How To Enable/Disable A Device on the Notifier NFS2-3030

Поделиться
HTML-код
  • Опубликовано: 8 янв 2025

Комментарии • 27

  • @nics-systems-electric
    @nics-systems-electric Год назад

    Done it 100's of times but still kept me entertained for five minutes lol

    • @FireTech7
      @FireTech7  Год назад

      That's what I like to see lol

  • @leninho10
    @leninho10 Год назад +1

    Very good!
    A question! Is there the possibility of testing a Detector directly through the Central? In other words, enter the desired point and check its activation!

    • @FireTech7
      @FireTech7  Год назад +1

      If you are referring to its values and whatnot to see if it's currently activated, then yes. You can not put the detector into alarm from the control panel itself, though. At least I don't think you can.. I'll check tomorrow

    • @leninho10
      @leninho10 Год назад +1

      @@FireTech7 @FireTech7 In fact, I already did a test on the audio visual, however, activating a Detector through the Central I couldn't find any actual function!
      I've worked with other centers that had this option directly on the panel.

    • @FireTech7
      @FireTech7  Год назад +1

      @leninho10 Yeah, I know est and Silent Knight have those features, but I do not think notifier does

    • @leninho10
      @leninho10 Год назад +1

      @@FireTech7 Thank you for the information!

  • @ellieesther4484
    @ellieesther4484 7 месяцев назад

    Thanks for this. The building my on-site is in has this fire panel.

  • @hammockmoh8829
    @hammockmoh8829 Год назад +1

    Hi is it possible to disable NAC ? How is the method if can ?

  • @achannelwithnopurpose1977
    @achannelwithnopurpose1977 Год назад

    I like the setup. Are you gonna program the piezo to be disabled on the annunciators attached to the panel? Can the annunciator piezo be programmed to not sound?

    • @FireTech7
      @FireTech7  Год назад

      I would just flip one of the dip switches on the back of it to the off position, I do that when the panel gets rebooted because during that time the acs bus shuts down and that acm goes into a com trouble and starts beeping. As for it being on the active system, I sort of like when multiple piezos go off at once, so I think I will keep it enabled.

  • @TECMARHN
    @TECMARHN 5 месяцев назад

    Hi, how can you disable a range of devices at once? is it possible?

  • @hariharasudhane5432
    @hariharasudhane5432 3 месяца назад

    Sir detector alarm valve and pre alarm valve how to reset?

  • @turyanazrogluclilov9045
    @turyanazrogluclilov9045 3 месяца назад

    Hi Sir, could you please any advise . In my alarm panel have one trouble : No power supply inst . power supply is ok, i made reset also, still showing this strouble.

    • @FireTech7
      @FireTech7  3 месяца назад

      What's the slc address of the power supply

  • @TECMARHN
    @TECMARHN 5 месяцев назад

    Hi, how can you disable a range of devices at once?

    • @FireTech7
      @FireTech7  5 месяцев назад

      Disable the zone or zones in which those devices are programmed to

  • @LoucifMarouane
    @LoucifMarouane Месяц назад

    The meaning of module desable it's all detector present on this zone are inhibited????

    • @FireTech7
      @FireTech7  Месяц назад

      Module disable will let you disable any module type programmed into the system. Control, relay, or monitor modules.

  • @kashifdahri8478
    @kashifdahri8478 10 месяцев назад

    Sir i am getting dual/double address error/alarm on my panel for some of the smoke detectors. I have tried to auto program but still issue exists please guide.

    • @FireTech7
      @FireTech7  10 месяцев назад

      That means you have devices in the field that have the same address, you need to find those devices and change the address

  • @SodiumInduction-hv
    @SodiumInduction-hv Год назад +1

    Very interesting

  • @sonuraghav394
    @sonuraghav394 8 месяцев назад

    Sir mere pass ye keyboard hia. Sale krne hai

  • @kashifdahri8478
    @kashifdahri8478 10 месяцев назад

    And also getting the alarms for. ANNUN 1 NO ANSWER
    ANNUN 2 NO ANSWER
    Please guide

    • @FireTech7
      @FireTech7  9 месяцев назад

      There are 2 annunciators programmed into the system that either donr exist or are disconnected from the panel, they can range from acm-24at to lcd-160, find them or delete them from the programming than reboot the panel

  • @patcarbone1753
    @patcarbone1753 Год назад

    Very cool!!

  • @syedwasay-bh6zl
    @syedwasay-bh6zl 8 месяцев назад

    Super