hand first of all so you are a very clear and very good knowledge of HVAC technician maintenance everything in my life I can't see this type of technician I salute you
Hi sir how are you Air cooled chillier and water cooled chillier how to get problem interest I am to Qatar I watch to video very good training I like to C4 chillier
Sir kuch bhi kaho ap lekin ap ne mere dimag m chiller ghusa diya I hope you will get more subscribe we always support you honestly your voice and teaching style 🔥🔥🔥🔥
Thanks alot for your afford the video was really useful and I would love to know if you could explain how you can test the different sensors and what It gives alarms in the display. 2- how to verify if there is leak in chill and what is the indication is finally best of luck 👏
Bhai ek economizer condenser se aata hua bacha hua vapour gas ko liquid banata h or wo hi economizer bacha hua liquid refrigerant convert krke vapour refrigerat ko compressor Dene ka kaam krta h. ya Phir dono ke liye alag alag economizer laga hua hota
Evaporator ka thoda or details mai btana tha ki ahu mai supply kaise jaata hai or return kaise krta hai or isme pump ka kya role hai shayad 5 min or add krna tha phir bhi bht knowledgeable video hai
Bahoot sukriya dost apka .... Lekin dost jyada long vidio log Kam dekhte hai .....dekho time milega to Mai Apke is topic pe jarur upload kar doonga vidio thank you 👍
parts different 👇 👉in air cooled 1. choti capacity me hoga 2. condenser air cooled fins typ rahega 3. condenser fan use hoga 👉in water cooled 1. badi capacity me hoga 2. cooling tower rahega 3. cooling tower fan rahega 4. condenser water cooled shall and tube milega .....
chiller Ke inlet line me valve ,bellow, pressure gauge, temperature gauge chiller ke out line me 👉 pressure gauge, temperature gauge,water flow switch , on off valve , ahu ke inlet me 👉 valve, pressure gauge, temperature gauge, ahu ki out let me 👉 pressure gauge, temperature gauge, actuter valve , and on off valve..👍
Sir agar hum koi bi chiz ko welding kar yaa badal tu gas ko nikal kar hi welding kiya jata hai ya leakage ho tu bi gas nikal kar hi welding kare gay kya
Agar jaha pe aap velding yani brijing marenge .. waha se gas ka सर्कुलेशन hota hai .. to apko poori gas nikalni padegi to hi aap velding maar sakte hai .. aor agar waha se gas nahi sirculation karti to aap velding maar sakte hai .. 👉lekin behtar ye hai ki aap gas ko nikal ke hi velding maare .. aor agar gas ki लीकेज की जगह pe velding marana to aapko poori gas nikal ke hi velding marni hogi ..
Hello bro good videos hvac thanks bro i need help 30xa alarm locked rotor the a compressor or control one phase fuse followup how to check slide valve working how any videos or carrier30xa alarm video way coming wat do make one videos halp for hvac technician
Pahle chilled line ko poori Tarah se full kar diya jata hai phir yahi water ahu FCU csu se chiller me circulation HOTA rahta hai ...jab bhi Kuch water is line me Kam Hoga use make pump wapas se fill kar deta hai ...aor make up pump water make up tank se leta hai 👍
Ji hamne primeri aor secondri pump dono ke ooper hamne vidio upload kiya hua hai aap dekh sakte hai description me link hai ... Agar aor koi question ho to aap jaruru pooch lena sukriya 👍
that is Symple ... agar Evaporater me heat load kam hai . to apki gas ko liqvid to vaper banne me problem hogi qki waha pe heat nahi mil rahi hai .. to us condition me 👉low superheated ya wet compretion hoga ....
Bhai ye Evaporator jo chillar h usme water initially kahin se toh ata hoga na jisko low pr low temperature liquid refrigerant chill krta h , toh sidha sa sawal ye h ki chillar me initially pani make up tank se ata h kya .?? 🤔🤔🤔🤔🤔
dost ...chiller side me gas ka temperature minus me hota hai ...aor condenser ke ander gas ka temperature 40 digri celcius se 55 digri celcius tak hota hai
Ek aircooled chiller hai Usko 15 chiller water out temp 15c set hai 1 digri setoff hai 14.1 aata hai fir unload hojata hai70percent fir temp bar jata hai cutout nahi hota hai screw compressor 90 tr Problem kya hai isme
Ji ye convert heatsink wo temp. Batata hai jab apka chiller👉 Ac to dc aor phir dc to ac supply me convert hota hai to .. us condintion me Jo temp. Genrate hota hai usi ko convert heatsink temp kahte hai
sir mera nam Suab Ahmed me dubai rehta he. me refrigeration & air condition department se diploma kiya. abe me aisa plant operation ka job dund raha he.
