Klein Non-Contact Voltage Tester Review

Поделиться
HTML-код
  • Опубликовано: 26 авг 2024

Комментарии • 55

  • @ZachFields
    @ZachFields  4 года назад

    Dual-Range Tester:
    amzn.to/2SDd6Gn
    Single-Range Tester: amzn.to/2u0zqj4
    Disclaimer: Zach Fields may earn an affiliate commission when you buy through the links here.

  • @t.s.9656
    @t.s.9656 6 месяцев назад

    This is the best instructional video on this item I've seen. Thanks.

  • @melodychest9020
    @melodychest9020 2 года назад

    Good video and nice demo! The one I bought today kinda had a knocking sound inside with the batteries having play width-wise and annoying. I cut a long piece of plastic from the packaing and filled one side of the battery hole after battery insersion. This makes it a very snug fit and the batteries are now held tight with no play or noise. Only deal is I have to employ needle nose pliers to pull the plastic out when the batteries need swapping! Small quality control slip ups like this one is pretty annoying. In fact the whole battery compartment and closing cap needs redesigning as is pretty suspect to me. It is a delicate fitting exercise and if the plastic cap breaks at some point, the whole thing is rendered useless. This is where companies like Fluke make that difference in quality I guess. I enjoyed the video very much, thanks! :-)

  • @megdahlin1118
    @megdahlin1118 Год назад

    Just looked at your video. Great explanation and demo. Sensitive indeed! I was wondering how the disco'd wires in the junction box that I'm taking down were still indicating intermittently when touched a little while ago. I knew there was no power going to them so this video gave me the why on that. Thanks! Just subscribed.

  • @leef8063
    @leef8063 5 лет назад +2

    Thanks for the video, mine was acting strange. I realized I hadn't changed the batteries since I bought it. Mine kept switching and beeping plus when bumped would read positive.

    • @ZachFields
      @ZachFields  5 лет назад

      Yeah, unfortunately due to the sensitive nature of these meters you can get a false positive by bumping it against something. As you noted, fresh batteries do help. 🙂

  • @joeybooks4758
    @joeybooks4758 3 года назад +2

    I turn the fuses off for lights for the entire floor as I was installing new lights but did not have a voltage tester big mistake as the building was over 50 years old other people just wired the power to the light to a wrong fuse. As soon as I tried to wire the light in the second biggest shock of my life almost knocked me out fell limp on the ladder 8 feet off the ground could not use my hand for 5 mins.

    • @ZachFields
      @ZachFields  3 года назад

      Wow, what a story! Yep, you can't be too careful with wiring especially in old buildings like that.

  • @1054MACK
    @1054MACK 4 дня назад

    Will this tester detect ground wires

  • @marcmondragone3452
    @marcmondragone3452 3 года назад

    Went to hime depot today. The hangers where empty, Most of them have been recalled. Except for a one priced at 28 bucks.

  • @debbietuson7591
    @debbietuson7591 Год назад

    How do you change the batteries......

  • @sipankh
    @sipankh 2 года назад

    How do you explain that it provides sound signal and LED light blinking on a dead wire that is not connected to any power source - like the wire has low level voltage - does mean defective? All other functions are as you describe it, and your video is so far best description on how this tool works. Even Klein's official video's are joke comparing to this simple and on point how to use this device video.

  • @heretohear8662
    @heretohear8662 4 года назад +1

    Thanks so much! Great info and vid!

  • @elvinzapata4695
    @elvinzapata4695 2 года назад

    Great informative video. Thank you.

  • @Brianmw305i
    @Brianmw305i 2 года назад

    Would this work on high voltage batteries, like those Tesla.. they used DC current.. is this only for 120v?

  • @heretohear8662
    @heretohear8662 4 года назад +1

    I have a box in the wall that runs a light over the sink and was also hard wired into a dishwasher, which has been remove. The previous owner also hooked the garbage disposal under the sink to the same box and it is that wire that is stuck behind the wall that I unhooked and need to test to make sure there is no electricity running through it.
    Am I able to ...once the power is on, test the wire leading behind the wall, able to confirm there is a dead wire and not a live wire back there??? So sorry for that long explanation.

    • @ZachFields
      @ZachFields  4 года назад +1

      @Here to Here for the situation you described, you should really check the circuit in question with a digital multimeter to confirm that it is dead.

  • @ericseegers5950
    @ericseegers5950 2 года назад

    What is the rapid beep vs the slow beep?

  • @nancybryson5488
    @nancybryson5488 4 года назад +1

    Thanks for demonstrating that one can get a "false positive" with this tool (red flash despite zero voltage). Question: Does this tool only detect AC voltage? Or also DC voltage? (Probably a dumb question.)

    • @ZachFields
      @ZachFields  4 года назад +1

      @Nancy Bryson
      Good question. These will only detect AC voltage, not DC.

    • @melodychest9020
      @melodychest9020 2 года назад

      @@ZachFields I guess for DC you use a Multimeter then?

