  • @ashishtripathi4882
    @ashishtripathi4882 5 лет назад +2

    I happen to notice there is a mistake in the first example of that fAR problem. Its written 12000/100,where it should be 12000/1000. Otherwise you will have 120 floors.

  • @jelecomonlinetechnicaltrai7480
    @jelecomonlinetechnicaltrai7480 2 года назад

    Many Thanks.
    Very nice presentation.
    Kindly, we need another presentation about High Rise Building Fire Fighting &Fire Protection

  • @arunkumarkanchuboyina
    @arunkumarkanchuboyina 2 года назад

    Excellent presentation sir. This will help as a quick summary of reference of fire-fighting design. Expecting a similar PHE presentation also from you very soon.

  • @amruthagosukonda6821
    @amruthagosukonda6821 3 года назад

    very good sir, and very nicely stated points which are very important and basic.

  • @Kent12178
    @Kent12178 5 лет назад

    Thanks a lot. You are doing great public service.

  • @rahulpurchase2748
    @rahulpurchase2748 5 лет назад +1

    Adding to all above stated points which are very important and basic.
    Can we make slow spread of fire by introducing more fire retardant materials ?
    Is there any code for fire rating of building material ?
    As many new interior materials are used now a days and most of them are highly flammable.
    How to test the amount of smoke and toxicity of gases developed in case of fire of building materials ?

  • @karthikumar4325
    @karthikumar4325 Год назад

    The fire norms building height is considered in oht tank or building top floor slab finish level

  • @1000chotta
    @1000chotta 5 лет назад

    Good explanation of basic parameters of fire fighting. But it varies from case to case.

  • @essakipandi4033
    @essakipandi4033 4 года назад

    Dear Ashok Sir, very well explained and the content was well prepared to understand. just came across your presentation today. do you have more presentation of this course.

  • @indiangreenwarrior6543
    @indiangreenwarrior6543 4 года назад

    Sir, if we notice any building residents violating the fire safety rules by blocking the fire extinguisher with their belongings. Whom should one complain to if the builder himself cannot do anything to solve the issue?

  • @mrmprm8732
    @mrmprm8732 3 года назад

    What is the setback space needed for access by fire fighting vehicle on each of 4 sides of 70m tall building in Mumbai island? The building has 21.3m wide road on East and 12m wide road on North

  • @PoojaGupta-fi2fj
    @PoojaGupta-fi2fj 5 лет назад +2

    Hello sir
    Can we use fire protection system for 8 mtr height of govt official building?
    If , then which type of fire protection is used for same

    • @Aviator77186
      @Aviator77186 4 года назад

      First aid fire fighting extinguishers are sufficient.... Mainly DCP, CO2 & WATER BASED

  • @MEPPRO
    @MEPPRO 4 года назад

    Sir, for Apartments you have taken above 15mtrs requirements. In NBC part 4 below 15mtrs requirements for dormitory and apartments are mentioned. Whether it need to consider or not?

  • @drganapathibhatmanchi3263
    @drganapathibhatmanchi3263 5 лет назад

    Many thanks, very specific info

  • @nil8500
    @nil8500 4 года назад

    We have new 22 floor story building and builder locked the terrace, is it legal as if fire blow in building? What is rule of terrace open

  • @ahmedshaikh6270
    @ahmedshaikh6270 6 лет назад +1

    How will the pump in the Wet riser work when there is an electricity cut off ?

    • @manoj1982able
      @manoj1982able 6 лет назад

      The entire pups will smartly behave after switching on DG pump which is already installed in pump room..

    • @FireFightervinodkaswan
      @FireFightervinodkaswan 5 лет назад

      For Visit My Channel Here videos all Fire Safety

    • @pheandfireconsultants-manj5333
      @pheandfireconsultants-manj5333 4 года назад

      Dear ahmed shaik during the emergency the electrical services required for the fire protection is isolated hence during the emrgency the electrical supply for the main pumps still works

  • @nublanabd6409
    @nublanabd6409 2 месяца назад

    nice

  • @manjumathi5235
    @manjumathi5235 6 лет назад

    Thank u so much sir..i'll be more helpful

  • @josephpawar1350
    @josephpawar1350 4 года назад

    Thanks sir

  • @yoftaheetta8906
    @yoftaheetta8906 5 лет назад

    thank you

  • @danishansari8103
    @danishansari8103 5 лет назад

    It's very difficult to understand.