  • @AdamDeLay07
    @AdamDeLay07  10 месяцев назад

    Links to the parts & pieces in the video (affiliate links)
    ------------------------------------
    Adafruit Non-Latching Mini Relay FeatherWing
    www.adafruit.com/product/2895
    ELEGOO 120pcs Multicolored Dupont Wire
    amzn.to/40avHKx
    Victron 48V MultiPlus-II 5kVA 120V Inverter
    www.currentconnected.com/product/victron-48v-multiplus-2-5kva-120v-inverter-70a-charger/?ref=AzzpK9Fl
    10kVA 120/240v Base MultiPlus-II System
    www.currentconnected.com/product/10kva-120-240v-multiplus-2-5kva/?ref=AzzpK9Fl
    Victron Cerbo GX
    www.currentconnected.com/product/victron-cerbo-gx-system-controller/?ref=AzzpK9Fl
    Victron GX Touch 7" Display
    www.currentconnected.com/product/gx-touch-display-cerbo-gx/?ref=AzzpK9Fl

  • @Albert_206
    @Albert_206 10 месяцев назад

    Just a great video Adam, one gets full ideas out of enthusiasm (seriously) 👍👍 Cheers, Albert 🇳🇱

  • @cgutowski471
    @cgutowski471 10 месяцев назад

    Another great video. Seems you are getting into more automation and other topics because you’re not fighting inverter issues any longer.

    • @AdamDeLay07
      @AdamDeLay07  10 месяцев назад +1

      Thanks Chris! Yeah it’s amazing how much other stuff you can get into when your not constantly fighting issue…

  • @kamsiu7342
    @kamsiu7342 3 месяца назад

    The large Venus OS has Node Red feature where you should able use the other relays in automation

  • @DaveCapamagian
    @DaveCapamagian 5 месяцев назад

    Hi Adam, awesome video mate, very helpful to get the relays set up. Would it be possible for you to do a video on setting up analog tank level senders into the Venus OS. I just can't make sense of the info online. Cheers in advance Dave

    • @AdamDeLay07
      @AdamDeLay07  5 месяцев назад

      Thanks Dave!
      Unfortunately I don’t have any tank that I can put a sensor on. It might be worth asking some questions on the Victon community forum.
      Now I did just do a video on a Bluetooth propane sensor and from what I’ve seen, the same company might do Bluetooth water sensors as well that integrate into the Victron ecosystem. Might be worth a look (plus less wiring!).

  • @socialcycles13
    @socialcycles13 9 месяцев назад

    Adam, great videos on the Victron inverter. I would like you to do a video on ess back feeding into the grid.

    • @AdamDeLay07
      @AdamDeLay07  9 месяцев назад

      Thanks!
      I do not have an interconnection agreement with my utility company and these Victron inverters are not UL listed.
      I do plan on looking at ESS at some point, but with the attempt to not backfeed the grid at all.

  • @tiborchren
    @tiborchren 10 месяцев назад

    Thank you for this video 👍

  • @GarethJones-dk9yp
    @GarethJones-dk9yp 10 месяцев назад

    Great video. I've done this before. I still suffer with one little issue is my main circuit breaker is wired to a shunt trip on the dc side. When I reboot the pi the gpio pins go high for a couple of seconds and then low when it boots up.
    Annoying this trips my breaker. Need to find a fix for this at some point.

    • @AdamDeLay07
      @AdamDeLay07  10 месяцев назад

      Thanks! That's interesting. What shunt trip breaker are you using?

  • @fpvtechnology837
    @fpvtechnology837 5 месяцев назад

    Hi. I cannot find video where you explain how to install packages manager ?
    Franck from France

    • @AdamDeLay07
      @AdamDeLay07  5 месяцев назад

      Howdy Franck. I believe this is one of the videos where installed SetupHelper which gives you the package manager.
      ruclips.net/video/RVkTFtDDvfQ/видео.html

  • @OurHome-lw3jz
    @OurHome-lw3jz 2 месяца назад

    Can these relays be used for alarm states on the batteries and network devices?

