PowMr New Version keeper Charge Controller Setup

Поделиться
HTML-код
  • Опубликовано: 12 окт 2024
  • In this video we will show you how to set up the PowMr new version keeper charge controller. Unlock the full potential of solar power with this easy-to-follow installation tutorial.
    ______________________________________________________________
    Website
    powmr.com/
    Facebook
    / powmrsolar
    Email:
    support@powmr.com
    See you in my next video! :)
    ______________________________________________________________
    1: PowMr keeper Charge Controller Setup
    • PowMr keeper Charge Co...
    2: PowMr 60A MPPT Solar Charge Controller Setup
    • PowMr 60A MPPT Solar C...
    3: Discover the Cutting-Edge Features of the Charge Controller by Powmr!
    • Discover the Cutting-E...

Комментарии • 183

  • @asadahmed4708
    @asadahmed4708 Год назад +10

    Please remake the current manual book with full details and adding this function,i already bought this 20 amp controller and confused about some function because the current manual book don't have written the function's about you told

  • @md.mashiurrahman4678
    @md.mashiurrahman4678 21 день назад

    I am currently working with a 24V solar panel 250 Watt and a 12V battery 100 Mah . Could you please advise if it is possible to safely use this setup?

    • @PowmrSolar
      @PowmrSolar  20 дней назад

      Please send your problem to this email: support@powmr.com.

  • @jethroasuncion6080
    @jethroasuncion6080 8 месяцев назад +1

    Hi! I am using the 1230 model with a 24V Gel battery bank setup. Note that I am using the preset parameters for GEL type batteries. The charge controllers indicate that I have a 23V power input however it shows that there is no charge current. Batteries are currently at 25.1V, if I am correct, according to the settings, this controller should start charging the batteries. Am I doing something wrong?

    • @PowmrSolar
      @PowmrSolar  7 месяцев назад +1

      Hi, please send your problem to this email: support@powmr.com. Please note that we may not be able to promptly respond to you due to the Lunar New Year. We apologize for the inconvenience this may take and thank you for your understanding. We wish you all the best!

  • @matttelz6014
    @matttelz6014 7 месяцев назад +1

    How to I adjust the Resume charge voltage? With Lifepo4 setting it is 13.0V which is too low.

    • @PowmrSolar
      @PowmrSolar  7 месяцев назад

      Please set the battery type to USE1 so that you can adjust the parameters yourself.

  • @ronversluys1235
    @ronversluys1235 Год назад +1

    I am trying to figure out the LiFePO4 battery setting . I see in the instructions that they have listed LiPo and LiFe. When I enter that I have a 4-3.2v battery I get the symbol of LiFe. I have never seen the LiPo symbol. My question is do I have it set right? Thanks

    • @PowmrSolar
      @PowmrSolar  Год назад

      Hi, please send your problems to this email: support@powmr.com

  • @Jayromemagtipon07
    @Jayromemagtipon07 10 месяцев назад

    Hi. If i use 3-3.7 lipo battery still i need bms or no need

  • @ronversluys1235
    @ronversluys1235 Год назад +2

    Can anyone tell me if by picking the 4-3.2v battery then the LiFe symbol shows on the screen, are the charging parameters picked for me? I have a LiFePO4 battery and i dont need the resume, the constant voltage, equalization and absorption charge. All I need is the Low voltage protection and Float charge, Please correct me if I am wrong. Please tell me how to set this controller up correctly. Are the charging parameters user adjustable? Thanks

    • @PowmrSolar
      @PowmrSolar  Год назад

      Hi, please send your problems to this email: support@powmr.com.

    • @martinwragg8246
      @martinwragg8246 9 месяцев назад

      Hi, did you get an answer to your questions, I am going around in circles here !

    • @ronversluys1235
      @ronversluys1235 9 месяцев назад +1

      @@martinwragg8246 I got no help from powmr support. I studied every you tube I could find and eventually put my project on a shelf for later. I did feel by trying different button pushes I did get better at it but in the end I dont know if its set up right. I have an Epever MPPT that has a remote programer (M50 i think) that is much more user friendly and not much more money.

    • @bustersbashers2280
      @bustersbashers2280 6 месяцев назад

      Same here….!

  • @coupleadventure
    @coupleadventure 3 месяца назад

    I already have this same model, but how to activate the rotation display like the old model so i dont have to operate the botton just to see some details on display..