  • @BIGFOOT.
    @BIGFOOT. 6 месяцев назад

    Could this detect spy cams?

  • @user-vi1rc1nc6c
    @user-vi1rc1nc6c Год назад

    How to order

  • @user-vi1rc1nc6c
    @user-vi1rc1nc6c Год назад

    How much i want to order

  • @omarpreza6387
    @omarpreza6387 3 года назад

    Thanks for you help

  • @scrface-nl2rb
    @scrface-nl2rb 4 года назад +1

    Great info thank you !!!!

  • @cjr0704
    @cjr0704 2 года назад

    Mine has no blue light. Also never red on any circuit

  • @paulsoutbackgardenaustrali7674
    @paulsoutbackgardenaustrali7674 4 года назад

    Thanx...I'm sold ..I'm going to buy 1 this work and do some farm electrical lighting work..

  • @okaythen001
    @okaythen001 4 года назад

    Can I use klein non-contact tester on capacitors? Will it beep if it's not discharged?

    • @ZachFields
      @ZachFields  4 года назад

      I wouldn't recommend it.

  • @cslloyd1
    @cslloyd1 3 года назад

    why does my neutral wire never trigger the detector, even when the object being powered up is ON? I would assume there is current in the neutral wire (otherwise what dies it do?) and I should think it would be dangerous to touch. But my Fluke detector never triggers on the neutral no matter if there's current or not.

    • @dustinpomeroy8817
      @dustinpomeroy8817 2 года назад

      Is this a serious question?

    • @cslloyd1
      @cslloyd1 2 года назад

      @@dustinpomeroy8817 sounds you you don't know the answer.

    • @dustinpomeroy8817
      @dustinpomeroy8817 2 года назад

      There should not be power in the neutral wire or the ground wire.The the only wire that should have power is the hot one.

    • @cslloyd1
      @cslloyd1 2 года назад

      @@dustinpomeroy8817 so you don’t understand the question. Not “power”, “current”. Electrons moving back and forth.

    • @dustinpomeroy8817
      @dustinpomeroy8817 2 года назад

      @@cslloyd1 yeah there's no current in a neutral wire

  • @jeanturcot728
    @jeanturcot728 3 года назад

    Can the current for a 220 volt heater be tested? Thanks

    • @ZachFields
      @ZachFields  3 года назад

      Yes, it will work for a 220 circuit. Remember, however, this is only a safety check. If you're having problems with a circuit or device, you'll need a multimeter to troubleshoot the issue.

  • @eugenecbell
    @eugenecbell 4 года назад

    how can it tell the hot from the neutral? Both have AC current flowing through them and both create magnetic fields.

    • @ZachFields
      @ZachFields  4 года назад +1

      @Eugene Bell I must admit I’m in a bit over my head for the finer technical details. My research in prep for shooting the video was not conclusive on this.

    • @eugenecbell
      @eugenecbell 4 года назад

      Zach Fields, very good. Thank you for the videos.

    • @bitTorrenter
      @bitTorrenter 4 года назад

      This is why people go to technical college where they will explain this.

    • @eugenecbell
      @eugenecbell 4 года назад

      bitTorrenter, explain that the hot and neutral create identical magnetic fields, so cannot be distinguished.

    • @sectokia1909
      @sectokia1909 3 года назад

      No current is required to be flowing in the AC circuit (ie. no load).
      These sticks work only if the user is grounded, because they are a capacitor, when it comes close enough to an active wire, the change in capacitance from the electric field of the live wire can be sensed because current will be drawn up and down from earth through the user to the tip of the pen to the electric field of the live wire. Because neutral is connected to earth - which is connected to pen, the pen will not trigger on neutral even if it has current.

  • @josher3436
    @josher3436 4 года назад +1

    Non-contact Voltage Testers are for Testing for Live, they should never be used to Test for Dead.

  • @ICSpotz
    @ICSpotz 3 года назад

    Essential piece of equipment?... not for me, mine gives false positives on both live and dead outlets and switches, with breakers off it shows live and I have to verify with a VOM, neon tester or plug in a lamp to verify off condition....went back to other ways of testing a circuit and quit wasting my time with the Klein NCVT

  • @5tuhft104
    @5tuhft104 2 года назад

    🇰🇷💗

  • @markotterby4297
    @markotterby4297 4 года назад +1

    Just bought one and only the green light comes on no matter what I touch...a live wire or a live outlet. And what is this crap about having to touch both sides of a live romax to detect voltage???? This should detect voltage by just touching the romax anywhere! This is junk! I had to cancel my job today because of this piece of crap.

  • @tonylarge5298
    @tonylarge5298 2 года назад +1

    don't trust this tool. I always pack my ac/dc tester. Klein should have a class action against them for this poor product.

  • @jessegarcia5056
    @jessegarcia5056 4 года назад

    That one is no good will work for a little while but don’t trust your life with it

  • @lawrencehawkins7198
    @lawrencehawkins7198 4 года назад +3

    Had I known this was made in China I would NEVER have ordered one. :( #BoycottChina