YR1035+ Lithium Battery Internal Resistance Tester,low Z and voltmeter tests,Real four point measure
HTML-код
- Опубликовано: 8 фев 2025
- YR1035+ Real Four-Wire Lithium Battery Internal Resistance Tester,low Z and voltmeter tests and using guide, a very useful instrument for very low Z resistance, step by step guide.Also measuring NiMh, Lead acid and any kind of cells and batteries.Build your own shunts ammeters ,checking cables and their resistance and very low resistance meter like 0.001milliohms!
So how to know what LI ION battery is faulty?
What is value to mili oms that indicates that battery is bad ?
And what is for voltage?
Thx for explaining
P.s i bought it yesterday
Normally a good 18650 li-ion should have around 30 miiliohms (chargerd) about max 50 milliohms can be used for non-power hungry devices (radios)...everything higher then 50 it's gone... Sometimes a cell can be deeply depleted under 1V...very possible to resuscitate it with a proper charge...so final voltage should be 4.1-4.2V. Let it be for few days, eventually measure the voltage. If it's under 3.6V ...it's gone. So, finally , after few days of stand by a good cell (18650 only! ) should have around 30milliohms and min 3.6V. Other kind of cells depend on the capacity and purpose. You should check their own documentation for proper numbers.
This is a good demonstration, thank you very much!😃
Glad it was helpful!
121421/036h PST... Thank you for the demo on how to operate YR1035+ Battery IR analyzer.
Yes, very nice tool!
Thanks Viorel! You helped alot in order to demystify the original instructions of this device. Chapeau! :-)
Glad it was helpful!
Hey! Just give me a hand and subscribe ! Thanks!
Thanks for this video, based on a review of the YR1035, that unit uses a 900mAh 18350 battery internally. So this updated YR1035+ unit now uses an 18650 battery inside -- is the 18650 battery easily replaceable -- do you see a capacity marking on the internal 18650 battery inside the YR1035+ and also how is the battery attached (is the 18650 battery soldered to connectors on the board ?)
I'm interested to find out because I have an older YR1030 unit and I've used it quite often for more than a year now -- its internal battery drains very quickly now. I'm looking at this YR1035+ unit, 18650 battery would likely be easier to replace in case the internal battery has been "spent" (shortened battery life)
The battery is no name, clear 18650, same sizes, it's soldered on the board, so far I charge it once, when it came and still full battery, I don't used it so often..
Hey! Please give me a hand and subscribe! Thanks!
❤️❤️❤️
Thanks!
24:40 Safety instruction in manuel says
„Always pay attention to the correct polarity! Incorrect polarity can irreparably damage the device and the battery. There is a risk of short circuit!“
In real life..never happened ..but I'll be careful for the future..
Bought this device recently and unfortunately, mine is missing calibration option. Do you know maybe the reason? Firmware update or...?
Check the manual..it should be
@@viocaia manual point to the No.7 in the menu, just like yours, but under No.7 and No.8 in the menu are just 3 dashes, like:
"7. ---"
"8. ---"
Guess something is wrong with the software.
@@neshco Sorry but I got no idea how that can be done, probably a resoft? Is it YR1053+?
@@viocaia Yes it is YR1035+ and sw version is 2.2206, that is what is shown at the boot when I turn it on. What version show your device at boot?
@@neshcoLook here ruclips.net/user/shortsu-io4_l3f4c?feature=share
Old video but...how can I power on the ZR? I buy thr YR1035+ right now FW 2.2111 Thank you
To power on? simplypress Power.To recharge, use a Micro USB cable to a 5V phone charger.As for ZR function is auto on when you start the meter
@@viocaia thank you, yes I know how to power on the YR1035 😊 but question was how to “power on ZR?”. Maybe my tester doesn’t have it.
@@Milons What do you mean by ZR..it's already on auto ZR when it's starting...
@@viocaia May be mine doesn't have this function, I saw your tester and it has written on the HOLD button ZR, mine not. I'll ask to YAOREA
@@Milons Maybe...
Great Video, thanks for the Instruction.
Now i understand the YR1035+ before i have it :D.
I was suprized that this Device has good Nichicon Capacitors inside, but maybe these are Fakes?
So far it's working great..
Great video. I bought the same meter, but sadly only Chinese text on display and documentation. There is however also english text on the front so I am hoping there is a possibility to set the language. If so, could you show me the menu flow on how to set to english language from power up of the device, (or point me to an English manual which explains it)
I'll do that next days
Please help with subscribe
Just checked..there is no option about language in menu..maybe there is a way to load a new firmware..I don't know, you should contact the producer.
Found the language setting menu in the last Chinese menu (nr. 9). There was a CNL entry and I managed to change it to ENL (English Language vs. Chinese Language). Now I have a much more understandable and working system using your info.
