Goodman Rooftop Condenser Not Cooling - How to Test a Capacitor While System is Running

Поделиться
HTML-код
  • Опубликовано: 21 ноя 2024

Комментарии • 82

  • @karlschoen7297
    @karlschoen7297 2 года назад +3

    Not a fan of return air in the same room as the furnace with an 80%
    Like using that app after while you get used to it and can figure it out pretty easy but for new guys it's a fantastic app
    Enjoy your weekend have one for the fallen Brothers who never made it home

    • @georgesummerlin1602
      @georgesummerlin1602 2 года назад +1

      Yep illegal as hell. Probably was not inspected or return was cut in after the fact

  • @tedtenny
    @tedtenny 2 года назад

    Old HVAC engineer here trying to get into the trade believe it or not. Just got my gas license. Love your vlogs, thanks from Canada!

  • @d.ricc6421
    @d.ricc6421 2 года назад

    Mike there was a nice still shot you can grab from your video when you showed the back of you bosch shirt and the horizon of the sky in the back ground. Looked sharp as a picture showing bosch.

  • @bbizzle82
    @bbizzle82 2 года назад +2

    my outdoor unit wasn't coming on a couple days ago. there was a snake by my defrost board and he got fried. luckily the board was ok and i just reset the system.

  • @Chris_In_Texas
    @Chris_In_Texas 2 года назад +3

    All that saltwater air, makes it look like the inside of a Navian! 😁

  • @arthouston7361
    @arthouston7361 2 года назад +4

    For you new guys.... if the Aux winding opens on the fan motor, the capacitor will retain a charge, and it can put you on your a$$. So, make sure that both sections of the cap are discharged by you once the power is turned off. Also, there is a simple formula you can find online for making the uf calculation while the system is energized and running. You don't need an app. Be aware that there is one formula for 60 Hz and another for 50Hz, so if you are in the UK, check to be certain you have the correct formula.

    • @acrservicesmathewr7565
      @acrservicesmathewr7565 2 года назад

      I always discharge the capacitors and make sure power has been off for atleast 10mins before actually touching the wire leads. I feel testing with system running cant always be determined if its to low to start your fan and compressor. So this works good for PM services when systems are running correctly

    • @arthouston7361
      @arthouston7361 2 года назад +1

      @@acrservicesmathewr7565 That's right. Calculated running capacitance is for PMs, and not for no-run diagnostics.

  • @nancytelling8166
    @nancytelling8166 2 года назад +1

    Hello! We love your program! I would like to purchase one of the Bosch 22 tee shirts that you are wearing in the video and that you talked about, but I don’t see the link for that particular shirt. I see other Mikey Pipes items, but not the Bosch 22 one. Would you please send me the link to purchase that shirt? Thank you and blessings!!

  • @josefj1776
    @josefj1776 2 года назад +2

    Nice I just do the math myself amps times 2652 then divide it by voltage. We go by the 10% rule also.

  • @charlescarden6348
    @charlescarden6348 2 года назад +3

    Mikey try using the Titan HD line of capacitors. They are made in Kennesaw Ga. You won't be disappointed

    • @georgekolos5255
      @georgekolos5255 2 года назад +1

      That brand titan pro is cheap garbage. I do not stock such anymore in my truck as I'm constantly replacing them.

    • @charlescarden6348
      @charlescarden6348 2 года назад

      @@georgekolos5255 the local supply house swapped to the HD line for that reason. Such better results

    • @nowhereclose4465
      @nowhereclose4465 2 года назад

      MARS all the way!

  • @dimaslespier2688
    @dimaslespier2688 2 года назад +1

    Mikey pipes OSHA three points of contact while climbing a ladder at all times. Be safe.

  • @patmcnally6
    @patmcnally6 2 года назад

    Mike I hope you and your Family a Nice Memorial Day Weekend.

  • @nosceteipsum513
    @nosceteipsum513 2 года назад

    Appreciate all your how-to vids as of lately. Have learned quite a bit. God Bless, and Happy Memorial Day!