Chiller ka standard inlet aor outlet temp.👉 Inlet 11 to 13 digri celcius Outlet 👉 6.5 to 7 digri celcius Condenser ka inlet 27 to 29 digri celcius Outlet 31 to 35 digri celcius
Ek baar greasing karke check karo .. Agar phir bhi aa rahi hai to supply air duct and return Duct check karo open hai .. aor agar phir bhi aa rahi hai to 🤗 dekho kahi se koi part loos nahi ya phir kahi se air suck to nahi kar raha hai .. aor agar phir bhi aa rahi hai to bhai bearing chenge kardo 🤗
@@c4chiller9984 Sir Example k liye 20TR ka Reciprocating compressor hai toh usme kitni kg Gas dalegi .. Kya koi formula ye measure hai jisse pata lage.. Aur koi question kare to iska answer Kg me batana hoga ya PSI me ya dono
Pahle aap hamesha use psi me batana .. yaad rahe ki har gas ka pressure alag hota hai .. Jaise👉 r410A ka suction pressure 120 psi 👉R134a ka suction pressure 35 to 50 psi .. .. Aor agar waight me pooche to 750 gram to 850 gram par tr ke hisab se gas add hoti hai
ok ji .... gas using R134a and muffler ko aap aise samjh lijiye ...ki jaise gadiyo me cilencer use hota hai usi tarah se ham muffler use karte hai .... 👉 suction and discharge ke time me jo gas circulation ki noise hoti muffler usi noise ko kam karne ke liye use kiya jata hai ... thankyou ..For your comment 👍
Sir hum carrier chiller operating kar raha hu but condenser temp Kom nehi ho raha he ct fan chal raha he pher vi temp. In -33 out -36 ho raha he isliye chiller load sar de raha he . condenser ka pani vi nikala he pher vi temp Kom nehi ho raha he Plzz batao🙏🙏🙏🙏🥲
Sir thoda doubt he water cooled chiller samaj me aa gaya he. Lekin ye jo air cooled chiller h usme chiller me gas thandi kaise hoti h ? Aur aur Isme air cycle lagegi n ?? Kyuki ahu me wo line connect rahegi to ahu me gas circuit hoga ya water ??? Ye thoda bataiye sir ki air cooled Chiller me yani evaporator me kya procedure hoti he.
ji ahu me water hi cerculation karega .. air cooled chiller me bas ye hai ki uska condenser air cooled ka fins typ rahta hai aor condenser fan lage hote hai
@@c4chiller9984 ok sir chiller shell and tube type ka hota h right to shell me gas h aur tube me pani he to wo pani kaha se usko milta h ??aur wo cycle close loop rehti h ya open loop.
Dekho cooler ke pass ek sensor laga hoga .. jaha se water in our out temp. ka sensor hota hai 👉wahi pe ek aor aor sensor hota hai use kholo aor saaf karke phir se wapas lagado .. yaad rahe ki sensor ko lagate time ander 4 pin hoti hai charo pin theek se fix honi chahiye
Sir air cooled chiller maximum kitne ton tk aati 2nd question mera ye h ki solenoid valves waise to pta h bt koi interviewer puchh de tb exactly iska jawab kaise de
Maximum 60 tr ka ek compressor aata hai .. phir uske baad 1 ya 2 compressor lagake usi chiller ko 120 ya 150 tr tak laga sakte hai lekin 👉 compressor 2 ya 3 lagane padenge .. Answer no.2👉 solenoid valve ek electrick valve hai jo supply dene pe open hota hai aor supply off hone pe close ho jata hai ..👉 yani ki jab ham solenoid ko supply denge .. to jo cheej uske ander yani gas ya water cerculation kar rahi hai wo cheej cerculation karti rahegi aor jaise hi supply off hogi vaise hi👉 cerculation bhi band ho jayega ..