    • @PowmrSolar
      @PowmrSolar  3 месяца назад

      Please send your problem to this email: support@powmr.com.

  • @martinwragg8246
    @martinwragg8246 9 месяцев назад

    Can 3 of these work in parallel connected to the battery with separate solar panels connected to each solar controller?

    • @PowmrSolar
      @PowmrSolar  9 месяцев назад

      Hi, this model can't be used in parallel.

  • @MdSumon-ii9zr
    @MdSumon-ii9zr 3 месяца назад

    A few days ago, I bought the 30 amp machine that connected a Jinko 580-watt 24-volt panel. I am not getting any response from this machine, although the weather in my area is not good, the sun has not risen due to rain. Will I get no output from this controller if it's not sunny?

    • @PowmrSolar
      @PowmrSolar  3 месяца назад

      Please send your problem to this email: support@powmr.com.

    • @MdSumon-ii9zr
      @MdSumon-ii9zr 3 месяца назад

      @@PowmrSolar How to turn on photovoltaic input?

    • @PowmrSolar
      @PowmrSolar  3 месяца назад

      @@MdSumon-ii9zr Kindly check your email.

    • @MdSumon-ii9zr
      @MdSumon-ii9zr 3 месяца назад

      @@PowmrSolar please send

  • @martinwragg8246
    @martinwragg8246 9 месяцев назад +1

    Can the firmware be updated?
    I have V1.4

    • @PowmrSolar
      @PowmrSolar  9 месяцев назад

      Please send your problems to this email: support@powmr.com

  • @ritchiegarcellano8382
    @ritchiegarcellano8382 Год назад

    Hello maam. Im already bought powkeeper 1230. Same as your MPPt. Can i ask?. How about reserved settings if long press the MENU,will shown 19.2 directly. Its ok for that. My battery is 12v system. Sealed Lead Acid battery

    • @amyliu5169
      @amyliu5169 Год назад

      Hi dear sir, could you tell me which setting parameter you are asking? (the charging voltage? or the battery type?) Let me have a check for you.

    • @ritchiegarcellano8382
      @ritchiegarcellano8382 Год назад

      The last settings that i have shown, no01 or reserved settings, or nevermind that settings, because if put press MENU 3s will shown, other settings

    • @wzjiang856
      @wzjiang856 11 месяцев назад

      this setting is for RS485 comunication baudrate, 19.2 means 19.2K , this fuction reserve for future only @@ritchiegarcellano8382

  • @Aurthermorgan02
    @Aurthermorgan02 3 месяца назад

    Hi... May I limit the ampere i want to charge the battery.... I want my battery will be charged at 5 amp and extra ampere, is it possible from user setting?

    • @PowmrSolar
      @PowmrSolar  3 месяца назад

      Nope, this cannot be set.

  • @01lovemusic01
    @01lovemusic01 7 месяцев назад

    Hi! I have two 260AH LifePo4 batteries 🔋🔋 Can you please me how to set into Powmr Power keeper 30A for this? 14.6V what mode? Is that USER2? Thanks.

    • @PowmrSolar
      @PowmrSolar  7 месяцев назад

      Hi, please send your problems to this email: support@powmr.com. Our Technical staff will handle it for you.

    • @01lovemusic01
      @01lovemusic01 7 месяцев назад

      @@PowmrSolar I did send it on March 08 but I got no response!

    • @PowmrSolar
      @PowmrSolar  7 месяцев назад

      @@01lovemusic01 Can you send us your email?

  • @moesuki2810
    @moesuki2810 Год назад +1

    The maximum value of the output load terminal is approximately how many amps?

    • @PowmrSolar
      @PowmrSolar  Год назад +3

      5A.

    • @adofatma2400
      @adofatma2400 4 месяца назад

      ​@@PowmrSolarthe manual book says DC output rated discharge current is 20A for 1220 and 1230, and 30A for 1240. Which one is correct?

    • @PowmrSolar
      @PowmrSolar  4 месяца назад

      @@adofatma2400 Yep, the rated charge current is 20A for 1220; 30A for 1230; 40A for 1240.

  • @lufemendes
    @lufemendes 9 месяцев назад

    Hi, I'm having an issue with my Keeper 1230 controller. The display isn't cycling through the different screens like current, voltage, and temperature. Any advice on fixing this? Thanks!

