H.D. Bolt / Anchor Bolts Installation in Simple Steps

Поделиться
HTML-код
  • Опубликовано: 20 дек 2024

Комментарии • 47

  • @IsaiahOkwaro
    @IsaiahOkwaro Год назад +1

    Hello Maurice a you brother to Jared Dimba.....you soo blessed good work he is a good electrician

  • @ajayiodunayo9930
    @ajayiodunayo9930 8 месяцев назад

    This is really helpful
    Very detailed and stepwise
    Good job

  • @Mr.P539
    @Mr.P539 3 года назад +3

    as always, your channel is full of important information...thank you for sharing this.

  • @calmstorm4517
    @calmstorm4517 3 месяца назад

    Making a recreation soon. Nice and informative platform for engineers

  • @noornakiboneka5484
    @noornakiboneka5484 3 года назад +2

    This is the best so far i have seen, thank you so much.

  • @isiboraikpehae8218
    @isiboraikpehae8218 2 года назад +1

    I like the fact that there are no interruption to this videos

  • @determinationndoro6182
    @determinationndoro6182 10 месяцев назад +1

    Incomplete. There was need to show how the bolts are then made firm.. What material do you use to close up the free play? how do you apply it given the obstruction caused by the already lined column and the nuts?

  • @Spantamano-tg7tn
    @Spantamano-tg7tn 7 месяцев назад

    Труба зачем нужна была? После того как вытащили на месте щель остается это потом заполняется?

    • @MauriceDimba
      @MauriceDimba  7 месяцев назад

      Lechada

    • @Spantamano-tg7tn
      @Spantamano-tg7tn 7 месяцев назад

      @@MauriceDimba На понятном языке отвечать нельзя? А -то гугл переводчик даже не переведёт то что вы написали мне

  • @shivasagarmanigilla7677
    @shivasagarmanigilla7677 Год назад +1

    1)No RCC Stub column is provided for Boundary wall
    2) While erection of PEB steel Structure,The top column surface should be clean and leveled surface without gaps in peb structure and bolt
    Any Good work guys

  • @matrimcauthon6431
    @matrimcauthon6431 2 года назад

    This for what type of building ?

  • @emkodrpljanin6170
    @emkodrpljanin6170 Год назад

    Whats holding the bolts they are not welded, not in concrete..i don't understand..

    • @MauriceDimba
      @MauriceDimba  Год назад +2

      have a look at the bottom end of each bolt, then think of what is holding the bolt after concrete pouring. That pipe you see here, is 50mm dia. this will give the bolts enough play when installing the column, this allowance is for keeping in check the alignment of columns on each column bases. These 50mm allowance will then be grouted with cement once all the columns alignment is correct after installation. Thank you for asking,. Subscribe and keep watching for more.

    • @emkodrpljanin6170
      @emkodrpljanin6170 Год назад +1

      @@MauriceDimbaI ve seen the bottom of the bolts I also watch the other video of you explaining how it works but I still think it's not safe..I wouldn't do it like that for my self..

    • @emkodrpljanin6170
      @emkodrpljanin6170 Год назад

      But nice music..

    • @ChristianWagner888
      @ChristianWagner888 Год назад

      @@MauriceDimba So you used a 50 hollow tube and the anchor bolt is about 20 mm, this leaves about 15 mm all around the sides of the bolt to grout. What kind of grout do you use to make sure it flows all the way down to the bottom of the grout? How do you get the grout in there, as each lower nut seems to cover the openings?

  • @hrjulya
    @hrjulya 3 года назад

    Very interesting! Hello from bank of Onega lake!

    • @MauriceDimba
      @MauriceDimba  3 года назад

      Thanks for watching!

    • @romantrembakov4625
      @romantrembakov4625 2 года назад

      братан, ну привет то приветом, но ты посмотри что эти идиоты привинтили стаьные коллнны к шатающимся в полостях закладным болтам.. Это пипец..

    • @hrjulya
      @hrjulya 2 года назад

      @@romantrembakov4625 Как раз умно, поди, белые европейцы научили - болты всё равно только на растяжение работают, и не нужны большие дыры с квадратными шайбами - болт можно немного наклонить, чтобы попасть в минимальное отверстие в опорной пластине.

    • @romantrembakov4625
      @romantrembakov4625 2 года назад

      @@hrjulya Я понимаю, но тогда с низу, в бетоне, должен быть ПОДВИЖНЫЙ шарнирный узел.. А так- они просто там висят в воздухе, как сосиски на веревочке подвешенные.. В итоге не болты держут колонну, а колонно просто прикручена к болтам.)))

    • @hrjulya
      @hrjulya 2 года назад

      @@romantrembakov4625 должна быть подливка, здесь какие-то временные подкладки стоят: ruclips.net/video/F-HLtnwnZnw/видео.html

  • @engineerdude8480
    @engineerdude8480 3 года назад +1

    Welcome back!

  • @solomonbahiru9838
    @solomonbahiru9838 Год назад +1

    great job

  • @faridmahomed3339
    @faridmahomed3339 3 года назад

    Very informative video

    • @MauriceDimba
      @MauriceDimba  3 года назад +1

      So nice of you

    • @faridmahomed3339
      @faridmahomed3339 3 года назад

      @@MauriceDimba i wach all your vídeos im big fan of metallic strucrures

  • @irfantech5421
    @irfantech5421 2 месяца назад

    Good

  • @rishabhrchauhan
    @rishabhrchauhan 4 месяца назад

    Legendary vastukar infra project llp

  • @danielotieno2328
    @danielotieno2328 3 года назад +1

    Long time boss

  • @romantrembakov4625
    @romantrembakov4625 2 года назад

    Stupid job. Stupid guys .. As a result the Bolts are left into a hollow cavities after tube templates were removed. It is a new system of dancing steel columns. S.O.S.