18 High Pressure Fuel Pump Operation

Поделиться
HTML-код
  • Опубликовано: 18 ноя 2024

Комментарии • 27

  • @justiceifeanyi5420
    @justiceifeanyi5420 Год назад +2

    Is the high pressure pump saving as the injection nozzle

  • @jussipitkonen2713
    @jussipitkonen2713 Месяц назад

    I am trouble shooting rattling noise of BMW N20 petrol engine (sounds like diesel). One potential noise source is HPFP. The engine rattling noise disappears when after acceleration or steady driving, the accelerator/gas pedal is released and comes back when the acceleratot is pressed again or car come close to stop. At the same time I can see (though OBD reader) that thefuel air mixture curve jumps up (when noise disappears) and comes back to normal range, when noise comes back..
    So I'm wondering if the rattle comes from mechanical action of piston against eccentric, and then when the accelerator is released and noise disappears, does the piston stay up and do not follow the eccentric (no mechanical contact, no noise)?

  • @lounsburyjud
    @lounsburyjud Год назад +1

    Can you think of circumstance that the hpfp would deliver too much pressure?

  • @edusson
    @edusson 5 лет назад

    Awesome explanation. Thank you!

  • @heylookitsherbie
    @heylookitsherbie 5 лет назад +2

    Is this a positive displacement pump?

  • @edusson
    @edusson 5 лет назад

    Sorry, actually just had a curiosity question... Somehow on 1:54 you say that de-energized opens the fuel inlet. That would then actually create the max pressure on the HP circuit, isn't it? But in my GTI, they actually recommend disconnecting the voltage/control signal to the solenoid and running the car for 10 seconds before working on that part of the car (so that the pressure is low, for instance to remove the HPFP...). I.e., no voltage >> close inlet, isn't it? Am I understanding something wrong?

    • @kasimirwulf1936
      @kasimirwulf1936 5 лет назад +2

      How the solenoid works can be different for each manufacturer. What he is saying when the power to the solenoid is off the valve is open. I find that this is probably the most likely configuration.

    • @dean-gm1lg
      @dean-gm1lg 4 года назад +4

      Some fuel metering valves are open with no power and some are closed with no power you can usuely tell which is which by the way the electrical connector is fitted to the unit vertical fitting is usuely open when ignition off and an horizontal fitting is usuely shut with ignition off

    • @nefgarza6419
      @nefgarza6419 Год назад

      @@kasimirwulf1936 that makes perfect sense, so failed safe will create high pressure instead low pressure to prevent lean out in the combustion chamber

  • @infinitewisdom4557
    @infinitewisdom4557 4 года назад

    Something 'wong' here!

  • @jimbrown563
    @jimbrown563 2 года назад +3

    Incorrect explanation ........
    The job of the Solenoid is only to
    hold the Spring-Loaded Inlet-Check-Valve in the Open Position.
    As the Piston moves up in its Bore, the Fuel will be pushed
    BACKWARDS through the open Inlet-Check-Valve until the
    the exact moment when the Solenoid is turned-OFF,
    which then allows the automatic Inlet-Check-Valve to Close,
    which "traps" a certain percentage of Fuel above the Piston.
    Only this limited quantity of "trapped" Fuel will be
    pumped in to the Fuel-Rail.
    If the Solenoid remains "On" continuously,
    the HPFP will NOT generate any pressure,
    or pump ANY Fuel, Period.
    In this case, the only Fuel-Pressure in the Rails will be
    coming from the "In-Tank" Fuel-Pump,
    which is also controlled by the Computer,
    and may generate as much as ~85-psi of pressure
    on demand from the Computer.
    The HPFP simply adds to this "Base" Pressure
    when the Engine-Demand requires it.
    The Engine will Idle,
    and produce very limited Power,
    without the HPFP producing any additional Pressure.
    If the Pressure-Regulating-Solenoid fails on the HPFP,
    the Fuel-Pressure will go as high as
    the Safety-Bypass-Valve will allow,
    which varies between different Pump-Models,
    and could be as high as ~3,200-psi., and possibly higher.
    .
    .
    .

    • @ajsellas2771
      @ajsellas2771 2 года назад

      A bit confused by that though, how would the hpfp create pressure (in the case of a failed regulator) , if a hpfp does not create pressure without a pressure regulator (you said that)

    • @jimbrown563
      @jimbrown563 2 года назад +3

      @@ajsellas2771
      No , You must have misread my post .......
      If the Pressure-Regulator-Solenoid Fails,
      the High-Pressure-Fuel-Pump will create it's
      maximum possible Pressure.
      I never stated that .....
      "" does not create pressure without
      a Pressure-Regulator""
      Please read again.
      ""If the Solenoid remains "On" continuously,
      the HPFP will NOT generate any pressure,
      or pump ANY Fuel, Period.""
      "On" means the Pressure-Regulator-Solenoid is
      receiving power at that particular moment.
      "On" holds the Inlet-Valve "OPEN",
      so that the trapped Fuel can flow BACKWARDS
      out of the High-Pressure-Pump.
      .
      .
      .

    • @ajsellas2771
      @ajsellas2771 2 года назад +2

      @@jimbrown563 ohhhhh ok i get it now

    • @teluguvideomemetemplates1528
      @teluguvideomemetemplates1528 2 года назад

      there are two types of these right? one open type and other closed type .. means one opens when solenoid is activel other closes when solenoid is active

    • @jimbrown563
      @jimbrown563 2 года назад

      @@teluguvideomemetemplates1528
      There are so many different Pump designs that I can't state
      for a fact that no Pump operates differently.
      But in my opinion, this is the best and most practical method
      of controlling a HPFP.
      Therefore,
      it's highly unlikely that a Pump would be designed to
      operate in the opposite manner.