    • @PowmrSolar
      @PowmrSolar  9 месяцев назад +1

      Hi, kindly send your problems to this email: support@powmr.com

    • @luizhenriquemerhy1640
      @luizhenriquemerhy1640 9 месяцев назад +2

      É a versão do software instalado. O meu é U1.4 é também não fica trocando e os icones no display no LCD são diferentes dos que ficam mudando os dados, è igual ao deste video acima que também não muda .

    • @lufemendes
      @lufemendes 9 месяцев назад

      @@luizhenriquemerhy1640 Valeu, amigo!

  • @patrickc.3185
    @patrickc.3185 11 месяцев назад

    Hi, I'm using the POW-Keeper 1220. I selected SLD in the controller because based on the manual, if you are using a Sealed Lead Acid Battery of 12V, you should select SLD. My problem is in the SCC, the LVD is set too low at 10.8V. How can I change it to 12.0V? I long press the MENU button while LVD is selected but nothing happens. I need to increase the LVD to protect my battery.

    • @PowmrSolar
      @PowmrSolar  11 месяцев назад

      Please change the battery type to USR1 or USR2 before setting it up. If SLD is set, the system will automatically default LVD to 10.8V and cannot be modified.

    • @patrickc.3185
      @patrickc.3185 11 месяцев назад

      @@PowmrSolar Thank you. I will try setting it on USR2 and let you know if it will be successful.

    • @PowmrSolar
      @PowmrSolar  11 месяцев назад

      @@patrickc.3185 Okay.

  • @jamescarldelacruzchannel2633
    @jamescarldelacruzchannel2633 Месяц назад

    I have the powmr 1220 version , and why the set AH is not decreasing on discharge AH?

    • @PowmrSolar
      @PowmrSolar  Месяц назад

      Please send your problem to this email: support@powmr.com

  • @ferdoushrahman6802
    @ferdoushrahman6802 2 месяца назад +1

    I want to change the high voltage to 15 volts in lead acid batteries. But how?

    • @PowmrSolar
      @PowmrSolar  2 месяца назад

      Select USE for the battery type, and then adjust it yourself.

  • @danielbituin4382
    @danielbituin4382 Год назад

    Please help how can i set my float votage into 12.6 only beacause im using 3s lithuim ion battery.thanks

    • @wzjiang856
      @wzjiang856 11 месяцев назад +1

      预设的电池类型的参数是默认的, 不能任意调节, 可以选 usr2 用户定义, 大部分参数可以调节.

  • @moesuki2810
    @moesuki2810 10 месяцев назад

    In a 24v load terminal system that supplies 24v, can it supply 12v power?

    • @aleksandersats9577
      @aleksandersats9577 8 месяцев назад

      If you set your batteries to 24v then no. You will need a buck converter to convert that to 12v.

  • @TonsTV13
    @TonsTV13 Год назад

    good day mam., LVD/under volatage protection settings that is ok for GEL 10.1?

    • @PowmrSolar
      @PowmrSolar  Год назад

      Yes, it's Ok.

    • @Jeffersonboncodin
      @Jeffersonboncodin 8 месяцев назад

      What 10.1 low voltage disconnect? GEL is 50/50

    • @jabaguealfredo
      @jabaguealfredo 6 месяцев назад

      you can set the lvd to 12.3 using the usermode 1, when you choose the gel type mode, you cannot configure it manually

  • @put_istine
    @put_istine 12 дней назад

    Seems like a good controller. However, the interface is not very customizable and a bit confusing.
    For example, there is no need for 4 LD options. Can be easily set: [24 h] for constant output, [0 h] at night, that is. it works when the panels are not charging and vice versa and [1-23h] time how long the output works when the panels are not working, [-1h] reverse mode (while the panels are charging). And so instead of 6 setting options, here we have only one parameter that covers all 6 options.

  • @edilbertoego-ogan
    @edilbertoego-ogan 8 месяцев назад

    My Pow keeper1220 new version is not changing display is it good or not ?

    • @PowmrSolar
      @PowmrSolar  8 месяцев назад

      Hi, kindly send your problems to this email: support@powmr.com

  • @maheshindrasingha5923
    @maheshindrasingha5923 11 месяцев назад

    Can I use 7s Lithium-ion battery packs(18650) with 250w solar panels(VMP 30.3v)(voc 38v)?