600TR water cooled centrifugal type pr ap vedio bnakr explain kiye h , to 600TR sunke mai samajh gya tha ki 600TR ki puri ye machine hogi ya 600TR ka compressor hoga pr aapke jawab se ye clear ho gya ki 600TR ka jo banay the usme v compressor ko connect krke 600TR banaya gya hoga right sir Aapka bhut bhut sukriya sir😊👍
Ji bilkul 👍 Centrifugal compressor sabse high capacity me aate gai hai.. agar koi chiller 200 tr cross hota hai to usme 1 hi centrifugal compressor lagake kaam ho jata hai ... aor agar centrifugal ki jagah koi aor compressor lagega to kam se 4 compressor lagane padenge
3.517 cooling watt = 1 TR HOTA HAI 2.4 GPM = 1 TR HOTA HAI DOST...name plate pe apko GPM ya phir cooling capacity mil jayegi aap asani se nikal sakte ho tr 👉jaise 100 GPM likha hua hai to 100÷2.4 = 41 TR around to apka chiller 41 TR ka hai👉 aise hi aap cooling watt nikal sakte ho jaise 140 kilowatt cooling capacity hai to 140÷3.517= 39.8 tr around 40 TR ka chiller hai .. Abhi bhi koi doubt ho to pooch Lena dost 👍
1st option.. display pe error dikhayega ..jaise ki chiller temp.sensor kharab hai to .👉. chiller temp.sensor error aise aa sakta hai display pe alarm .. 2nd option Jab aap apni logbook me chiller ki reading likhte hai to .. apko usme bhi every hour dhyan dena hoga ki saare sensor ache se kaam kar rahe hai ki nahi....
Bhai ka bol rehahi ho ...superheated bole to ka hai bhai?? Video achha banate ho but wrong terms use mat karo bro.. Superheated term ko janne ke liya thermodynamic study karna padega bro😂
@@c4chiller9984 sir m n mechanical engineering se B.tech kia h m n MES m (military engineering services ) m contact basis pr package AC m job ki but muje Chiller m scope chahiye uske liye koi plateform hi nhi mila ....sir training Kara dijiye jisse m HVAC department m ek acchi job le saku🙏
Bahoot sukriya ji apka... 💐 Bahoot se train ladke hai isi channel pe agar unke liye koi vacancy ho to ap unhe details de sakte hai .. jabki bahoot se B.tech bhai bhi hai ... Thank you 👍
Aap ko awaz masahallah buhat achi hai ❤ + teching bhi masahallah buhat zabadadt hai ...jazak allah
❤❤❤bhai .....🎉🎉🎉 aap khuda salamat rakhe....amin
bahoot sukriya dost ...apki duao ke liye 👍⭐
Really vry useful for HVAC field thnx
आपकी व्हिडिओ knowledge wali रहती hain bahut kaam aati hain keep it up love from Maharashtra Marathi manus🙏🙌
thank you for supporting 🤗
Masah Allah sir apka vidio bhoot bhoot acha hota hai app samghate bhoot acha hai 🤗🤗🤗 thanks sir ji
Jii bahoot sukriya 👍
hand first of all so you are a very clear and very good knowledge of HVAC technician maintenance everything in my life I can't see this type of technician I salute you
Bahoot sukriya apka ✨
Aap ka naam kaya boss
Can u snd your no
sir plz kha sihku hvac technician kam
aap bta skte hai plz sir btye
Very nice explain and very clearly of all parts and components , and their function brother ,
Jazak allah khair❤
bahoot Sukriya
Very nice 👍
👍
Aap bahot achhe se samjhate ho
Ji Bahoot sukriya..
You are first viewer 👍🤗
Good job sir
THX sir for new video shereing.
I request please make new video HRV system.
Aapki video bahut useful hoti hai
bahoot sukriya ji apka
Nice
Bahot khub bhai
Hi sir how are you Air cooled chillier and water cooled chillier how to get problem interest I am to Qatar I watch to video very good training I like to C4 chillier
Question kya hai apka ??
Thank you so much bro.
