  • @JUNCOSTILLASVLOG47
    @JUNCOSTILLASVLOG47 Год назад +1

    Ayos lods...

  • @gregoriotigon7066
    @gregoriotigon7066 Месяц назад

    Lods sa boss q ganyan din
    NO SHUTDOWN ALARM
    MAINS UNDER VOLT
    Maari din Kaya oil sensor yan ang problema?

  • @JesmarMondejar-ic6yp
    @JesmarMondejar-ic6yp 5 месяцев назад +2

    hard start yan boss.di aandar yan .kilangan pump ung fuel ..ganyan ang alaga ko.

    • @gregoriotigon7066
      @gregoriotigon7066 Месяц назад

      Lods pag
      NO shut down alarm
      Mains under volt
      Ano Kaya sira nya kc ginagamit PA din namin kahit may alarm na ganyan gang ngaun nag loko na sya may nakita aq sa display
      CRANK REST
      ayon on/off na sya NG kusa ayaw mag tuloy andar namamatay din andar

  • @angelosalvador1275
    @angelosalvador1275 Год назад +1

    Boss hinge lang ako ng tulong din. Hindi ko po kasi mapagana yung oil pressure sensor and temperature sensor ng CATERPILLAR na Generator set pinalitan ko po sya ng smartgen 6110 na controller.

    • @ka-basicchannel3485
      @ka-basicchannel3485  Год назад

      Sa SET Parameters menu po to activate ung input na sensors. Parameters rin Sir ung limit temperatures. Also watch na rin po ung mga Genset content po. Salamat.

  • @mcjamir
    @mcjamir 4 месяца назад +1

    Sir pwede po ba ma by pass yang oil pressure sensor para mapa gana ang genset? Cummins 6bt 5.9 engine po

    • @ka-basicchannel3485
      @ka-basicchannel3485  3 месяца назад +1

      Ecu ang nagmomonitor nyan, kung inibypass ang ang sensor na yan na wala namang anomaly ay bale wala na ang ecu para maprotektahan ang makina.

  • @manuellastrollo2168
    @manuellastrollo2168 11 месяцев назад +1

    reset lang boss. ok na yun? sana pinaandar din

    • @ka-basicchannel3485
      @ka-basicchannel3485  11 месяцев назад

      sa smartgen Hindi yan reset lang Sir. Nariyan pa rin Ang trouble. Pressure sensor ay nakakabit sa makina and or faulty pressure sensor. during the run Yan Sir makikita result and same scenario kapag ipipilit intermittent.

  • @Teammyloves15
    @Teammyloves15 Год назад +1

    Yong Genset Namin nilagyan ko ng maraming diesel pero nag alarm parin yong fuel niya ano kaya problema non

    • @ka-basicchannel3485
      @ka-basicchannel3485  Год назад

      Check paps Yung event Logs kita riyan Ang cause. Maaaring High Temp meron din po tayo contents para riyan and how to find event Logs on Genset.

    • @Teammyloves15
      @Teammyloves15 Год назад

      Salamat paps sige panoorin ko yang tutorial video mo paps maraming salamat SA idea..

    • @Teammyloves15
      @Teammyloves15 Год назад

      Ano dapat gawin pag high temperature paps?

  • @PantoEfrenJr
    @PantoEfrenJr 2 месяца назад +1

    How to reset idol?

    • @ka-basicchannel3485
      @ka-basicchannel3485  2 месяца назад

      Through smart gen intervention. And why to reset it to default?. In this type of trouble of Low Pressure, need no reset default parameters as it cause another trouble as its sensors set to stop the engine in case of anomaly on its devices been detected. 60C is alarming as overheat is possible engine related trouble. Coolant and Engine Oil must be check and basic parameters.