Nitrox 6KW Complete Solar Settings | Battery Charging & Smart Load Settings ⚡️

Поделиться
HTML-код
  • Опубликовано: 9 ноя 2024

Комментарии • 169

  • @XeeshanAhmad2
    @XeeshanAhmad2 Год назад

    Informative video

  • @luqmanmayar8530
    @luqmanmayar8530 7 месяцев назад +1

    Ap ki vedio nay sub kuch samjha diya thanks brother.. bahut settings wali vedio daik li laken ye sub say achi hai ❤

  • @mysteriousstuff123
    @mysteriousstuff123 8 месяцев назад +1

    Very informative and nicely explained video

  • @IbraheamButt
    @IbraheamButt 3 месяца назад +1

    Both acha Gide Kya apny. Thanks🎉

  • @ahmedbashir5673
    @ahmedbashir5673 3 месяца назад +1

    Bohat hi umda bro

  • @omarsaeed9055
    @omarsaeed9055 10 месяцев назад

    Bhai best video available on RUclips regarding inverter setting

  • @GraceSweetspirmahal
    @GraceSweetspirmahal Год назад

    Very useful and informative Video ❤

  • @ahmadsajjad6122
    @ahmadsajjad6122 3 месяца назад +1

    Brother mera b 6kw hybrid system h with batteries, net metering abhi nae krwae but month tuk green meter install ho jae ga, tub tuk kya mai apki settings kr skta hu jo ap nay is video mae ki? Kindly guids

    • @Dailytechpk
      @Dailytechpk  3 месяца назад

      Agar apky pass nitrox ho ha to ap kar sakty hain lekin jasay main ny btaya ho ga net metering case mein sell first karty hain phr us hisab sy kejaye ga

  • @HamzaAhmadAshfaq
    @HamzaAhmadAshfaq Год назад +1

    Nice! Much awaited video, Thanks 🙏🏼

    • @Dailytechpk
      @Dailytechpk  Год назад

      Hope you enjoyed it!

    • @MuhammadUsman-zf1wr
      @MuhammadUsman-zf1wr 8 месяцев назад

      Assalamalaikum max solar power.mery pass 4 plate h 555 ki 2220 max solar power rakho?

  • @ShahnazBibi-bs3zy
    @ShahnazBibi-bs3zy 5 месяцев назад +1

    Thank you so much brother. Kindly 3kw nitrox k settings k b video banawo. Khaas kar batery setting ki.

  • @syedamirshah6401
    @syedamirshah6401 11 месяцев назад

    جزاک اللہِ خیر

  • @MuhammadJamil-zc8xr
    @MuhammadJamil-zc8xr 4 месяца назад +1

    Battery Capacity ap ne two batteries ki sum kar k likhi hea ya single battery ki capacity hi likhi hea??? app ne 2 batteries lagai hain tu dono ki capacity jama kar k likhni hea ya single ki likh dain hea????

    • @Dailytechpk
      @Dailytechpk  4 месяца назад

      Volt jama hoty hain bahi ampares same rahty hain.

  • @rafaymemon480
    @rafaymemon480 4 месяца назад +1

    Ye inverter bagair battery ka chalsakta hai jaisa offgrid chalta hai

    • @Dailytechpk
      @Dailytechpk  4 месяца назад

      Jeee chal jata ha batteries activate nae karni hoti phr

  • @alibaig4019
    @alibaig4019 2 месяца назад +1

    bhai kch smart load enter kr k check to krwaen
    what is the difference between smart load n heavy load...??

    • @Dailytechpk
      @Dailytechpk  2 месяца назад

      Ok bahi smart load and heavy load both are same

  • @SharjeelTariq-yy9cp
    @SharjeelTariq-yy9cp 3 месяца назад +1

    Best explanation

  • @bisamabbas1535
    @bisamabbas1535 Месяц назад +1

    MASHA'ALLAH JAZAKALLAH bahi

  • @asifmuhammad6641
    @asifmuhammad6641 11 месяцев назад

    Well done 💯✅ Nice Review as compared to other U Tuber

    • @Dailytechpk
      @Dailytechpk  11 месяцев назад

      Thank you so much 🙂

  • @muhammadnasir2980
    @muhammadnasir2980 2 месяца назад +1

    Kindly share the setting of nitrox 8 kw 2024 model ?