  • @sunethpriyankara3524
    @sunethpriyankara3524 4 месяца назад

    hi ! I have powmr powkeeper mppt 1220 controller Firmware version v1.7 . i have problem with this controller. i used 12v LiPO4 battery pack. battery is normaly charging ok. but after few hours battery fully charged the controller stoped charging. and i using the battey in day time the battery just keeps going drain and the controller doesn't charge the battery no matter how much sunlight there is.
    There is no such problem with my other controllers. I have a powmr mppt 60A controller, Even after the battery was fully charged during the day. The amount of amperes obtained from the battery is not reduced by the battery and is given from the panels through the charging controller. Now this 1220mppt after fully charging it cut off the solar panels and do not give any output to useing load . Then in the evening, the battery is half depleted. The battery will not be left to use at night.. my english is not good butI hope you understand. how can i fix this. thanks

    • @PowmrSolar
      @PowmrSolar  4 месяца назад +1

      please send your problem to this email: support@powmr.com. Our technical staff will handle it for you.

  • @harrydelara413
    @harrydelara413 Год назад

    Hello,
    Can you help me? I have your product Powmr Keeper Mppt 20A, I am trying to change the Resume Charge to higher voltage like 13.6V but I am not able to set it. This is what I am doing.
    From Main Page > 3seconds Menu button > Resume Charge
    On Resume Charge page I am trying to press Menu for 3 seconds but nothing is happening.
    Battery type is already set to Usr1

    • @PowmrSolar
      @PowmrSolar  Год назад

      Please send your problems to this email: support@powmr.com

    • @harrydelara413
      @harrydelara413 Год назад

      ​@@PowmrSolarI already sent to support, no answer until now.

    • @harrydelara413
      @harrydelara413 Год назад

      ​@@PowmrSolar I'm good now. i used Usr2 instead. I cannot change parameters on Usr1

  • @fnfindingnature
    @fnfindingnature 9 месяцев назад

    I have pow keeper 1220 new version but not changing display data automatically in stanby. Like battery voltage, pv voltage, load etc. Not displaying automatically frequently.

    • @PowmrSolar
      @PowmrSolar  9 месяцев назад

      Hi, please send your problems to this email: support@powmr.com

  • @jayveealvaro8518
    @jayveealvaro8518 9 месяцев назад

    hi im using powmr 1220. Im using GEL battery I set the mppt to gel but the LVD is too low at 10.8V cannot be change to 12.0V how can i change it to 12.0? thank you

    • @PowmrSolar
      @PowmrSolar  9 месяцев назад

      Please send your problems to this email: support@powmr.com

    • @Jeffersonboncodin
      @Jeffersonboncodin 8 месяцев назад

      Me too.. the GEL type is 50/50 DOD.. 10.8V is too low.

    • @PowmrSolar
      @PowmrSolar  7 месяцев назад

      @@Jeffersonboncodin Please send your problems to this email: support@powmr.com

  • @odeiocomunistas
    @odeiocomunistas 6 месяцев назад

    I bought one of these and put it on a stationary 12v battery but it doesn't charge all the way, the battery doesn't last long and turns off the inverter, give me the settings for this type of battery please.

    • @PowmrSolar
      @PowmrSolar  6 месяцев назад

      Please send your question to this email: support@powmr.com.

  • @mannynoleal7521
    @mannynoleal7521 10 месяцев назад

    Is this have a LCD backlight?

    • @PowmrSolar
      @PowmrSolar  10 месяцев назад

      Hi, this model doesn't have a LCD backlight.

  • @user-hershey_2015
    @user-hershey_2015 8 месяцев назад

    This scc protect HVD,LVD....?

    • @PowmrSolar
      @PowmrSolar  7 месяцев назад

      Please send your problem to this email: support@powmr.com.

  • @alanpc16
    @alanpc16 5 месяцев назад

    Tenho uma dúvida.... quando ele entra no modo mppt em 12v qual é a voltagem mínima dos painéis para que ele entra no modo mppt.
    Meu sistema é 12v duas placa de 155w em paralelo e ele não arma o modo mppt é o 1230

    • @PowmrSolar
      @PowmrSolar  5 месяцев назад

      For 12v system: the voltage range is 12V-75V, Max. Input Power: 390w.

