Allen Bradley Micrologix 1200 Default Comm DF1 Upload

Поделиться
HTML-код
  • Опубликовано: 22 окт 2024

Комментарии • 6

  • @juanpablogalvan6112
    @juanpablogalvan6112 11 месяцев назад

    Have ever you tried with a panel view plus 600 connect df1 in RSLinx?

    • @SYPHOANG
      @SYPHOANG  11 месяцев назад

      @juanpablogalvan6112: Thank you for subscribing to my channel. You might want to check out the below video. Please let me know if you have any comments or questions.
      Allen Bradley Micrologix PLC Serial Communication with Panelview HMI DF-1 Setup
      ruclips.net/video/LmgnpFPFOs8/видео.html

  • @maicolherrera7685
    @maicolherrera7685 2 месяца назад

    Una ayuda, es que el plc el led dcom se mantiene encendido, pero el chanel 0 esta configurado diferente, que puedo hacer para que el dcom se apague y se reestablezca la comunicación, se mantienen las salidas encendidas pero no hay funcionamiento de las entradas digitales

    • @SYPHOANG
      @SYPHOANG  2 месяца назад

      @maicolherrera7685: "DCOM" means DEFAULT COM. Default Com is DF1. Once you change the Communication Protocol to anything but DF1, the DF1 light will be turned OFF. But what should be the communication protocol for the channel is the question for you. You can look into the other device that your PLC is connected to and find out what communication protocol and configuration it is looking for from your PLC. Hope that helps. Good luck

    • @maicolherrera7685
      @maicolherrera7685 2 месяца назад

      @@SYPHOANG cuando hago la descarga con la modificación del Chanel 0, el PLC me impide conectarme otra vez y por eso no me deja ponerle run

    • @SYPHOANG
      @SYPHOANG  2 месяца назад

      @maicolherrera7685: It's very simple. You pressed the button on the PLC to set the default DF1 to Channel 0, the DCOM turned ON. However channel 0 in the program you downloaded to the PLC is configured for DH485 or anything but DF1. My guess is DCOM light turned OFF after you downloaded the program to the PLC because channel 0 is now no longer set for the default DF1. You can no longer connect to the PLC because of the cable between your PLC and your computer. My guess is the cable you use is for DF1 communication protocol, it is not for the communication protocol for channel 0 in the program you downloaded to the PLC. I think that was also the reason you set the default DF1 to channel 0 on the PLC. If I was you, I would never reset channel 0 on the PLC back to DF1. My recommendation is to always find the right cable that works for the communication protocol configure in the PLC program before any downloads.
      Please consider joining my channel for more support.