VLSI - STA - Graph Based Analysis vs Path Based Analysis

Поделиться
HTML-код
  • Опубликовано: 5 ноя 2024

Комментарии • 9

  • @vlsideepdive
    @vlsideepdive  2 года назад

    Full course here - vlsideepdive.com/basics-of-sta-and-timing-constraints-webinar/

  • @truptichauhan3634
    @truptichauhan3634 2 года назад +1

    Well explained

  • @hramtekkar
    @hramtekkar Год назад

    are there any tool which perform GBA? I assumed all tools perform PBA only.

    • @vlsideepdive
      @vlsideepdive  Год назад

      Well default analysis of most tools is GBA

  • @Aravindkalvakolu
    @Aravindkalvakolu Год назад

    what if timing is not met in PBA too

    • @vlsideepdive
      @vlsideepdive  Год назад +1

      Then you to fix the path to meet timing depending upon whether setup violation or hold violation

    • @Aravindkalvakolu
      @Aravindkalvakolu Год назад

      @@vlsideepdive after placement also will check timing in that case which analysis will use?

    • @vlsideepdive
      @vlsideepdive  Год назад +2

      @@Aravindkalvakolu Typically its a matter of runtime. By default you will do normal timing and then PBA for paths you are not able to meet timing. But now a days some of the tools are fast enough to run PBA by default