Fire Water Demand Calculation || Fire Water Tank Capacity Calculation in Urdu

Поделиться
HTML-код
  • Опубликовано: 4 окт 2024
  • This is a fire fighting tutorial video about fire water demand calculation or fire water tank capacity calculation in Urdu. This video contains formulae, examples, differences, and limitations from basic information on fire water demand. It is basic learning of detailed information for Firefighting / MEP technical staff. Here sharing my experience and knowledge that will be helpful to learn & grow for Engineers & Technical staff. If you find anything which is inappropriate then convey it in the comments for my information and rectification in the future.
    Tanweer Ahmed's more fire fighting videos for your watching and learning:
    1. NFPA-14 Pipe Schedule Method for Standpipe
    Video's link: • NFPA 14 Pipe Schedule ...
    2. NFPA-14 Flow Rate Requirements for Standpipe & Hose System
    Video's link: • NFPA 14 Flow Rate Requ...
    3. NFPA-14 Pressure Design Requirements of Standpipe & Hose System
    Video's link: • NFPA-14 Pressure Desig...
    4. NFPA-14 Classes of Standpipe Systems
    Video's link: • NFPA-14 Classes of Sta...
    5. NFPA-13 Pipe Schedule Method Designing
    Video's link: • NFPA 13 Pipe Schedule ...
    6. NFPA-13 Sprinkler Heads Distribution
    Video's link: • NFPA-13 Sprinkler Head...
    7. NFPA-13 Density & Area of Sprinkler Operation
    Video's link: • NFPA 13 Density & Area...
    8. NFPA-13 Sprinklers Discharge Characteristics
    Video's link: • NFPA-13 Sprinklers Dis...
    9. Wet Riser Landing Valve System
    Video's link: • Wet Riser Landing Valv...
    10. Testing of Wet Riser Landing Valve System
    Video's link: • Testing of Wet Riser L...
    11. Fire Hose Reel System
    Video's link: • Fire Hose Reel System ...
    12. Testing of Fire Hose Reel System
    Video's link: • Testing of Fire Hose R...
    13. Converting Pump Head to Pressure or Vise Versa
    Video's link: • Converting Pump Head t...
    14. Difference Between Pressure Reducing & Pressure Restricting Valve
    Video's link: • Difference Between Pre...
    15. Difference Between Pressure Relief & Pressure Safety Valve
    Video's link: • Difference Between Pre...
    16. Combined Firefighting System Water Demand
    Video's link: • Combination Standpipe ...
    17. Types of fire sprinkler systems of fire suppression systems
    Video's link: • Types of fire sprinkle...
    18. Dry Pipe Fire Sprinkler System
    Video's link: • Dry Pipe Fire Sprinkle...
    19. Preaction Sprinkler System NFPA13
    Video's link: • Preaction Sprinkler Sy...
    20. Single Interlock Preaction Sprinkler System
    Video's link: • Single Interlock Preac...
    21. Double Interlock Preaction Sprinkler System
    Video's link: • Double Interlock Preac...
    22. Main Components of Fire Fighting Pump Room Part-1
    Link: • Main Components of Fir...
    23. Main Components of Fire Fighting Pump Room Part-2
    Link: • Main Components of Fir...
    24. Main Components of Fire Sprinkler System Part-1[Except Pump Room]
    Link: • Main Components of Fir...
    25. Main Components of Fire Sprinkler System Part-2 [Except Pump Room]
    Link: • Main Components of Fir...
    26. Testing of Fire Sprinkler System & operation of ZCV assembly
    Link: • Testing of Fire Sprink...
    27. Zone Control Valve | ZCV | Wiring Connection | Fire Alarm Panel
    Link: • Zone Control Valve ZCV...
    28. Fire hydrant locations and Distribution as per NFPA-1
    Link: • Fire Hydrants Location...
    #TanweerAhmed #firewater #waterdemand #tank #firefighting #watertank #mep #formulae #tutorial
    = YOU CAN FOLLOW ME ON SOCIAL MEDIA =
    LINKEDIN: / tanweer-ahmed-00142631
    TELEGRAM GROUP: t.me/hvacmepenggg
    INSTAGRAM: / tanweersethar
    RUclips: / tanweerahmed
    Disclaimer:
    Tanweer Ahmed’s videos are intended solely for educational purposes, aiming to assist junior engineers and technical individuals in enhancing their comprehension of HVAC and MEP engineering basics. The information provided is based on personal experiences and research. It is advisable to consult qualified professionals or adhere to standards before implementing any techniques discussed. Please note that I cannot assure the accuracy or appropriateness of the information presented for your specific situation. Viewers are advised to watch at their own discretion, understanding that I cannot be held responsible for any damages or losses that may occur. Any response does not constitute legal or professional engineering advice. Seeking the advice of a qualified professional specific to your particular application is recommended.
    Thank you for watching, and I hope you find the content helpful.

