Fire Alarm Training Video for the Notifier NFS2-3030 with DVC

Поделиться
HTML-код
  • Опубликовано: 22 авг 2024
  • This is a simple training demonstration of the Notifier NFS2-3030 with DVC. I basically walk the customer through the main functions of the system along with the different types of signals and how to respond to each one. No fire alarm activation in this video, just informational.

Комментарии • 69

  • @aspenqwerty3
    @aspenqwerty3 5 лет назад +1

    Regardless if it's a false alarm, building must be evacuated either or... every alarm should be placed as a serious emergency...

    • @djjammindave
      @djjammindave 5 лет назад +1

      Correct. Unless if it is a drill or posted notice. Testing a building today a kid was just about to ran out of the building in PJ's and gym shoes on hand. I told him "this is just a test", the kid started crying. He asked? what should I do? I said, this is only a test of the fire alarm system, just go back to your apartment. Sad, but true.

  • @jamesdemerin
    @jamesdemerin 6 лет назад +1

    This is the Westin SFO Airport Hotel!

  • @jayja45
    @jayja45 8 лет назад +3

    Only three manual pull stations in a building with 7 floors? In the UK a manual call point (our equivalent to a manual pull station) is required at every entrance to a staircase, and at every final exit. Additionally, a person should not have to travel more than 45 meters to reach a manual call point (25 meters if the person who will be operating the manual call point is likely to be disabled, or if rapid fire development is likely).

    • @TheJFOLKES
      @TheJFOLKES 7 лет назад

      Same here in canada, any exit of a fire zone. there should be minimum 14 pulls in that place. Assuming two staircases.

    • @SamMcWhannel
      @SamMcWhannel 6 лет назад +1

      I believe he meant there's only 3 that will trigger a full evacuation of all floors. The rest will only evacuate the closest 3 floors.

    • @reddyprahlad
      @reddyprahlad 6 лет назад

      jayja45 same in India. MCPs, hooters, speakers, talk back points on the exit ways of the floor.

    • @RobertAslinMusic
      @RobertAslinMusic 6 лет назад +1

      In the US, if a building is fully sprinklered, you actually don't need a pull station at all.

    • @akhilvishnuchippanchira6978
      @akhilvishnuchippanchira6978 6 лет назад

      Hello... Anybody know about incorrectposition trouble in honeywell xls3000 ,

  • @onesyde326
    @onesyde326 2 года назад

    I'm stuck and I'm using the same panel as you but its saying trouble on dvc

  • @binumalikjimeta2877
    @binumalikjimeta2877 5 лет назад

    Can addressable zeta panel be connected to a sprinkler panel for normal operation

  • @pyrotech8877
    @pyrotech8877  10 лет назад +1

    Make sure to check out our Facebook Group Titled "Fire Alarms Online for NICET" tons of info. Join today!

  • @rajkumargupta1158
    @rajkumargupta1158 4 года назад

    Good job

  • @poohsouvannavong2944
    @poohsouvannavong2944 6 лет назад

    Kyle, once the customer ACK the system how long before the trouble or supervisory piezo kicks back in? Is it something you program or is it built into panel or code requirement? Thanks!

  • @irwansaputra5477
    @irwansaputra5477 5 лет назад

    Hello. I want to know, how to repaire if the mcfa panel any trouble as ground fault loop? any some one could to help me explain this trouble?

  • @jhonatansuasnabarvivanco489
    @jhonatansuasnabarvivanco489 10 лет назад +1

    why I can turn off the strobes?

  • @severedronin
    @severedronin 10 лет назад +1

    I'm a security officer in charge of one of these systems. Recently the system started giving us an error when we attempt to acknowledge an alarm. It gives us 'Function Locked Out' and we're unable to acknowledge anything. Has this happened to anyone and how do we sort it out?

    • @isthattrueornot
      @isthattrueornot 6 лет назад

      Severed Ronin have you sorted the problem at last or not. if so please specify me what u done for solving it.

  • @OrthodoxChristianBeliever
    @OrthodoxChristianBeliever 7 лет назад

    also, how can three devices set a whole building into evac if all the others do fire floor, floor above, and floor below?

    • @pyrotech8877
      @pyrotech8877  7 лет назад +1

      LTCWM1 it's all done through programming. you can use groups, zones or devices via boolean logic statements to do virtually anything.

    • @OrthodoxChristianBeliever
      @OrthodoxChristianBeliever 7 лет назад

      Kyle J. Schuler, SET, that's interesting. I've never heard that or read about that before. Do other panels do that? I mean like the simplex 4100, Edwards, does firelite even do that?

    • @RobertAslinMusic
      @RobertAslinMusic 6 лет назад

      The 4100ES, EST3, and the Gamewell-FCI E3 can certainly do that, as they are all large addressable panels. But I think since Fire-Lite makes panels for much smaller installations, you may not be able to do that.