    • @eltonveras
      @eltonveras 5 месяцев назад

      Eu acredito que você tem que colocar as duas placas em série para o mppt entrar em ação. Boa sorte.

  • @danielbituin4382
    @danielbituin4382 Год назад

    How can I set up 40A mppt for 3s lithuim battery?I can't see set the float voltage at 12.6

    • @PowmrSolar
      @PowmrSolar  Год назад

      Hi, kindly send your problems to this email: support@powmr.com

  • @okpalamichael4162
    @okpalamichael4162 Год назад

    How can i set the charge controller for 6S (3.7v 18650 lithium battery) lithium battery? Pls reply ASAP

    • @PowmrSolar
      @PowmrSolar  Год назад +1

      You can set USEr1 or USEr2.

  • @marklenrodolfo5030
    @marklenrodolfo5030 Год назад

    How can i reset my powmr mppt same as your video. Becouse my unit is charge at 12.8 in daytime but in 6pm around the voltage shuld drop to 11.9

    • @PowmrSolar
      @PowmrSolar  Год назад

      Hi, kindly send your problems to this email: support@powmr.com.

  • @ThanWin-nn9un
    @ThanWin-nn9un 5 месяцев назад

    I am using POW MR, POW Keeper 1240, SOLAR CHARGE CONTROOLLER.
    The box is showing 'ERRO' and how I can solve this error, please help.

    • @PowmrSolar
      @PowmrSolar  5 месяцев назад

      Please send your problem to this email: support@powmr.com. Our technical staff will handle it for you.

  • @eltonveras
    @eltonveras 5 месяцев назад

    Eu tenho um 1230 com a versão 1.4. Como atualizar para a versão 1.7?

  • @allanenopiaae
    @allanenopiaae 8 месяцев назад

    i use lifepo4 battery and choose setting 4:3.2v..my problem is..error when the voltage are 14v when charging

    • @PowmrSolar
      @PowmrSolar  8 месяцев назад

      please send your problems to this email: support@powmr.com.

  • @diedampfbrasse98
    @diedampfbrasse98 5 месяцев назад

    Update your user manual downloads!!!!
    also would be nice to allow setting the Li capacity in exact values instead of just giving 5AH steps

  • @szkarlatny_pumpernikiel
    @szkarlatny_pumpernikiel 6 месяцев назад

    Hello, to the refreshed product should attach a new manual. I in my product got the old one and it caused me no small problem.
    I also have reservations about the menu on the display, it is so terribly unintuitive until a person is pissed off how to touch it.
    It is user unfriendly!😤

    • @PowmrSolar
      @PowmrSolar  6 месяцев назад

      Hi, sorry for the inconvenience. Please send your questions to this email: support@powmr.com

  • @a.arestovich
    @a.arestovich 5 месяцев назад

    Is it possible to connect the 220 inverter to the controller load instead of the battery?

    • @PowmrSolar
      @PowmrSolar  5 месяцев назад

      You can only connect to the battery.

  • @eumesmo-kd1tr
    @eumesmo-kd1tr 10 месяцев назад

    What are the default values for 24v LiFePO4 Battery?

    • @PowmrSolar
      @PowmrSolar  10 месяцев назад

      Equalized charging voltage
      Maintenance-fee lead acid battery: 14.6V;
      GEL: No; Lead acid flooded battery: 14.8
      Absorption charging voltage
      Maintenance-fee lead acid battery: 14.4V;
      GEL: 14.2; Lead acid flooded battery: 14.6
      Floating charging voltage
      Maintenance-fee lead acid battery,
      GEL, Lead acid flooded battery: 13.8
      Low voltage re-connection
      (LVR)
      Maintenance-fee lead acid battery,
      GEL, Lead acid flooded battery: 12.6
      Low voltage disconnection
      (LVD)
      Maintenance-fee lead acid battery,
      GEL, Lead acid flooded battery: 10.8

    • @eumesmo-kd1tr
      @eumesmo-kd1tr 10 месяцев назад

      @@PowmrSolar thanks a lot but what about LiFePo4 battery at 24 V , BR

    • @PowmrSolar
      @PowmrSolar  10 месяцев назад

      @@eumesmo-kd1tr Generally, you can find the specific reference value of the battery in your lithium battery manual. Then set the battery type to USE on the controller, and you can customize the lithium battery parameters according to the reference values ​​in your battery manual.