  • @asifmuhammad6641
    @asifmuhammad6641 11 месяцев назад +1

    Bhai Volt k bujaye Percentage per bhi settings ki video bunaye Please

  • @LawwithUmar708
    @LawwithUmar708 5 месяцев назад +1

    Sir kaya ap nirox 8 kw 2024 ke setting ka tarika botain gay mare Ghar ke inverter ke setting rest ho gay hai

  • @DoctorReaper007
    @DoctorReaper007 5 месяцев назад +1

    Bhai inverex 8kw 2024 model with net metering ki complete setting lazmi btain plz . Lithium battery installed

  • @shenokhan5307
    @shenokhan5307 8 месяцев назад +1

    Bhai 3 killowatt nitrox with out battery work kar sakta hay. Main kharidna chahta hon.plz reply me.

    • @Dailytechpk
      @Dailytechpk  8 месяцев назад

      Nitrox ky liay battery zarori ha bahi

  • @javidfarid986
    @javidfarid986 10 месяцев назад +1

    Aoa sir sir mera pas nitrox 3 kw hai sir aur 2 batery acid wali hain sir 130Ah ki sir ap yeh batain kh charging aur discharjing kitni honi chahyaa sir kindly mujhey reply karain sir thanks percentage main batain use battery percentage wala option ko use kartaa huaa

    • @Dailytechpk
      @Dailytechpk  10 месяцев назад

      Battery ki charging ki setting to jesay ap bata rahy hain 10A honi chahaye aur discharge current ap ko backup ky hisab sy rakhna chahye ky kitna backup chahty hain? Mtlb jitna discharge barhayien gy backup km hota jaye ga .

  • @AliShan-he8vk
    @AliShan-he8vk 6 месяцев назад +1

    Solar aur wapda sharing ka option ha?
    Matlab agar battery charged nahi hain subha subha aur solar 2 kW bana raha aur load 3 kW ha to sharing hogi, sync kar kay? Ya pura load wapda pay shift jojay ga?

    • @Dailytechpk
      @Dailytechpk  6 месяцев назад +1

      Sharing ho gi hum load first rakhien gy 😊

  • @kashanahmed4118
    @kashanahmed4118 6 месяцев назад +1

    bhai generator ki settings ka bhi kuch bata den, hamarey pass generator hai aur connection bhi kiya hai uska magar us se charging nhi horahi, hamara inverter model inverex nitrox 6kw hai

    • @Dailytechpk
      @Dailytechpk  6 месяцев назад

      Ok i will share the details insahAllah

  • @aadilhayat
    @aadilhayat 6 месяцев назад +1

    Grate vedio

  • @ahmadsheikh6441
    @ahmadsheikh6441 6 месяцев назад +1

    Very informative video

  • @dr.zeeshanmirza
    @dr.zeeshanmirza 9 месяцев назад +1

    Excellent video.kaya netrox inverter same work karta hay jasay 5kv ka normal inverter kam karta hay.jasay agar grid on na.karain to battery aur solar per day time per chalay aur raat mai sirf batteries ler chalay jasay normal.hybrid inverter kam karta hay.ya zaroori hay wapda on rahay always????

    • @Dailytechpk
      @Dailytechpk  9 месяцев назад

      Thanks .Jeee asay hi work karta ha ⚡️ grid zarori nae but agr load zaydah ho raat ky waqt to grid ki zarorat par jati ha jub batteries 🪫 khatam hn tub.

    • @dr.zeeshanmirza
      @dr.zeeshanmirza 9 месяцев назад +1

      @@Dailytechpk thanks for reply.per agar grid na ho to koee problem to nahe hogee in case battery down hojaaa?

    • @Dailytechpk
      @Dailytechpk  9 месяцев назад

      Nae problem bss yehi ho gi ky raat ky waqat battery 🪫 low hony ky baad ye output off kar dy ga subha jasay hi solar aye ga phr sy output on ho jayi gi.😊

  • @shahbazmehmood906
    @shahbazmehmood906 8 месяцев назад +1

    Kya 6 aur 7 Ki sting dual mppt men Laga sakty hy

    • @Dailytechpk
      @Dailytechpk  8 месяцев назад

      6 aur 7 sy kia mtlb ha apka?

    • @shahbazmehmood906
      @shahbazmehmood906 8 месяцев назад +1

      @@Dailytechpk 6 panels Ki sting aur 5 panel Ki sting alag say nitrox 6kw dual mppt hy

    • @Dailytechpk
      @Dailytechpk  8 месяцев назад

      Jeee laga sakty hai ln agr apky pass 11 pannels hain to ap aik sting 5 panels ki laga dien aur aik 6 panels ki .