Sir kuch bhi kaho ap lekin ap ne mere dimag m chiller ghusa diya I hope you will get more subscribe we always support you honestly your voice and teaching style 🔥🔥🔥🔥
bahoot sukriya ji apka ....🤗
Mind blowing ❤❤ sir
thank You jii 👍👍
too much useful video
Bawal sir ji good job
Bawaal 🤪🤪
Thanks alot for your afford the video was really useful and I would love to know if you could explain how you can test the different sensors and what It gives alarms in the display.
2- how to verify if there is leak in chill and what is the indication is finally best of luck 👏
Very nice
Bhai ek economizer condenser se aata hua bacha hua vapour gas ko liquid banata h or wo hi economizer bacha hua liquid refrigerant convert krke vapour refrigerat ko compressor Dene ka kaam krta h.
ya Phir dono ke liye alag alag economizer laga hua hota
Good my friend 🇦🇪
Thank you 🤗👍
Bhai agar mary pass ikhtiyar hota to main apki har video pe hazar like kr daita sach me ap bahot nice technician hain
Ji bahoot sukriya apka ✨
Bas ap logo ki duay🤲 hi kaafi hai hamare liye
👌🙏🇮🇳🙏👌💐💐💐💐thanks Bhai😇😎Dil se 💕 bahut bahut shukriya aapka💐👌🙏
Apka bhi sukriya ji 🤗✨
🎉 chalu Kiya jata hai kaise air cooled chiller video banakar
Shell and tube leakage repair ko video banaya ni sir ji
Ji bana denge jaldi 👍
Evaporator ka thoda or details mai btana tha ki ahu mai supply kaise jaata hai or return kaise krta hai or isme pump ka kya role hai shayad 5 min or add krna tha phir bhi bht knowledgeable video hai
Bahoot sukriya dost apka ....
Lekin dost jyada long vidio log Kam dekhte hai .....dekho time milega to Mai Apke is topic pe jarur upload kar doonga vidio thank you 👍
@@c4chiller9984 thanks sir jiii aap ki baat se sehmat hoon wo ahu ke topic se related ho jaata hai
Jii sahi kaha Apne ... topic change ho jata hai 👍
Love you sir keep on🙏🙏🙏🙏
Ji jarur 🤗
Bhai economizer or iske sensor ke baare me full video bano yrr
dost economizer ki vidio upload kiya hua hai description me link hai aap dekh sakte hai...baki kuch questions ho to aap pooch sakte hai 👍
Bhai air cooled and water cooled ke different ke bare me batao full explain kr ke
parts different 👇
👉in air cooled
1. choti capacity me hoga
2. condenser air cooled fins typ rahega
3. condenser fan use hoga
👉in water cooled
1. badi capacity me hoga
2. cooling tower rahega
3. cooling tower fan rahega
4. condenser water cooled shall and tube milega .....
Bhai Yourk air cool chiller hi Bhai cooling paid ke glash me Pani nahi dekha raha hai Kya Dekkat ho gi please reply ker do
Sir Air cooled chiller के रीडिंग के बारे me bataiye plz
Economizer ,High pressure switch & low pressure switch kaise kaam krta h or kitne par set rehta h
❤️❤️🌹🌹🌹🌹❤️❤️
Vaiya chiller say in or out line pay ahu ta kiya kiya laga rahata hai acchha say ek video banaiya na plz
chiller Ke inlet line me valve ,bellow, pressure gauge, temperature gauge
chiller ke out line me 👉 pressure gauge, temperature gauge,water flow switch , on off valve ,
ahu ke inlet me 👉 valve, pressure gauge, temperature gauge,
ahu ki out let me 👉 pressure gauge, temperature gauge, actuter valve , and on off valve..👍
Sir Air cooled chiller me cooling tower nahi hota hai to phir water kaha se aata hai
Sir working of chillers ke bare me bataye
dost hamne water cooled chiller ka principal bataya hai .. description me link hai aap dekh sakte hai..baki kuch questions ho to aap pooch sakte hai
Sir agar hum koi bi chiz ko welding kar yaa badal tu gas ko nikal kar hi welding kiya jata hai ya leakage ho tu bi gas nikal kar hi welding kare gay kya
Agar jaha pe aap velding yani brijing marenge .. waha se gas ka सर्कुलेशन hota hai .. to apko poori gas nikalni padegi to hi aap velding maar sakte hai .. aor agar waha se gas nahi sirculation karti to aap velding maar sakte hai .. 👉lekin behtar ye hai ki aap gas ko nikal ke hi velding maare .. aor agar gas ki लीकेज की जगह pe velding marana to aapko poori gas nikal ke hi velding marni hogi ..
sir mujhko hvac chiller techn sikhna plz guide
Apke pass iti hai ya diploma ?