    • @eumesmo-kd1tr
      @eumesmo-kd1tr 10 месяцев назад

      @@PowmrSolar yes thanks, i was looking for the values and how to change it, but now i could find it, now i will connect with my other controller in parallel with the same values than my epever controller BR

  • @mohammadniaz1986
    @mohammadniaz1986 4 месяца назад

    I can use 40 amp mppt for my 280 ah tubleal bettery

  • @lexiengapngagap2752
    @lexiengapngagap2752 4 месяца назад

    how can you activate the two usb portals

    • @PowmrSolar
      @PowmrSolar  4 месяца назад

      The controller has an operation mode setting item, which can be set on the Ld4 interface.

  • @lufemendes
    @lufemendes 10 месяцев назад

    Is this a MPPT or a PWM?

  • @mostiboysvlog5695
    @mostiboysvlog5695 Год назад

    How to set float voltage mine is maintain to 13.8 for Lifepo4 battery

    • @amyliu5169
      @amyliu5169 Год назад

      Hi, before you set Float votage, you need to set your battery type "US r1", then set Constant charge voltage and Absorption charge voltage first. Keep the Constant voltage and Absorption voltage are higher than Float votage.

    • @amyliu5169
      @amyliu5169 Год назад

      When you see the interface you want to change the set or parameter, you can long press the "up" button for over 3 seconds, then press "up" or "down" to select the parameter you want to choose. After you selected the parameter you need, long press "up" button again to save the setting selection.

  • @mshah5325
    @mshah5325 Год назад

    Please tell the maximum DC load watts. thank you

  • @MdSumon-ii9zr
    @MdSumon-ii9zr 3 месяца назад

    How to enable equalization mode?

    • @PowmrSolar
      @PowmrSolar  3 месяца назад +1

      Automatic equalization every 28 days

  • @maheshindrasingha5923
    @maheshindrasingha5923 10 месяцев назад

    Hello ..can I use 7s Li-ion battery packs with this ?

  • @koioskobesarmiento9521
    @koioskobesarmiento9521 3 месяца назад

    how to nake the display scroll?

  • @markrichardmabalay6750
    @markrichardmabalay6750 Год назад

    Hello, how to set for 8s lifepo4?

  • @johncarlobernardo866
    @johncarlobernardo866 Год назад

    how to see PV WATTAGE OUTPUT? IN THE NEW CONTROLLER

    • @PowmrSolar
      @PowmrSolar  Год назад

      HI, can't see the PV Wattage directly, but you can see the volts and amperes.

  • @AzizulSarmin
    @AzizulSarmin Год назад

    My dear sister...My have 30A PowMr Mppt Soler charge controller...
    But I Don't no setting ...
    You halp me ...

    • @PowmrSolar
      @PowmrSolar  Год назад

      Hi, kindly send you problems to this email: support@powmr.com

  • @richkhalifha246
    @richkhalifha246 Месяц назад

    Pls is this mppt or pwm

  • @guilhermesilva9280
    @guilhermesilva9280 8 месяцев назад

    Gostaria de um tradução para o português Brasil, estou com dificuldade para configurar o meu pow keeper 1230.

    • @PowmrSolar
      @PowmrSolar  8 месяцев назад

      Hi, please send your problem to this email: support@powmr.com

  • @cenonvillanueva3045
    @cenonvillanueva3045 Год назад

    How to set at low voltage disconnect for lead acid battery

    • @PowmrSolar
      @PowmrSolar  Год назад

      Hi, please send your problems to this email: support@powmr.com.

    • @cenonvillanueva3045
      @cenonvillanueva3045 Год назад

      @@PowmrSolar the lvd of scc is 10.8 , i change of 12.9 but i se the but 10.8 is dont blink i press for 3 second or long press botton up to menu

  • @01lovemusic01
    @01lovemusic01 Год назад

    No option to see PV voltage?

    • @PowmrSolar
      @PowmrSolar  Год назад

      This video is not connected to PV. You can see it directly after connecting to the PV.

    • @amyliu5169
      @amyliu5169 Год назад

      Hi, have you bought the Keeper 1240?@@NeverMind-pk4wz

  • @kmrubel308
    @kmrubel308 Год назад

    What is the way to reset Please tell me a little...

    • @amyliu5169
      @amyliu5169 Год назад

      Hi, there is no reset setting selection on the LCD display.

