    @mustafaaljweijati7663 9 месяцев назад +1

    Interesting conversation, I have question do you have simpler alternative for support? seems expensive support the one in the video.

  • @zejean
    @zejean Год назад +3

    Excellent presentation!

  • @119busanovic
    @119busanovic Год назад +2

    Great experience!!

  • @Running.guy7
    @Running.guy7 Год назад +2

    great! is there a minimum required length of SBC to supported? or just support a SBC regardless of the length?

    • @neilparkinson119
      @neilparkinson119 Год назад +3

      Thanks for your comment. The answer depends on the type of SBC. For simple cantilevered SBCs like the ones I showed in the presentation, the overall length should be minimised to reduce the risk. However for SBC which connect to a fixed point or which connect between 2 different main lines, the overall length must be ‘not less than a minimum allowable length’ as specified in the EI Guidelines. This length depends on the SBC branch diameter and the type of welded fitting e.g. Weldolet. Let me know if this answers your question. Regards, Neil

    • @squigglesbawd
      @squigglesbawd Год назад +2

      @@neilparkinson119 thanks for the reply.