A Comprehensive Guide to Luxpower 12kW Hybrid's Functions

Поделиться
HTML-код
  • Опубликовано: 28 дек 2024

Комментарии • 37

  • @fishboneanalysis101
    @fishboneanalysis101 Год назад

    Thank you for the intro of this inverter..

  • @brandonkanthack
    @brandonkanthack Год назад +3

    Does the 200 Amp Bypass automatically initiate under loads that have a high in-rush current then revert back to powering everything off solar/battery?

  • @samfish6938
    @samfish6938 7 месяцев назад +1

    i would use lapel mike as the building blocks some sound

  • @hollywoodj500
    @hollywoodj500 5 месяцев назад

    Thank you very much for the input, I like to know if you already done the AC coupling? If you did how did you set it up?

  • @lorincapson7720
    @lorincapson7720 6 месяцев назад

    Just bought the EG4 branded version. I don't expect much difference other than the label. Sounds like a very nice inverter.

    • @tule-hz5mj
      @tule-hz5mj 3 месяца назад

      EG4 vs SolArk vs Luxpower, the most popular DIY sofar.

  • @moshtaraf3266
    @moshtaraf3266 3 месяца назад

    20:34‏ ladayna jihaz 12 kilu min nafs alsharkih walakin la yadeam bataariaat lithyum min sharikat liutsh limadhil

  • @yoshiofar
    @yoshiofar 3 месяца назад

    How do I set solar as priority, recently connected the grid to the inverter, now when the grid on, all I see on the screen is solar to battery and grid to house

  • @sneakypete830
    @sneakypete830 Год назад

    Very interesting inverter, i currently have 48 panels all using enphase iQ7 micro inverters, you said i could keep those micros and connect line 1 & 2 to the generator ports?? Very very interesting

  • @mars617
    @mars617 Год назад

    can this inverter be black started? in other words if during grid down, yur batteries from below say 10% and shut down . How do you restart if still only AC coupled or with PV?

  • @BuildingHisHouse
    @BuildingHisHouse 8 месяцев назад

    What did you mean that the 200 amp pass through allowed you to “cut down on the use of a sub panel”? Could you explain that in detail? I’m just guessing, but does that mean that you are not backfeeding a panel with solar and a backfeed breaker, or are you talking about something different?

  • @bravotwozero535
    @bravotwozero535 8 месяцев назад

    Looking at the manual, it seems very intuitive and very flexible. I like that all the safety disconnects are included. I would probably still wire an external grid meter to main panel bypass in case the unit fails.

  • @llfrater19
    @llfrater19 5 месяцев назад

    How does it compare to growatt ?

  • @rsmiele
    @rsmiele Год назад +5

    Is this the same as the EG4 18K? Who else sells this inverter in the US? Thanks

    • @lightdepsolutionssolutions4099
      @lightdepsolutionssolutions4099 Год назад +1

      I think it’s something in between the 6000xp and the 18k. I’m curious too!

    • @D-Khaz
      @D-Khaz Год назад +1

      Definitely not the same, but likely made by the same OEM under the same roof built to different specs. Same with SolArk.

    • @JbVest
      @JbVest Год назад +1

      The 18KPV does only have 12K output But 18Kw of PV input. This unit doesn't quite look like the 18K PV

    • @rickyrusselburgusa8644
      @rickyrusselburgusa8644 Год назад +1

      Wonder if it can 21kw of Solar like the EG4 18K?

    • @jiehuang4026
      @jiehuang4026 11 месяцев назад

      Yes. EG4 hybrid inverter from Luxpower.
      However Huayu has provided about 400 pages of new evidences to the court in China to prove that Luxpower used the same money for Huayu’s exclusive 8-10kW series models to certify the so called 12kW model(the actual AC output is 10.4kW/208V only). But Luxpower provided nothing to the court to prove they have paid another certification fee(another million CNY)for the so called fake 12kW(10.4kW/208V). Also Luxpower tried to prevent the court to obtained evidences that Luxpower has also sold Huayu’s exclusive models 8kW/10kW models to US companies(such as Fortress & Sunbeat). In this case, Huayu reserves the right to further sue Luxpower Contract Swindler Crime until Luxpower proves that they have used Huayu’s certification fee as agreed on Jan.14th, 2021 for Huayu’s exclusive 8-10kW series models, not including the fake 12kW model(10.4kW/208V).

  • @fortniegodking5776
    @fortniegodking5776 Год назад

    can this be use in nigeria

  • @alansanders6355
    @alansanders6355 Год назад

    Can this unit be used with an LiFePO4 battery bank that is not connected with communication? No one seems to answer this question. If I do not buy the computer rack Lithium Batteries, can it charge, and use the LiFePO4 battery bank?

    • @SiSoy14
      @SiSoy14 8 месяцев назад

      Sol-Ark can

  • @trevaunmiller6659
    @trevaunmiller6659 Год назад

    Where can I buy this?

  • @timboe1848
    @timboe1848 Год назад

    How much for the inverter?

  • @bearupfarm1818
    @bearupfarm1818 Год назад +1

    Is this the same as the 18k from Signiture Solar. If not how sells it?

    • @Richard-nb4iv
      @Richard-nb4iv 8 месяцев назад

      I heard that this is the EG4 inverter, only EG4 brands it and supports there own software? Something like that. They are both Lux inverters.

  • @samfish6938
    @samfish6938 7 месяцев назад

    smart port you could use it to charge car so it does not use all your battery

  • @VintageJoeStalin
    @VintageJoeStalin 9 месяцев назад +2

    Sound quality is horrendous. Narrative is mostly wordy illiterate slang… “right off the bat”, etc. Seriously. If you can’t even figure out how to create a video with decent sound quality, how do you expect anyone to think that you know anything about a solar hybrid number? I mean seriously, why even waste your time. Or ours.

    • @jamelectro962
      @jamelectro962 7 месяцев назад

      All that didn't matter to me. I understood perfectly. The video was informative and that was all I needed.

    • @ArthurDentZaphodBeeb
      @ArthurDentZaphodBeeb 3 месяца назад

      It's badly done. Crappy video/audio - amateurish as hell. Unscripted. Keeps talking about 'they' despite this supposedly being the manufacturer's channel - it should be 'we/us/our' etc. Half-assed and gives terrible impression. Nobody responds to the comment section. Red flags everywhere that says 'stay the hell away'