Sir water coled refrigeration cycle ka video hai apke channel pe jissse samajh sake air cold and water cold cycle kya kya laga hota hai and woking
ji ha .... upload hai .. description me link hai aap dekh sakte hai Sukriya
Hello bro good videos hvac thanks bro i need help 30xa alarm locked rotor the a compressor or control one phase fuse followup how to check slide valve working how any videos or carrier30xa alarm video way coming wat do make one videos halp for hvac technician
Ji time milte hi ham apke topic le vidio bana denge sukriya
@@c4chiller9984 thanks pro
Confuse ye hun k kiya isme v pipe me pani k jariye thanda hota hai water chiller ki trah
ji ha ..gas pahle pani ko thanda karti hai ...aor phir wahi thanda pani ...ahu FCU ya CSU me jata hai cooling ke liye 👍
Very nice 👍👏😊😊👍👍
👍👍
@@c4chiller9984 Sar air could Chillar Mein water kahan se Aata Hai
Pahle chilled line ko poori Tarah se full kar diya jata hai phir yahi water ahu FCU csu se chiller me circulation HOTA rahta hai ...jab bhi Kuch water is line me Kam Hoga use make pump wapas se fill kar deta hai ...aor make up pump water make up tank se leta hai 👍
@@c4chiller9984 Thank you❤
Sir ye chiller mean water ko cool karta he ? Aur fir o water AHU me jata he aur vaha air ko cool karta he duct me
bilkul sahi ...ji 👍
hvac technician kaha sikhu aap btate plz 🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏
Sir aapka video se bahut sab kux axa se samjhme jata hai lekin mujhe primary pump and secondery pump ka kya kam hota hai usle bare me batae sir please
Ji hamne primeri aor secondri pump dono ke ooper hamne vidio upload kiya hua hai aap dekh sakte hai description me link hai ... Agar aor koi question ho to aap jaruru pooch lena sukriya 👍
@@c4chiller9984 thankyou so much sir jarur sir
Sir g pls explain ketein k why is high and low superheat (reason tell us)
that is Symple ...
agar Evaporater me heat load kam hai . to apki gas ko liqvid to vaper banne me problem hogi qki waha pe heat nahi mil rahi hai .. to us condition me 👉low superheated ya wet compretion hoga ....
Sir scro chiilar me kitna pc compressor hota hai
kitne ton ka hai ! ye question hai apka??
Bhai please ek bat batye ki dx unit me kyun sa compresor laga hota he our kitne tan ka please reply mi
scroll typ ya phir reciprocating typ
Thanks so much sir
Gas konsa use hota hai chiiler me
dost ...is chiller me R134a gas use ki gai hai ..baki koi koi chiller me r22 ya r410A bhi milegi 👍
Sir kya sabhi Air cooled chiller ke evaporater ke shell side me hi refigrent hota hai
Nahi ... Kisi kisi me hi hota hai..
Kahi kahi pe apko shell me water milega
@@c4chiller9984 Thank you so much for reply sir,,
Isme ahu ,fcu jyda kya use hota hai
maixmum Ahu use hota hai ..
but ...
FCU
CSU ..bhi kiye jate hai ..jaise jaha required hoti hai
Bhai ye Evaporator jo chillar h usme water initially kahin se toh ata hoga na jisko low pr low temperature liquid refrigerant chill krta h , toh sidha sa sawal ye h ki chillar me initially pani make up tank se ata h kya .?? 🤔🤔🤔🤔🤔
Yes make pump se aata hai
Achha video bani hai aapne
thank you 🤗
Se confirm kar sakte hain ki yah kitne tan ka compresser maloom Hoga aur kaise pata chalega return ka compresser hi
Return ka compressor mtlb ????