  • @rayleepratt6249
    @rayleepratt6249 2 года назад

    Thank you for being there for me ❣️

  • @zack9912000
    @zack9912000 2 года назад +2

    most caps are 6%, rarely do I see one for plus or minus 10%. Good video as always though

  • @tedtenny
    @tedtenny 2 года назад +2

    If the disconnect was not taken out, would the system have worked without replacing the deficient capacitor?

  • @lisaholliman6097
    @lisaholliman6097 2 года назад

    That is Flawlessness

  • @benjamintimmins1656
    @benjamintimmins1656 2 года назад +3

    Mikey I think you should of at least hooked up your guages or taken a delta t! Just some constructive criticism. Otherwise good job on the cap change!

    • @georgekolos5255
      @georgekolos5255 2 года назад

      Why hook up guages if there is no suspect reason of doing so? Boredom? Every guage hook up you do will lose some charge out of system even if stub guages.

  • @BlueDinnie
    @BlueDinnie 2 года назад

    Wow those things had a rough life 😮

  • @joelgonzalez5462
    @joelgonzalez5462 2 года назад

    Hi , is my first time seeing you video , Thank you so much , I loved it , put more videos

  • @mitchelljohnston754
    @mitchelljohnston754 2 года назад +2

    Mike I am very impressed with your videos lately, and love the content 👌

  • @lilyhamilton2630
    @lilyhamilton2630 2 года назад

    Yes, this is very good

  • @josemuniz9750
    @josemuniz9750 2 года назад +1

    Hey Mikey. That's a 13 seer 5 ton condenser!!!!

    • @Kilcrops0914
      @Kilcrops0914 2 года назад +1

      I was going to say...14 amps on a 2.5 ton compressor ummm

    • @throttlebottle5906
      @throttlebottle5906 2 года назад

      good catch, "13" = the SEER in that model number and the BTU is actually the 6 to 8th characters = "060".
      I hate when they suddenly change labeling style/type. 🤬

  • @kevinpoore5626
    @kevinpoore5626 2 года назад +2

    A good morning happy memorial Day weekend and I'm number two

  • @dianekern1040
    @dianekern1040 2 года назад

    "Perfect"

  • @lyndalawley2003
    @lyndalawley2003 2 года назад

    Thank you for inspiring me to better ❤️😍😍

  • @DiverHernandez
    @DiverHernandez 2 года назад

    what app is this hvac school ?

  • @patriciashelton9184
    @patriciashelton9184 2 года назад

    Such Post make you different from ➡️👤 others

  • @jimsergi
    @jimsergi 2 года назад

    I like the app HVAC. thanks for the info.

  • @davidfoley5817
    @davidfoley5817 2 года назад

    Happy memorial day weekend!!! Love your videos and always learning something just as simple as the app you showed up!! If I ever move to New York I’m working for you!!

  • @aliciagriffin9560
    @aliciagriffin9560 2 года назад

    You're amazing. I love This And I love you 💜

  • @fatcat-hc4pj
    @fatcat-hc4pj 2 года назад

    Good morning Mikey Pipes hope you enjoy your weekend

  • @leoreyes6157
    @leoreyes6157 2 года назад

    you good

  • @scott_meyer
    @scott_meyer 2 года назад

    Write the address of the business on the unit access panel.

  • @georgiamurray1878
    @georgiamurray1878 2 года назад

    Wõw šóò çûtê lóòk..Good♥♥

  • @rebeccacarlisle2665
    @rebeccacarlisle2665 2 года назад

    Ooowee.... very Good👏 Photo

  • @stephwaylonwells3218
    @stephwaylonwells3218 2 года назад

    👍

  • @throttlebottle5906
    @throttlebottle5906 2 года назад

    Mikey "working on the wrong system" Pipes, whoops lol 🤣

  • @doncaranci2547
    @doncaranci2547 2 года назад +2

    Morning buddy

  • @williamgildea8348
    @williamgildea8348 2 года назад

    Air filter, pressures, delta T ? Why wouldn’t you check these items?

