назад +1

    Are you sure just 12000 btu or 1 ton is enough for 400+ sq feet area 😳. Is it for cooling also or only for heating? Cuz in India every brand suggested me 4 ton or 2-2 ton 2 units at least for a 500+ sq feet area with 10 feet ceiling ht so I got 2 units of 24000 btu (27K max at powerful mode) so in total I’ve 54000 btu at max for cooling only. Pls reply.

    • @jamess5872
      @jamess5872 3 года назад

      My 2500 sq ft house has 2 2ton units (24000 btu), one for upstairs and one for downstairs. I am not sure of your complete sq ft but 54000 may be overkill.

    • @Elder650
      @Elder650 3 года назад

      @@jamess5872 Do you guys run aircons all the time cuz like if the temp remain low and constant for all the time then even a smaller unit could just maintain. I use them for 10-12 hrs in day time as it’s a living room and there are 2 2 ton units for a 500sq feet living room and it takes almost half an hour to reach at 25°C when outside temp ranging from 35-45°c in my area and these ACs are the best of the market for cooling power. I think you’ll not believe we have 18000 btu or 1.5 ton units in each of 3 bedroom and most people have such configuration here in my county.

    • @jamess5872
      @jamess5872 3 года назад +1

      @@Elder650 I went back to look at my data from last summer, in the month of august in southern US where I live (humid and hot) My upstairs unit ran for 140 hrs when maintaining a temp of 24°C. Temps outside were 36°C, when factoring humidity it's real feel around 40/42. I run my units about 7 months out of the year but I'm not in a climate like you are. It's just amazing you would require so much cooling capacity for a small space, hows the insulation in your house?

    • @Elder650
      @Elder650 3 года назад

      @@jamess5872 it’s a blessing to have climate like your place cuz the utility bill for elec consumption is a huge pain when running almost 100,000 btu ACs. My house is actually a villa type it’s surrounded by medium height trees and it’s a pretty old house but old houses in India actually have better insulation cuz of walls as thick as 18” made up of bricks and concrete and we also have good blinds and curtains to avoid direct sunlight so I would say we’ve above average insulation compared to others here. But the climate is kinda tropical temps could go high like 45-46° easily with humidity above 60% almost whole summer season.

    • @mintheman7
      @mintheman7 3 года назад

      It’s highly dependent on the climate and construction/insulation level of the house. For example, passive standards require a building to use no more than 15kwh/sq meter for heating or cooling per year. You can literally heat the whole house with just a hair dryer

  • @euskadi46
    @euskadi46 3 года назад

    What refrigerant it uses?

    • @BridgerScientific
      @BridgerScientific Год назад

      R410A is most common for Senville units in the USA circa 2022

  • @davidcoleman6995
    @davidcoleman6995 4 года назад +2

    wrong size crows foot on the torque wrench....may provide improper torque.

    • @degenhexican9355
      @degenhexican9355 3 года назад

      Using a crows foot on a torque wrench will give improper torque.

    • @marsluna2127
      @marsluna2127 3 года назад +1

      @@degenhexican9355 You can use a crows foot! The crow foot gives correct torque when it is at 90deg to the torque wrench. Otherwise, one needs to do some calculations based on chosen angle and length of the foot.

  • @MatthewsFabrication
    @MatthewsFabrication 2 года назад

    Mine is installed but won't do anything. Just beeps & lights come on, but louvers won't move or close when turned off.
    Any tips?

    • @BridgerScientific
      @BridgerScientific Год назад

      check the power cable wiring between the outdoor compressor and the indoor wall or ceiling air handler. Communication occurs on these lines and if no comm, no work.

  • @chrisrivera112
    @chrisrivera112 2 года назад

    viddeo put me to sleep in 30 secomds

  • @hdsatsandiego
    @hdsatsandiego 3 года назад

    I felt sleep with the music

  • @DegenerateToo
    @DegenerateToo 2 года назад

    This is why Asians have children, free labor. This how you learn at an early age to use your hands and don’t trust anyones work because you and your family would have done a better job and cheaper too.
    Can I borrow your kids?

  • @davidbohannon14
    @davidbohannon14 2 года назад

    Can he not afford a multi tool

    • @balint133
      @balint133 Год назад

      it makes a big mess, doing it this way takes not too much longer but results in way less dust

  • @kiwangochaneltz6008
    @kiwangochaneltz6008 3 года назад

    Safi

  • @IADHDD
    @IADHDD Год назад

    Your BTU calculation isn't 100% correct. You take the cubic footage of the space X temperature change X 0.133

    • @marcoeis6598
      @marcoeis6598 Год назад

      Can you post an example so I can better understand ? This is the first time I've seen someone use volume which in my opinion is the correct method when dealing with air

    • @marcoeis6598
      @marcoeis6598 Год назад

      I think I figured it out, let me know if I'm wrong. Multiply total volume by temp change. So if it's 30 outside and I want 70 inside that would be 40, is that what you mean ? ...and then multiply that answer by .133 . These numbers seem to make sense

    • @2LegitTooQuit
      @2LegitTooQuit 3 месяца назад

      I’m also interested in his BTU calculation correction. But unfortunately this gentleman hasn’t responded/answered your questions @marcoeis6598

    • @2LegitTooQuit
      @2LegitTooQuit 3 месяца назад

      @@marcoeis6598Ever get an answer?

  • @Amitsharma-cm1tx
    @Amitsharma-cm1tx 3 года назад

    Aapka nmbr btana sir

  • @grumpyg9350
    @grumpyg9350 3 года назад

    🤦‍♂️

  • @automatedcomment
    @automatedcomment Год назад +1

    You made a big boo boo. You need a torque wrench. Also reflare your fittings. Factory fittings never good

  • @caseherc5991
    @caseherc5991 2 года назад +1

    Didn't even get to here in run, thanks for wasting my time 🤦

  • @jamesceltic6011
    @jamesceltic6011 Год назад

    I dont think they should give up their day job

  • @theryanwitski
    @theryanwitski 3 года назад

    Great video! Thanks!