Question clear kariye aap
Sir LP and HP issue pe ek video bana dijiye jisme uska Reason aur solution dono ho
Ji jarur
time milte hi ham jarur upload kar denge sukriya
@@c4chiller9984 Thank you sir
Sir kitna degree rahta hai chiilar ke undar gas
dost ...chiller side me gas ka temperature minus me hota hai ...aor condenser ke ander gas ka temperature 40 digri celcius se 55 digri celcius tak hota hai
Sir mujhe ac se trade ki
Bhai TFA kya hai ispe kuch video bnay
Ji hamne apke pichle comments me answer diya hua hai
Ji ye hamne pahle baar comment Kiya hu or Mai isse pahle TFA ke bare me comment nahi kiya aapke pass SIR
Treatment fresh air
Accuator konsi line mai use kerte h aur q
Ahu ke returns line me ..
Temp. controller ki tarah use kiya jata hai
System ko Handel karne ke topic pe questions karenge wo log .. baki apka knowledge main hai
Ye konsa type h chiller ka
air cooled typ ka
All over the world, working same hoti h kya sir ?
Yes
Air cooled chiller par banae
dost ye air cooled hi hai 👍
And if we have mother bord faults how to verify it
There are multiple functions in microboard that's depends on which function not working ..
Ek aircooled chiller hai
Usko 15 chiller water out temp 15c set hai 1 digri setoff hai 14.1 aata hai fir unload hojata hai70percent fir temp bar jata hai cutout nahi hota hai screw compressor 90 tr
Problem kya hai isme
gas ki suction pressure aor discharge pressure dono check karo
@@c4chiller9984 134 gas hai aur 69percent par 33 psi hai
Sir ye vsd high converter heatsink temperature Kiya hota h vsd ka to hota h per ye heatsink temperature Kiya h plz ans
Ji ye convert heatsink wo temp. Batata hai jab apka chiller👉 Ac to dc aor phir dc to ac supply me convert hota hai to .. us condintion me Jo temp. Genrate hota hai usi ko convert heatsink temp kahte hai
@@c4chiller9984 thank u so much sir bht Kuch sekha h apse poch poch kr
@@c4chiller9984 sir ye brhta kb h koi iske khas reason
Load badhega to .. wo bhi badh sakta hai .. nahi to jo chiller ka electrical panal hota hai . Usme heating jyada ho jayegi to
sir ye kitne tan me h
120
Sir aap ye btao
Chiller 2 type ka hai
Ye aapka air cooled chiller and 2nd water cooled chiller
ji ha mostly.2 typ hi use hota hai ..
air cooled typ
water cooled
Sir watar cold chillar me ketne type ke compressor use krtehy?
Our Air cold chillar me bhi ketne type ke compressor use krte hy ptaey please sir?
Sir ji economizer kya h kahan use hota h iska kaam kya g
Ji is topic pe jaldi hi vidio upload kar denge sukriya
@@c4chiller9984 sukriya bhai jaan reply Dene ke liye aapka videos sabse best aur aasani se samajh me aata h I m from India love you bro
Apki economizer ki vidio upload kar diya hai aap dekh sakte hai ... Link description me hai sukriya
sir mera nam Suab Ahmed
me dubai rehta he.
me refrigeration & air condition department se diploma kiya.
abe me aisa plant operation ka job dund raha he.
Aap dubai me job kar rahe hai ya phir rah rahe hai only ??
Sir chiller ka in and out and condenser pum ka in and out temprature bataye please sir
Chiller ka standard inlet aor outlet temp.👉 Inlet 11 to 13 digri celcius
Outlet 👉 6.5 to 7 digri celcius
Condenser ka inlet 27 to 29 digri celcius
Outlet 31 to 35 digri celcius
Thanks sir
sir ahu ke motar or blowar ke berring or ahu me aavaj aati he uska problam keshe dur kare
Ek baar greasing karke check karo ..
Agar phir bhi aa rahi hai to supply air duct and return Duct check karo open hai .. aor agar phir bhi aa rahi hai to 🤗 dekho kahi se koi part loos nahi ya phir kahi se air suck to nahi kar raha hai .. aor agar phir bhi aa rahi hai to bhai bearing chenge kardo 🤗
THANKS SIR
SIR AAP KA NAME KIYA HE
how to check compressor tanage of HVAC
Chcek the .. cooling capacity
Jaise ki 3.5 = 1 ton
HVAC compresser 3pase
Sir chiller compressor me kitni Gas dalti hai jaise single reciprocating compressor me
Wo TR ke hisab se gas padti hai jitne tr ka apka chiller hai usi hisab se gas padegi
@@c4chiller9984 Sir Example k liye 20TR ka Reciprocating compressor hai toh usme kitni kg Gas dalegi ..