Комментарии • 67

  • @user-wq2sr2wp4x
    @user-wq2sr2wp4x 3 месяца назад +1

    Sir Thank you very much for sharing a good and valuable information

  • @Islamicindiawala
    @Islamicindiawala 3 месяца назад +1

    Please make a full video on integrity test of FM 200

  • @KhalilAhmad74036
    @KhalilAhmad74036 4 месяца назад +1

    Thanks, for your informative video. Very helpfull!

  • @Zmotivation973
    @Zmotivation973 4 месяца назад +1

    Sir you are doing very well work Allah will grant you in Jannah
    Sir pl make video on expansion tank system

    • @TanweerAhmed
      @TanweerAhmed  4 месяца назад

      Thank you for your kind words

  • @farooqakash6874
    @farooqakash6874 2 месяца назад +1

    Sir please make video on system selection. Like for different buildings, which type of system should be installed. No such information are available on RUclips...

  • @jamilkhan1810
    @jamilkhan1810 2 месяца назад +1

    Assalam alaikum tanveer bhai

  • @abidmehmoodawan855
    @abidmehmoodawan855 2 месяца назад +1

    AOA sir. Thanks for sharing great knowledge. Sir Site Engineer agar banena ho tu HVAC Contractor ke sath Kam karna hota ha ya HVAC consultancy ke sath ?

    • @TanweerAhmed
      @TanweerAhmed  2 месяца назад

      Site Engineer may be representative of consultant, client or contractor

  • @Routinelifevlogs
    @Routinelifevlogs 4 месяца назад +1

    Aslmwlkm sir
    Pls make a video on FHC(Stand pipe-1 , Stand pipe-2 and 3) How to use and remove hose pipe semi automatic and automatic

    • @TanweerAhmed
      @TanweerAhmed  4 месяца назад +1

      W.Salam,
      My videos are available on standpipe system working, testing and operation, design pressure and design flow, fire hose cabinet, fire hose reel etc. if you want to know any specific information about this topic then let me know, as I work for preparation accordingly

    • @Routinelifevlogs
      @Routinelifevlogs 4 месяца назад +1

      I know sir and I am already watch that video but we complete understand when Live demonstration for this

    • @TanweerAhmed
      @TanweerAhmed  4 месяца назад

      @@Routinelifevlogs Ok noted

  • @gramathara4907
    @gramathara4907 3 месяца назад +1

    Can we use duration of operation as per Nfpa to calculate the water demant

  • @nigamsahu9995
    @nigamsahu9995 18 дней назад +1

    Good evening
    Could you share,me bro coverage area of the deluge valve ?

  • @zaheerulislam709
    @zaheerulislam709 3 месяца назад +1

    Kindly sir make videos on head calculation on booster pump of domestic water on building

  • @diyarymuhammed4183
    @diyarymuhammed4183 14 дней назад +2

    al salam alaikum
    how can i Eamil you sir

    • @TanweerAhmed
      @TanweerAhmed  13 дней назад +1

      W.salam,
      etanweersethar@gmail.com

  • @RajabAli-nd8ln
    @RajabAli-nd8ln Месяц назад

    Asslam O Alikum Tanveer Bhai. Bhai Please AutoCAD Or Revit MEP Py Full Course Banein Desiging Sy Ly K Installation Tk Please. Ager Apki Nazar Ma Koi Best Institue Ha Tu Wo Recommend Kr Dyein Ma Construction Side Py MEP Work Ki Desiging Or Installation Seekhny K Liya Bht Interested Hu. I Completed My Bachelor In Electrical Engineer.

  • @EnlightenEmbraceTV
    @EnlightenEmbraceTV 25 дней назад +1

    AoA Sir maine bsc mechanical engineering technology ki hui hai or DAE mechanical (power) kiya hua hai... Kia MEP ya oil and gas mein job mil sakti?