  • @annblack8171
    @annblack8171 2 года назад

    So gorgeous and strong

  • @thefathvacguy6341
    @thefathvacguy6341 2 года назад

    Hvac school is a great ap

  • @aamirshahzad8060
    @aamirshahzad8060 2 года назад

    Its 2013 , 5 ton unit

    • @DTCM-XC
      @DTCM-XC 2 года назад

      2018, 13 seer, 5 ton

  • @adamcraig1568
    @adamcraig1568 2 года назад

    Good stuff

  • @leoreyes6157
    @leoreyes6157 2 года назад

    really nice 👌 I know you

  • @thefathvacguy6341
    @thefathvacguy6341 2 года назад +1

    Always check the system when you find a disconnect off... Had one the other day... Disconnect off and breaker off. Older lady said had no issues just yearly service. Found compressor shorted

    • @Lewdacris916
      @Lewdacris916 2 года назад

      YUP ITS OFF FOR A REASON USUALLY

  • @treborwhite
    @treborwhite 2 года назад

    On that cap you were testing it says + or - 5%

    • @realSamAndrew
      @realSamAndrew 2 года назад

      That number is only for out of the box. That's a manufacturing tolerance. After being used, you can allow 10% to still be acceptable

  • @kyndalldecker9115
    @kyndalldecker9115 2 года назад

    wow 💖

  • @dorothygoff3224
    @dorothygoff3224 2 года назад

    Attractive☺️

  • @steveblake8766
    @steveblake8766 2 года назад

    Thumbs uP

  • @edwardrodriguez430
    @edwardrodriguez430 2 года назад

    Monkey pipes love the content keep it up

  • @jaywill321
    @jaywill321 2 года назад

    $174 for a capacitor....... 2 year warranty is a nice touch lol

  • @naomihoward3928
    @naomihoward3928 2 года назад

    kisses😙😙... just for this

  • @tycobb8621
    @tycobb8621 2 года назад

    They way you’re huffing and puffing, you may want to start a work out routine that involves some life saving cardio 🤷🏼‍♂️

  • @shadowman3320
    @shadowman3320 2 года назад

    Those "capaciators" are hard to find too. 😂

    • @georgekolos5255
      @georgekolos5255 2 года назад

      They shouldn't be hard to find as they are by far #1 reason of no AC calls. Where are you located?
      You can also get on Amazon Prime next day delivery all sizes starting at $15!

    • @shadowman3320
      @shadowman3320 2 года назад

      @@georgekolos5255 I was just joking about the misspelled title. Capacitors are easy to find.

  • @SpeedDemonssk8er
    @SpeedDemonssk8er 2 года назад

    Titan caps are trash man

  • @ItsTheCostanza
    @ItsTheCostanza 2 года назад

    keep Naviens off the roof

  • @imdarkk_9200
    @imdarkk_9200 2 года назад

    275 for labor and 123 for the cap? Goddamn shit there is expensive. It would cost 60 bucks all together where I am at

    • @georgekolos5255
      @georgekolos5255 2 года назад

      Almost 400 for a 20 dollar part. And about 10 minutes possibly to replace?? Let's call it one hour!
      God bless you for the 2 yr part warranty though. I reccomend though to not buy the cheapest dual run caps you can find though. Titan pro has a higher grade made in USA one that is way more reliable. Ask your supply houses about it

    • @imdarkk_9200
      @imdarkk_9200 2 года назад

      @@PipeDoctor I am located in Cyprus. Not sure how expensive it is there but here it costs around 10 euros for the cap + 40-50 euros for labor which is pretty high considering it takes us 10? Maybe 15 minutes if you need to take down a big ladder and go on a roof. Sorry if it sounded like a hateful comment just geniuenly ment that stuff there is expensive as shit compared to my country.
      Do you mind telling me what app you use as a CRM? (Pricing, scheduling etc)

    • @nowhereclose4465
      @nowhereclose4465 2 года назад

      It costs around $300 just to get a tech to your door. Of course companies are going to charge appropriately. No one works for free or on a hair string budget. And if you do you might just suck at business

    • @imdarkk_9200
      @imdarkk_9200 2 года назад

      @@nowhereclose4465 I guess that is the difference with my country. If you are going to a big company then they won't say anything for a 100 buck charge to go there. But if you charge more than 50 for just going there you won't have any clients.