  • @SomeDudeWithAnExitSign
    @SomeDudeWithAnExitSign 3 года назад

    My midfle school has this panel without the dvc

  • @muhammadjawadhaider2152
    @muhammadjawadhaider2152 4 года назад

    Around? I have a question

  • @user-bm7fj4dz4y
    @user-bm7fj4dz4y 10 лет назад +1

    Hello how are you
    Can you help me
    I have the same fire alarm system
    I want a scheme linking and connecting devices

  • @pyrotech8877
    @pyrotech8877  11 лет назад

    It was an addressable Simplex

    • @yilancio
      @yilancio 6 лет назад

      put your glasses on, that's a lame Notifire/Honeywell. A Simplex panel is nowhere near as ugly and confusing to the owner/end user. Simplex panels are unquestionably the finest fire detection panels, although not the cheapest.

    • @FireTech7
      @FireTech7 4 года назад +2

      @@yilancio simplex is garbage man it's nowhere in sight nobody wants to spend so much money on something that will do that same thing and may even have more features

    • @drballzack
      @drballzack 4 года назад +1

      @@FireTech7 simplex is a p.o.s. they do however have the world's greatest sales people cuz how else would they convince people into having such a shitty fire system.

    • @Roxxofoxxo
      @Roxxofoxxo 3 года назад

      @@yilancio Lol simplex sucks and is grabage. Simplex? More like complex!

  • @DMB7962
    @DMB7962 10 лет назад

    Kyle, being that this is a central station alarm system, whose job is it to know AHJ/local fire codes on silencing alarms?
    Thanks!

    • @pyrotech8877
      @pyrotech8877  10 лет назад

      I would say both the installer and the end user. Check with the local AHJ to get their standards on this practice.

    • @DMB7962
      @DMB7962 10 лет назад

      Thanks. In this video, are you representing the installer?

    • @pyrotech8877
      @pyrotech8877  10 лет назад

      Yes

  • @MichaelYar2004
    @MichaelYar2004 10 лет назад +1

    Do a system test

  • @farizdavlatov1956
    @farizdavlatov1956 11 лет назад

    How to fix STYLE 6 SHORT L7 ??

  • @ahmedmahgoub9789
    @ahmedmahgoub9789 8 лет назад

    Dear Sir can you help me with the this panel software if you have it

    • @pyrotech8877
      @pyrotech8877  7 лет назад

      Ahmed Mahgoub can't give it up unless you are an authorized Notifier ESD.

  • @crayons071
    @crayons071 5 лет назад

    What school do you have to go to get certified?

    • @adamcuttler9665
      @adamcuttler9665 3 года назад +1

      Notifier school and nicet

    • @crayons071
      @crayons071 3 года назад

      @@adamcuttler9665 do you know of a school that trains for a Simplex fire alarm?

    • @adamcuttler9665
      @adamcuttler9665 3 года назад

      @@crayons071 I will find out today buddy I know guys that used to work at simplex.

    • @adamcuttler9665
      @adamcuttler9665 3 года назад

      He said no real outsource training he learned on the job with the old timers but he got his nicet one and two at simplex. And guys with 30 and 40 years in the field taught him kitchen hoods FM 200 fire extinguishers he learned on the job

  • @OrthodoxChristianBeliever
    @OrthodoxChristianBeliever 7 лет назад

    w is a loop number versus a zone number?

    • @Roxxofoxxo
      @Roxxofoxxo 3 года назад

      Loop number is the actual devices number while a zone is a group a point on a loop could be assigned

  • @user-bm7fj4dz4y
    @user-bm7fj4dz4y 10 лет назад

    Hello how are you
    Can you help me
    I have the same fire alarm system
    I want to link the scheme and Thesel devices

    • @sabirahman5040
      @sabirahman5040 6 лет назад

      صالح هاشم الجبيلي yes u can call me at 9004942637 india code is +91 i will help u at wassap call if u have any problem ok

  • @djjammindave
    @djjammindave 5 лет назад

    FIRE ALARM TRAINING VIDEO - Not even a button was pushed on the panel. Unbelievable 😒

    • @pyrotech8877
      @pyrotech8877  5 лет назад

      This was filmed on site for a customer. The actual site testing and full function demo was completed after this discussion.

  • @uofksteel
    @uofksteel 10 лет назад +2

    What a piece.....should have went back to a Simplex system

    • @bangemblack5888
      @bangemblack5888 5 лет назад +1

      Simplex system sucks

    • @aspenqwerty3
      @aspenqwerty3 5 лет назад

      @@bangemblack5888 dont know what generation you are coming from... simplex is top notch system today...

    • @bangemblack5888
      @bangemblack5888 5 лет назад

      @@aspenqwerty3 at my job I came across more of the older systems a lot down here in my area

    • @FireTech7
      @FireTech7 4 года назад +1

      @@aspenqwerty3 lol you must be living in the past I don't see any simplex in any new buildings it's all silent knight

    • @irich1348
      @irich1348 4 года назад

      @@bangemblack5888 y?

  • @hanifariyas4658
    @hanifariyas4658 7 лет назад

    The

  • @wilson9hern
    @wilson9hern 8 лет назад

    Female Was Rule Being in The Phone While The Public is Trying To Listen

  • @firenetcolombia9248
    @firenetcolombia9248 4 года назад

    Venta el verifiretools al correo taradini@hotmail.com

  • @ferbbylove7083
    @ferbbylove7083 9 лет назад +1

    👎👎👎👎

  • @ferbbylove7083
    @ferbbylove7083 9 лет назад

    Buuuuu!!