  • @pksharma7457
    @pksharma7457 4 месяца назад +1

    Nice sir

  • @hashirinarabworld
    @hashirinarabworld 2 месяца назад +1

    but this is for a building for a process area there must be different criteria

  • @MdAkhtar-oh1gs
    @MdAkhtar-oh1gs 4 месяца назад +1

    Assalamualaikum sir,Ye formula buildings ya mall k liye kaise consider krenge??

    • @TanweerAhmed
      @TanweerAhmed  4 месяца назад

      W.Salam,
      These formulae will not be used for buildings or malls.

    • @MdAkhtar-oh1gs
      @MdAkhtar-oh1gs 4 месяца назад +1

      @@TanweerAhmed Thank you sir,Plase Make videon for design of outdoor fire hydrant for yard or camp.

    • @TanweerAhmed
      @TanweerAhmed  4 месяца назад

      @@MdAkhtar-oh1gs Insha'Allah I will work on this topic

  • @amirzia5391
    @amirzia5391 4 месяца назад +1

    Assalamualaikum heat load calculation ki b video banaye thanks

    • @TanweerAhmed
      @TanweerAhmed  4 месяца назад

      W.Salam,
      HAP software videos are available on my channel. If any thing else wants then let me know.

  • @manishakumari-gu8zg
    @manishakumari-gu8zg 4 месяца назад +1

    sir aap fire spinkler aur hydrent ka bhi vedio bana dijye

    • @TanweerAhmed
      @TanweerAhmed  4 месяца назад

      My videos are available on those topics. What do you want to know?

  • @jamilkhan1810
    @jamilkhan1810 2 месяца назад +1

    Hvac site engineer ka job vacancy hai kya 4 years experience h aapse bahut pahle baat huwa tha job regarding ke bare me us time experience nhi tha av experience h

  • @AhsanIshtiaq-jt8vw
    @AhsanIshtiaq-jt8vw 3 месяца назад +1

    Salam sir g .... sir mai nay matric keya hay mujy bi agay study karna plz guide me

    • @TanweerAhmed
      @TanweerAhmed  2 месяца назад

      W.Salam, get admission in pre-engineering in FSc after matric

  • @VinodVerma-ho5or
    @VinodVerma-ho5or 2 месяца назад +1

    Sir VAM Chiller ka BOQ ka launguage mil sakta hai

  • @setyopermadi2654
    @setyopermadi2654 Месяц назад

    Asalamualaimum, sir.how storage wtr Fire Tank, concrete material with height 3 m if made without upper slab[ open]..is it alliwable or not...how is ur opinion. Thank you

  • @iqbalrafi3569
    @iqbalrafi3569 24 дня назад +1

    Sir,where belongs you from?

  • @Abrardurrani1989
    @Abrardurrani1989 18 дней назад

    Sir how to select firefighting systems according to buildings

    • @TanweerAhmed
      @TanweerAhmed  15 дней назад

      You should read NFPA standards for this detail

    • @Abrardurrani1989
      @Abrardurrani1989 15 дней назад

      @@TanweerAhmed sir which NFPA standards need to read it

  • @venkatapratap258
    @venkatapratap258 Месяц назад

    Sir in my project 1970 flats each flat 5 numbers sump capacity 400 Cum
    how much Q ?

  • @currencynewstoday4126
    @currencynewstoday4126 4 месяца назад

    How to estimate number of people in specific area

    • @TanweerAhmed
      @TanweerAhmed  4 месяца назад

      You will get the information from local area authority

    • @TanweerAhmed
      @TanweerAhmed  4 месяца назад

      According to information gather from local area authority

    • @Afsalali-xt6kx
      @Afsalali-xt6kx 4 месяца назад

      you can find out the no.of people from IBC, NFPA 101 codes. i saw a video related to this. it was very helpful. ruclips.net/video/QEJYk_upjsQ/видео.htmlsi=jEzXh2IRIVPKxP2l

  • @vijaybajaj401
    @vijaybajaj401 4 месяца назад

    Without watching like

    • @TanweerAhmed
      @TanweerAhmed  4 месяца назад +1

      No need like without watching. If you want to get benefits then must watch the video.

    • @MuhammadHussain-bs4do
      @MuhammadHussain-bs4do 3 месяца назад

      I watch your video for gain experience ​@@TanweerAhmed