Why CT Secondary is always closed | Why CT secondary is never kept open| Hindi
HTML-код
- Опубликовано: 20 окт 2024
- Queries solved:
1. What is current Transformer.
2. Why CT secondary is always closed.
3. Why CT secondary is never kept open.
4. Current Transformer accidents.
5. Current Transformer working.
Hello Friends, in this video we discussed about why CT secondary is always closed in the simplest way possible.
About Channel:
In this Channel we cover the topics like Machines, Power System and General Electrical in the simplest way possible.
#CT
#Working
Kindly subscribe.
Thank you..
Akk Number ❤️🔥 From 7 years of studying electrical engineering 3 diploma aane 4 degree no one will explain me these that u did in just 5 minute maza aa gayaa🥳
After your diploma...Did you get any job after doing diploma?...es Kalyug me sir 😂😂....
Kaha se degree kiya tha?
Bahi ap ko kya smaj aia,mujy b smja dain
Beautifully explained.
Crystal clear Concept ❤️❤️
Wow very Nice explanation sir maja aaya dekh ke turant mind me aa gya 😊❤. Thank you so much sir 😊
Bundle of Thankx sir. You Give Better Information CT.Your Explain Method good.
Thank you Tariq..
Aapke dwara di gyi jankari ek dam satik hoti hai. Khas kar un logo ke liye jo electrical field me job kar rahe hai.
Wow what a way to explain... really appreciating I have visited 1st time on your chanel sir and did subscribe...1st time got the chanel on RUclips that is really appreciable. Please make all possible interview related video on VCB . Thankyou sir ji
Thank you so much Chandan..🙏
Also watch playlist for videos related to Drawing, Calculation, Motor, Transformer, Power Factor Correction and many more..
@@electricalwithabhishekjoshi sure sir ji, make interview related videos on ACB and VCB. I have seen making and breking capacity of circuit breaker... nice explanation.
Okay Chandan.. watch switchgear and protection playlist. Mostly the topics that I choose is itself a interview question.
Yes sir sefety point of view say bhot jaruri ek choti se galti jaan lay sakti hai
Yes.
Love ❤️ you sir. Most respect for you. From Pakistan 🇵🇰
You are absolutely perfact. Please brother try to explain with drawings or pic. That will give more helpful. This is only request.
Thank you...
Okay will add pics for better understanding..👍
Transformer ki winding mein flux produce hotai ya winding mein .pl clarify
You are best explain about electrical
Thank you so much Alok..👍
Secondry side me 3 core hai usme 2 core coonnected , balance 1 core ps class open rakhna chahiye ya short karna chahiye.
The way of explanation is excellent.
Thank you Haroon..
Excellent and such an amazing vedio for understanding!
Ye protection CT me hota hai ki measuring CT me ki dono me
Sir Low tension connection me bhi blast hota he kya ? V 450 or 550 open C T karnese
Kya yah same condition power transformer mein bhi lagu hoti hai
Also kindly make a video on procedure of isolating CT secondary using CT shorting blocks
Highly impressive video. Thanks a lot.
Hello sir,
Kya hum CT ki protection core ko metering k liye use kr skte h Or metering core ko protection k liye, agr nhi kr skte to kyo nhi kr skte plz explain sir
Swithyard par video baniye sir usme use hone wale sare equipment ka bhi
Sir,V.F.D. duty motor ki size jyada kyu hoti hai as compared to normal duty motor for same rating.
Sir isspe bhi ek video banaiye.
Transformer ki secondary bhi close karni hoti he kya sir,agar primary energized hogi to???
Very Good and essential Explaination.
Thank u sir 🙏 for this excellent video...
Most welcome KK..
Sir current transformer ke live tank or dead tank me kya difference hai please explain sir
Thnku sir for sharing this topic...
Most welcome Samvedna..
Sir hmary paas 3,3 year say ct open condition main lagi hoi hain,aur primary main say hmaisha 250, 300 ampair guzrty hain,wo blast nai hoti,kya waja ha
You are great sir ji
Good explanation sir
Thank you...
Best knowledge for me Sir
Sir aapne phle to bola current 0 hojayega fir aapne bola secondry side high current flow hoga yea kese
If CT primary is energised but no current in primary then can we keep secondry open
Please make a video on, how decide relay setting and fuse rating related to motor rating
Arman, I have made video on relay rating and fuse rating.
Watch Drawing and Calculation playlist.
You will get all the video .
Sir A ct HT me blast hota hai kya LT line me hota hai our CT secondary open hone k chances kab rahate hai
Very good sir
Sir,why ct connection done in star or delta connection. What is advantage of this type connection
Thank you sir plz sir insulated bearing pr 1 video bna dien
Very very good
Abhishek Ji if possible can you please make video on generator protection
Specifically pole slip, negative phase sequence,loss of excitation
Okay Atul..
Also watch playlist for videos related to Drawing,Calculation, Motor, Transformer, Power Factor Correction and many more..