    • @AdamDeLay07
      @AdamDeLay07  2 месяца назад

      Unfortunately only Relay 1 has an "Alarm" function. The remaining relays all seem to be manual relays only.
      If the battery is connected to the Cerbo, it might be possible to trigger an alarm based on certain battery criteria, but I'm not positive. I haven't done much with the alarms. I've got notification set up on the Cerbo and VRM for specific instances.

  • @YamahaYZFR6RJ05
    @YamahaYZFR6RJ05 8 месяцев назад

    Amazing video! Thank you so much, this helped me a lot. I´m planning to run the new GUI-2 (which looks just awesome) in the future in my camper. Would it still be possible to have all 6 relays working after upgrading to GUI-2? I read somewhere, that GUI Mods will not work with the new version and that Kevin is not planning to continue his work on the GUI Mods.
    Cheers from Germany

    • @AdamDeLay07
      @AdamDeLay07  8 месяцев назад

      Thanks! Appreciate the comment!
      I hadn't heard about GUI-2. Looks like it's gonna be the next UI update for Venus OS. Looking forward to taking a look at it!
      I would imagine if the new update has a lot of the things Kevin put in GuiMods, there's really no need to update it.
      To my knowledge, the functionality has always been there, GUI Mods just made it accessible through the dashboard. Ultimately it's going to be based on if the controls are added to GUI-2 or not.
      Take care!

    • @YamahaYZFR6RJ05
      @YamahaYZFR6RJ05 8 месяцев назад

      @@AdamDeLay07 thank you for your answer.
      My camper is stored away at my dads place for the winter so I can't test it myself for the next 2-3 month. Maybe it would be a good video idea to check this out. 😁

    • @AdamDeLay07
      @AdamDeLay07  8 месяцев назад +1

      @@YamahaYZFR6RJ05 Now that I know it's there, I might add it to my list. I'll have to take a look first at what's currently unsupported.

  • @Paul_______
    @Paul_______ 10 месяцев назад

    How do I reverse a relay? When my switch in the screen is off the relay is on. Only relay 1 lets me change normally open or closed. Other 4 relays don't have the option in the screen. I've been trying to figure this out all day

    • @AdamDeLay07
      @AdamDeLay07  10 месяцев назад

      You just have to switch the wires around on the relay from normally closed to normally open or visa versa.

    • @Paul_______
      @Paul_______ 10 месяцев назад

      @AdamDeLay07 I wasn't sure if there would be an issue with the pi constantly energizing the relay for months if I did that

    • @AdamDeLay07
      @AdamDeLay07  10 месяцев назад

      @@Paul_______ I would just verify with the specific relay you end up using. My use cases always had the relay off until I needed to trigger something, which was always a short trigger.

    • @Paul_______
      @Paul_______ 10 месяцев назад

      @AdamDeLay07 that's it. Turns out my relay is low active so the relay is on when it has no signal. Looks like I need an active in high relay

  • @pulith5220
    @pulith5220 7 месяцев назад

    Wow thanks for this great help. I am going to order raspberry expansion 8ch board. Hope it would work.

    • @AdamDeLay07
      @AdamDeLay07  7 месяцев назад +1

      Good luck and have fun!

    • @pulith5220
      @pulith5220 7 месяцев назад

      @@AdamDeLay07 hi Adam. I tried to program using the assistant like you did without pulling wires since am awaiting for the hat for raspi. The problem is the inverter works fine as along as the mk3 cable is connected. It don't pull power from the grid but as soon as I pull out the mk3 cable it uses the grid.

    • @AdamDeLay07
      @AdamDeLay07  7 месяцев назад

      @@pulith5220 are you using any other assistants? If not, you could try using the Virtual Switch option.

    • @pulith5220
      @pulith5220 7 месяцев назад +1

      @@AdamDeLay07 no I am not using any other assistance. Let me check VS

    • @pulith5220
      @pulith5220 7 месяцев назад

      Can I pick your mind abit. The below is how I put the settings for assistant
      Program relay
      Use general flag
      Set relay ON
      When SOC lower than 15%
      Program relay 2
      Use general flag
      Set relay off
      When soc higher than 50%
      General flag
      Use general flag to ignore ac
      It's keeps charging. I tried stopping my batteries from discharging to see if the inverters would on from grid it didn't. Am I missing something here. I think when I off discharge from bms the inverter was on Inverting and not on ON. because as soon as I put to ON it tries to charge my batteries.