@@i.verlaek Super ! Good to know!
But how do you charge it?
There is a min USB port for charging with a regular mobile 5V charger.Inside it's 18650 li-ion cell
@@viocaia oops, i had not noticed. Thanks for the reply. I was worrying about this.
Good review. Why is the voltage resolution so low?
I suspect this meter is not genuine because as far as I am aware these are 100000 count. Did you buy it from Yaorea?
I bought by Banggood , I'm not sure if it is a fake or not, all I can say is doing the job...
@@viocaia I spoke to Yaorea "official store" via Aliexpress and they said this is the specification for their meter. YR1035 + accuracy format: ±([accuracy percentage] + [minimum effective bit number]) range maximum resolution accuracy display mode 20mΩ 0.01mΩ 0.7% +7 22.00mΩ (when ZR function is enabled) 200mΩ 0.1mΩ 0.5% +5 220.0 MΩ 2Ω 1mΩ 0.5% +5 37Ω 20Ω 10mΩ 0.5% +5 39Ω 200Ω 0.1Ω 0.6% +5 45Ω gear range from 5% to 95%, when it is not within this range (less than 5% gear range, or greater than 95% gear range), the error may be greater than the above accuracy. Voltage measurement: ±(% reading +% range) range maximum resolution accuracy Display Mode 1V 0.00001V 0.15+0.015 .99999V 10V 0.0001V 0.15+0.010 9.9999V 100V 0.001V 0.15+0.015 99.999V positive and negative symmetry error ±(0.012% +5 words) temperature Drift 100ppm/℃ within normal service temperature (10℃-40℃)
@@thepowersource1602 My mistake, I just checked it was by Aliexpress..www.aliexpress.com/item/4000347233749.html?spm=a2g0s.9042311.0.0.16144c4drMpcBB
@@viocaia I ordered one based on your review except I ordered it from the Yuarea store because the specs say it can display 99999. I hope it's not the Chinese version.
Thanks a lot, I was looking for such video.
Most welcome 😊
Hey! Just give me a hand and subscribe ! Thanks!
How do you change the language? Mine is in Chinese :(
check the settings..see for CC subtitles and should be a list with available translations
@@viocaia you mean in this video? I haven't seen a language setting here.
Sorry! I thought your talking about subtitles! Now I got it..! About changing language now..some YR model are only in chinese..let me search for manual and I'll be back to you..
I could find any language setting under Menu..take a look here also. www.eevblog.com/forum/testgear/eevblog-121gw-discussion-thread/?action=dlattach;attach=415452
@@viocaia I don't think that's the link you intended to share.
Καλημέρα κυριε Caia, σας ευχαριστούμε για το πολύ ωραίο βίντεο που είναι χρησμό για εμας τους αρχάριους, εχω ένα πρόβλημα με το YR1030 έκανα το λάθος και δοκίμασα σε ταση 60 volt ενο απαγορεύετε δια ροπάλου ανω τον 30 volt, απο τοτε οταν το ανοίγω δεν ανάβει και κανει συνέχεια μπιμ,μπιπ,μπιπ... Του αποσύνδεσα την μπαταρία μηπως και διόρθωση αλλα τιποτα, αν μπωρειτε να με βοηθήσετε για να ξαναδουλέψει θα σας ειμαι ευγνώμων σας ευχαριστω εκ προτέρων καλή συνεχεία!
I wish to help you with a magic trick..but I'm afraid it's gone...by the book they say it's 100V max, so it shouldn't be a problem in voltmeter mode to measure 60V, but not in resistance mode..so I think the input chip it's burned or something, there is a short somewhere if the light is not coming one..check the current from the battery..it should e few milliamps..also check all the capacitors for short..
@@viocaia Επανήλθα και πάλη για να ευχαριστήσω για την βοήθεια που όντος δούλεψε αποφορτιζωντας την μπαταρία στα 3,4 βολτ άναψε και πάλη η οθόνη με την διαφορά ότι είναι στα κινέζικα (πριν αγγλικά) πως θα αλλάξω την γλώσσα στα αγγλικά;. Ξέχασα πριν να αναφέρω ότι η βλάβη προέκυψε μετρώντας αντίσταση και όχι βολτ.. και πάλη ευχαριστω!
@@christosxenopanagos2737 my deviceYR1035+ doesn.t have a language menu..so I can't point you to..but try Power/nr8/factory reset/yes
@@christosxenopanagos2737 mayba this can help
www.scribd.com/document/494989671/Yr1030-en-Draft
che peccato non capire l'inglese!!
dimmi solo cosa ti interessa.. Ti tradurrò il testo..
Google RUclips ha anche una funzione di traduzione automatica.. vedi "impostazioni" e cerca la lingua italiana