    • @kmrubel308
      @kmrubel308 Год назад

      Thanks for the reply, it would be nice to have a restart system...

    • @kmrubel308
      @kmrubel308 Год назад

      The product is very good...

  • @josephaltona724
    @josephaltona724 Год назад

    Pa send nga po ng vedio yong new version ng mppt30amper kc herap ng settings nya po

  • @charlesgayon8738
    @charlesgayon8738 Год назад

    Why cant i change the parameters for my batery

  • @marklenrodolfo5030
    @marklenrodolfo5030 Год назад

    What is mean E-11

    • @PowmrSolar
      @PowmrSolar  Год назад +2

      Hi, E11: 12V system battery low voltage protection.

  • @ryuhayabusa3510
    @ryuhayabusa3510 3 месяца назад

    pano mag set up ung latest mppt

    • @PowmrSolar
      @PowmrSolar  3 месяца назад

      what the latest mppt?

  • @terk7121
    @terk7121 Год назад

    The ! symbol always shows what does that mean? what I did wrong.

    • @PowmrSolar
      @PowmrSolar  Год назад +1

      Hi, are there any other fault codes? Only ! symbol?

    • @terk7121
      @terk7121 Год назад +3

      @@PowmrSolar Yes and i also cann't set any parameter when i press the button.

    • @moesuki2810
      @moesuki2810 Год назад +2

      ไม่สามารถตัเงค่า พารามิเตอร์ได้เช่นกัน

    • @poppybusiness
      @poppybusiness Год назад +1

      yes, me too can't set up

    • @Jeffersonboncodin
      @Jeffersonboncodin 8 месяцев назад

      Me too .. complected new version 😢

  • @andersonaraujo5333
    @andersonaraujo5333 9 месяцев назад +1

    wow, this version is very complicated, please go back to the previous version, this one is very bad.

    • @PowmrSolar
      @PowmrSolar  9 месяцев назад

      please send your problems to this email: support@powmr.com.

    • @Jeffersonboncodin
      @Jeffersonboncodin 8 месяцев назад

      Yeah

  • @lucianotavares9378
    @lucianotavares9378 8 месяцев назад

    Preciso de um em português

    • @PowmrSolar
      @PowmrSolar  7 месяцев назад

      Hi, this model(POW-Keeper1220)?

  • @8126926
    @8126926 9 месяцев назад

    keep your finger off the controller until you are actually ready to press a button. you are confusing the crap out of me.

  • @MyintSwe-h3z
    @MyintSwe-h3z 3 месяца назад

    မြန်မာလိုရှင်းပြပါလားခင်ဗျာ

  • @rkradhakrishna5612
    @rkradhakrishna5612 7 месяцев назад

    It is better to give video in Bengali for Bengali

  • @royfitrah8507
    @royfitrah8507 11 месяцев назад

    New version controller

    • @PowmrSolar
      @PowmrSolar  11 месяцев назад

      New version Keeper.

    • @royfitrah8507
      @royfitrah8507 10 месяцев назад

      I like this pow keeper ❤

  • @Jayromemagtipon07
    @Jayromemagtipon07 10 месяцев назад

    And at LVD. Its says 9v cutoff voltage. But i want to increase the LVD to 11.1 or 3.7v per cell. But it can't edit. Its off. How. Can i turn it on to customize LVD 3s Lipo battery. Please help

    • @PowmrSolar
      @PowmrSolar  10 месяцев назад

      Hi, please send your problems to this email: suppoort@powmr.com

  • @sclare5514
    @sclare5514 25 дней назад

    How do you reset the system ?
    It's not charging my lithium ion battery more than 13.6 v even though solar input is 23v Why?

    • @PowmrSolar
      @PowmrSolar  25 дней назад

      Please send your problem to this email: support@powmr.com.

  • @bakalito4601
    @bakalito4601 Год назад

    What are the default values for 24v Gel Battery?

    • @PowmrSolar
      @PowmrSolar  Год назад +1

      Equalized charging voltage: GEL: No
      Absorption charging voltage:GEL: 14.2
      Floating charging voltage:GEL, Lead acid flooded battery: 13.8
      Low voltage re-connection:GEL, Lead acid flooded battery: 12.6
      Low voltage disconnection:GEL, Lead acid flooded battery: 10.8