Kya koi formula ye measure hai jisse pata lage..
Aur koi question kare to iska answer Kg me batana hoga ya PSI me ya dono
Pahle aap hamesha use psi me batana .. yaad rahe ki har gas ka pressure alag hota hai ..
Jaise👉 r410A ka suction pressure 120 psi 👉R134a ka suction pressure 35 to 50 psi ..
..
Aor agar waight me pooche to 750 gram to 850 gram par tr ke hisab se gas add hoti hai
@@c4chiller9984 Thank you sir provide me correct information
Gas ke pressure ke topic pe hamne vidio upload kiya hua hai description me link hai aap dekh sakte hai sukriya
You don't share about moflar,why used in this chiller and which type of gas used in chiller ,there r many basic things
ok ji ....
gas using R134a
and muffler ko aap aise samjh lijiye ...ki jaise gadiyo me cilencer use hota hai usi tarah se ham muffler use karte hai .... 👉 suction and discharge ke time me jo gas circulation ki noise hoti muffler usi noise ko kam karne ke liye use kiya jata hai ... thankyou ..For your comment 👍
Sir packej unit. Koto theke koto tr hota ha
dost ...kya poocha apne ??
@@c4chiller9984package unit sir minimum to maximise Kitna hota ha.
Sir hum carrier chiller operating kar raha hu but condenser temp Kom nehi ho raha he ct fan chal raha he pher vi temp. In -33 out -36 ho raha he isliye chiller load sar de raha he . condenser ka pani vi nikala he pher vi temp Kom nehi ho raha he Plzz batao🙏🙏🙏🙏🥲
Check the condenser coil condition
compressor loader and loader continue working then after 2 minutes work on this off on off what is the reason
Chcek the pressure LP and HP first
Sir thoda doubt he water cooled chiller samaj me aa gaya he. Lekin ye jo air cooled chiller h usme chiller me gas thandi kaise hoti h ? Aur aur Isme air cycle lagegi n ?? Kyuki ahu me wo line connect rahegi to ahu me gas circuit hoga ya water ??? Ye thoda bataiye sir ki air cooled Chiller me yani evaporator me kya procedure hoti he.
ji ahu me water hi cerculation karega ..
air cooled chiller me bas ye hai ki uska condenser air cooled ka fins typ rahta hai aor condenser fan lage hote hai
@@c4chiller9984 ok sir chiller shell and tube type ka hota h right to shell me gas h aur tube me pani he to wo pani kaha se usko milta h ??aur wo cycle close loop rehti h ya open loop.
close loop .. wo water ahu se chiller me cycle karta rahta hai ... aor jab kabhi water kam hota hai to👉 make up se water fill kar diya jata hai 👍
@@c4chiller9984 yes exactly now understood. Thank you so much yahi doubt tha clear ho gaya. Close loop rhti h cycle. 👍
👍👍
Carrier 30XA Cooler flow switch set point configuration failure Ka alarm aa Raha hai kya Karu please help me
Dekho cooler ke pass ek sensor laga hoga .. jaha se water in our out temp. ka sensor hota hai 👉wahi pe ek aor aor sensor hota hai use kholo aor saaf karke phir se wapas lagado .. yaad rahe ki sensor ko lagate time ander 4 pin hoti hai charo pin theek se fix honi chahiye
What is super heat Sir
jo gas evaporater ke ander liqvid se vaper bankar Compressor ke ander us condition ko ham super heated gas bolte hai 👍
Thanks sir and your all videos become helpful
Sir air cooled chiller maximum kitne ton tk aati
2nd question mera ye h ki solenoid valves waise to pta h bt koi interviewer puchh de tb exactly iska jawab kaise de
Maximum 60 tr ka ek compressor aata hai .. phir uske baad 1 ya 2 compressor lagake usi chiller ko 120 ya 150 tr tak laga sakte hai lekin 👉 compressor 2 ya 3 lagane padenge ..