    • @Dailytechpk
      @Dailytechpk  8 месяцев назад

      9 panels ky baad single sting nae lagani chahaye 5-6 kw inverters mein

  • @sohailahmad355
    @sohailahmad355 2 месяца назад +1

    Assalam o Alaikum
    Brother mera 6kw hybrid nitrox inverter ha
    Mera issue yeh ha, jab night mn wapda shut ho jay tu, 48 volts batteries back up on nahin hota.
    Please setting bata dain
    Jazak Allah

  • @sohaibkhan4043
    @sohaibkhan4043 6 месяцев назад +1

    Bhai net metering pr b feeding kam karta hy 16 kw production chart mn sa consumption 3 kw baqi grid feeding but in total consumption mn kwh ziyada karta hy or 45% feeding jab k consumption load 40% hota ha feeding 60%

    • @Dailytechpk
      @Dailytechpk  6 месяцев назад

      Ap kia kahna chah rahy hain ky app mein values thk nae ati ?

  • @MuhammadImran-pb5tp
    @MuhammadImran-pb5tp 6 месяцев назад +1

    Waqas bhai
    Mery pas 6kwa hybrid battery sys hy
    Net metering hy, load 1 to2 kw
    Kia bill zero ho ga ya spl manage krna ho ga
    2. Muje electrician ny dungle nh supply kia, na hi box mn hy
    Mn online krna chahata hun plz guide

    • @Dailytechpk
      @Dailytechpk  6 месяцев назад

      Brand konsa ha dongle ka phr pata chal sakta ha aur agr apka load 1-2 kw ha aur system 6kw on grid hybrid ha to definitely bill zero ho ga

  • @tomtree2336
    @tomtree2336 4 месяца назад +1

    Please make a video for 12kw hybrid Inverex Nitrox with netmetering.
    48 v total 4 adad 12v dry batteries installed 180Ah each.
    Please video for battery settings.

    • @Dailytechpk
      @Dailytechpk  4 месяца назад +1

      InsahAllah will make on it 😊

    • @tomtree2336
      @tomtree2336 4 месяца назад +1

      @Dailytechpk
      Also please make a video on how to test batteries connected in series for voltage and amps.
      I have four 12v dry batteries connected in series but don't know how to test them if all are working good or if anyone is defective.

    • @Dailytechpk
      @Dailytechpk  4 месяца назад

      Battery testing ky methods aur hain uski device ati ha ap us sy hi battery test kar sakty hain inverter individual battery info share nae karta . Thanks

  • @muhammadrashidshamim8509
    @muhammadrashidshamim8509 5 месяцев назад +1

    If 265 voltage ⚡️ is coming from grid so can we increase invertor voltage ⚡️ from 250 to 265. Please guide

    • @Dailytechpk
      @Dailytechpk  5 месяцев назад

      Yes you can but it’s not secure because our all appliances are 220 volts so maximum voltage should be around 240-250 .

  • @ahmedalisohu1283
    @ahmedalisohu1283 5 месяцев назад +1

    Inverter Nitrox main manually Equalization kase karain ? Please help

    • @Dailytechpk
      @Dailytechpk  5 месяцев назад

      Ap battery equalisation ki baat kar rahy hain?

  • @SFYN..
    @SFYN.. 4 месяца назад +1

    thanks a lot ❤

  • @hamdani84
    @hamdani84 4 месяца назад +1

    Assalam o Alaikum. Bhai Maxmimum discharge ka kia formula hy? mera 6KW ka inverex IP 65 inverter hy with 6 plates of 575watt. and 148AH ki 4 tubular batteries ek hi row mei installed hen.
    Kindly guide kr den kia setting ho gi:
    Battery Capacity?
    Max A charge?
    Max A discharge?
    Kindly ye b bta den k mera inverter hr waqt battery charging pe rakhta hy. Wapda pe ho ya solar pe. iss ka koi issue tau nhi?