Sir,star delta starter ki case me star to delta changeover hote time motor suddenly high peak current kyu draw karti hai.
Shahbaj, ispe ek video banaenge....
Lekin sir kab,mai ye sawal aapse pahele bhi pooch chuka hu.
Great work sir
Excellent explain 👍
Sir what is multiplication factor in Energy meter it will be related to CT PT ratio...plz to video on that....
Very good explanation
Beautiful explanation sir
I specialy request you sir if you give an easy example in any questions I think we should better understand
DCS se motor kaise start -stop karate hai pls sir make video
With DCS interlocking logics..
I have seen one secondary terminal (S1) of CBCT kept open, on asking it was found not in line. Module was in running condition. My question how it is safe and different from CT
Very good explanation👍👍
Excellent explanation sir
Sir really very nice video please make this video with diagram
Thank you Faisal..
Good one ..All the best for your future 👍👍
Sir PT per secondary winding open kerna par short circuit kiu nahi hota ha please ak video banaya
Is this concept applied only to CT or any transformer .If no Y it's not applicable in differ from transformer
Excellent sir
Ct ka connection kese kiya jatahai espe ek vdo banadijiy
Abhishek, if CT sec contacts are connected to relay panel load then even in this case CT sec contacts are to be internally shorted ?
Nice explaination sir
Great explanation
Please explain why required CT Earthing.
I can watch your videos non-stop
Thank you Harshal...
@@electricalwithabhishekjoshi your welcome sir, keep making such videos. And please accept my LinkedIn connection😝
CT ka knee point voltage bhi share Krna sir ji
Abhishek joshi ji... ct secondary ko close kaise karenge....... through drawing yaan phir live practical bataayen
Agar live nahi bataa sake toh drawing banaa kar bataana ki kya aur kaise karna hai
Okay Pardeep...
Also watch playlist for videos related to Drawing, Calculation, Motor, Transformer, Power Factor Correction and many more..
Sir cbr fault kya hota hai
Multiplying facter per video banaye sir
Sir PT ki secodary open honey per kyo ballast nahi hoti
Great explain
Sir
Please Help
Our 3 Phase 15 KVA GENERATOR's one CT (Y PHASE CT) is totally damage.Can we use the Generator Without this Y CT ??
Please Reply
Shandar. Bhaiya❤❤❤❤❤❤❤❤😊
Definitely i learn i red but can't understand well. But today easily
very good sir.
Sir ek bar grid system bare me explain kijiye...
Okay Pranav..
Excellent sir.
Sir plc or drive ka control diagram ek bar bata dijiye..means drive ko kaise ht motor se connection karte hain
Okay Pranav..
Nice .explanation
Thank you Shilwant..
Also watch playlist for videos related to Drawing, Calculation, Motor, Transformer, Power Factor Correction and many more..
@@electricalwithabhishekjoshi Yaa I have watched almost all video.plz upload one video on MV drive .if possible
How mmf is produced in secondary winding of ct
How to short TTB( test terminal block) of ct please make video on it.
Transformer ka 2nd yeary open hone se transformers blast hosakta he kya ?
Agar CT ka primary energize hai and secondary open ho jaye to ho jaega..
@@electricalwithabhishekjoshi sorry sir
Me transformer ke bare me putch rahahu
Transformer ka secondary open hone pe kuch nahi hoga.
UAT
CT and UAT
Like as same principle
Why?
Why this effect is not available for PT or other transformers
Sir Ek video LRS system per bnao
Good explain boss
Excellent
Shandaar sir
Sir plz CTR naitrozen injection system ke bare me video शेयर कीजिए न
Tx.. For excellent videos
Sir kitne voltage pe ye dangerous hota he
Prashanta it's not on some specific voltage. Secondary side ka voltage itna jyada increase ho jaega that cause fatal accident ..
Thanks sir for excellent vedio
Most welcome Mohit..
Good morning sir..
Sir aapke company mei koi vacancy hai kiya diploma in electrical ka.
Please sir aap reply dena
Sir very nice explain.sir please say why ct secondary are earth
really nyc vidoes sir
Sir if mmf produced in secondary is zero how does a ct produce flux
Saikumar, CT will produce flux as CT primary is energized.
Thank you sir for this ✨💫
Why there is carbon dioxide spot in body of CT ?
Nicely explained
Good explanation
Thank u sirji
I need your advise , in an industry due to huge welding machines (inductive load) there is voltage fluctuation due to which solar inverter has synchronizing issues , please suggest how can we avoid this voltage fluctuation ?
u can install suitable capacitor bank to meet the inductive demand locally
@@chapsytapsy its transient voltage that is switching itself in seconds, capacitor banks actually didn't have any impact on transient voltage fluctuation.
@@fahadmukhtar1124 is the inverter also connected to battery. Battery can help supply transient currents and let the system ride through this situation. Otherwise, inverter alone cannot handle this
Sir nice explain 🙏
Thank you...
Nice explanations. Thanks.
Thank you sir❤