Answer no.2👉 solenoid valve ek electrick valve hai jo supply dene pe open hota hai aor supply off hone pe close ho jata hai ..👉 yani ki jab ham solenoid ko supply denge .. to jo cheej uske ander yani gas ya water cerculation kar rahi hai wo cheej cerculation karti rahegi aor jaise hi supply off hogi vaise hi👉 cerculation bhi band ho jayega ..
600TR water cooled centrifugal type pr ap vedio bnakr explain kiye h , to 600TR sunke mai samajh gya tha ki 600TR ki puri ye machine hogi ya 600TR ka compressor hoga pr aapke jawab se ye clear ho gya ki 600TR ka jo banay the usme v compressor ko connect krke 600TR banaya gya hoga right sir
Aapka bhut bhut sukriya sir😊👍
Ji bilkul 👍
Centrifugal compressor sabse high capacity me aate gai hai.. agar koi chiller 200 tr cross hota hai to usme 1 hi centrifugal compressor lagake kaam ho jata hai ... aor agar centrifugal ki jagah koi aor compressor lagega to kam se 4 compressor lagane padenge
@@c4chiller9984 bhut bhut bhut shukriya sir
Chiller kitne ton Ka kaise malum kare
3.517 cooling watt = 1 TR HOTA HAI
2.4 GPM = 1 TR HOTA HAI
DOST...name plate pe apko GPM ya phir cooling capacity mil jayegi aap asani se nikal sakte ho tr 👉jaise 100 GPM likha hua hai to 100÷2.4 = 41 TR around to apka chiller 41 TR ka hai👉 aise hi aap cooling watt nikal sakte ho jaise 140 kilowatt cooling capacity hai to 140÷3.517= 39.8 tr around 40 TR ka chiller hai ..
Abhi bhi koi doubt ho to pooch Lena dost 👍
@@c4chiller9984 thank you so much bro
Bhai main colour blind hu kya me ye work kar kar sakta hu
Kitne colour aap pahchante ho .?
@@c4chiller9984 red green yellow me problem hai
सेंसर खराब है कि सही है कैसे पता चलेगा
1st option.. display pe error dikhayega ..jaise ki chiller temp.sensor kharab hai to .👉. chiller temp.sensor error aise aa sakta hai display pe alarm ..
2nd option
Jab aap apni logbook me chiller ki reading likhte hai to .. apko usme bhi every hour dhyan dena hoga ki saare sensor ache se kaam kar rahe hai ki nahi....
Bhai ka bol rehahi ho ...superheated bole to ka hai bhai?? Video achha banate ho but wrong terms use mat karo bro.. Superheated term ko janne ke liya thermodynamic study karna padega bro😂
dost ....aap bata sakte hai kaha pe mistake hui hai ...mai next time correct karlu use
Sir muje training krni h kya aap kara skte hn HVAC department m
Kya janna hai apko ?? Hvac me
@@c4chiller9984 sir m n mechanical engineering se B.tech kia h m n MES m (military engineering services ) m contact basis pr package AC m job ki but muje Chiller m scope chahiye uske liye koi plateform hi nhi mila ....sir training Kara dijiye jisse m HVAC department m ek acchi job le saku🙏
Ok ji jarur
Ye mera instagram id hai aap yaha pe massage kijiye id 👉 kgufran195
@@c4chiller9984 m n apko Instagram pr message kr dia h aap active ho to plz seen krle
ap kidrose UAE, one job he, ac, manteneg work, duc, splet, cilar, nambar give
Bahoot sukriya ji apka... 💐
Bahoot se train ladke hai isi channel pe agar unke liye koi vacancy ho to ap unhe details de sakte hai .. jabki bahoot se B.tech bhai bhi hai ... Thank you 👍
Thida ache se nhi smjhaya apne khud confuse ho tum
dost kya samjh me ni aaya apko ?
aap batay mai batata hu phir ?
Hi sir please share me number some.doubts
dost ...ye mera Instagram id hai aap yaha pe doubts and questions clear kar sakte hai ..id 👉 kgufran195
Sir ji apka number de dijiye pls
Ji ye mera Instagram id hai ..
Apka jo bhi question hai aap yaha poch sakte hai id 👉 kgufran195
Really vry useful for HVAC field thnx
Nice