  • Опубликовано: 21 окт 2024
  • In case of failure, the failed generator is automatically replaced by :
    the APU generator if available
    the other main generator with automatic partial
    galley load shedding.
     In case of total loss of all main generators, the RAT is automatically extended and drives the emergency generator via a hydraulic motor.
    The EMER GEN supplies the AC ESS BUS and the DC ESS BUS via the ESS TR.
    The ECAM WD remains powered, with associated procedures presented.
    Alternate law is operative through ELAC 1 and SEC 1.

Комментарии • 7

  • @bazokazoro4563
    @bazokazoro4563 3 года назад +13

    One important thing:
    Don’t hold the test button more than 30*sec deploy solenoid could burn 😉

  • @skaibuana4115
    @skaibuana4115 4 года назад

    Does the RAT deploy or just continuity system test?

    • @bazokazoro4563
      @bazokazoro4563 3 года назад +5

      No it’s just simulation and checking the emergency system