    • @Dailytechpk
      @Dailytechpk  4 месяца назад

      W.salam bahi apko maximum charging current 15Ah rakhna chahye aur discharge current output load ky mutabiq rakhty hain jitna ap discharge current zaydah ho ga load zaydah chalay ga lekin battery backup km ho jaye ga

    • @Dailytechpk
      @Dailytechpk  4 месяца назад

      Battery charge hoti rahti ha lekin fully charge ky baad wo sirf 30-40 watt ly rahi hoti ha uska issue nae ha

    • @Dailytechpk
      @Dailytechpk  4 месяца назад

      Wapda na hony ki surat mein raat mein ap kitna load chalana chahty hain discharge current ki value us py depend karti ha

    • @Dailytechpk
      @Dailytechpk  4 месяца назад +1

      6kw inverter ky hisab sy daikhien to0 100ah hona chahye lekin apki plates km hain mtlb ap km load chahlaty hn gy to plates ky hisab sy 50 banta ha aur agr backup time chahye to batteries 🪫 choti lagi hain age ap ny 50ah rakha to 2.5kw ka load approximately 2-2.5 ghanty chalay ga ye sari setting customised hain according to use hain load hain battery capacity ky hisab sy hain

    • @hamdani84
      @hamdani84 4 месяца назад

      @@Dailytechpk Bhai ap k comments ka buht shukriya. Normally hamaray pas WAPDA ziyada der nhi jati kabhi kabhi 15 mint aadha ghanta jaati hy. aur WAPDA na honay ki soorat mei 2000 se 2500 watts ka load battery pe chal jaaye tau kaafi hy mujhay.
      Bhai ek bat aur pocchni thi k ap ne jo Battery setting mei Grid charge and Grid Signal ki option pe check krwaya hy aur iss k bas System Work Mode mei Time of Use wali window mei bhi Grid charge ko tick krna chahye ya aur time of use ka kia matlab hy? Please iss ko bhi thora explain kr den

  • @ajazmughal1292
    @ajazmughal1292 8 месяцев назад +1

    assalam o alaikum
    nitrox ki device kis terhan connect kartay han plzz is pay b video bana dan ap.

    • @Dailytechpk
      @Dailytechpk  8 месяцев назад

      Ok bahi zaror insahAllah

    • @ajazmughal1292
      @ajazmughal1292 7 месяцев назад

      bhai ap ki video ka intezar ha abhi tak ap nay nitrox ki device mobile connect ki vido nahe banaye.

  • @sohaibkhan4043
    @sohaibkhan4043 6 месяцев назад +1

    Bhai mera nitrox 8 kw + 8kw parallel system main f23 gfci error on master inverter mn or f41 parallel system stop on salave inverter
    What is the solution hy kindly guide

    • @Dailytechpk
      @Dailytechpk  6 месяцев назад

      Will update you shortly

  • @MuhammadZahid-w4p
    @MuhammadZahid-w4p 8 месяцев назад +1

    Very.nice

  • @syedfaizan5283
    @syedfaizan5283 6 месяцев назад +1

    Waqas Bhai maire pas problem ye aa rahi hai k din time load 2kw se uppar jata hai to inverter wapda se sharing karta hai.. Netrox 6kw inverter hai maire pas

    • @Dailytechpk
      @Dailytechpk  6 месяцев назад

      Bahi Pv kitna laga huwa ha apky?

    • @syedfaizan5283
      @syedfaizan5283 6 месяцев назад

      Bhai 580watt ki 12 plates hain

    • @syedfaizan5283
      @syedfaizan5283 6 месяцев назад

      6 6 plates ki 2 strings banai hain pv1 aur pv2 k liye

  • @haseebahsan9197
    @haseebahsan9197 6 месяцев назад +1

    Dental clinic ha 9 to 5 run krna hai total load 3.5 kw ha or battery backup 400 amp kindly settings bata den nitrox ki k kam sae kam bijli ka bill ayae

    • @Dailytechpk
      @Dailytechpk  6 месяцев назад

      400 ampare means ap ny 200 wali 2 batteries lagayien hain ?

  • @noumanshabbir1990
    @noumanshabbir1990 2 часа назад

    Sir grid settings ki settings ka password kya hy

  • @ziacompany8023
    @ziacompany8023 5 месяцев назад +1

    I am using sp-1200 (12V 90ah) four batteries with nitrox 6kw hybrid inverter
    Kindly guide me
    Battery Capacity?
    Max A charge?
    Max A discharge?
    Thanks

    • @Dailytechpk
      @Dailytechpk  5 месяцев назад

      90ah
      your maximum charge should be 10ah and
      maximum discharge current depends on batteries capacity your batteries are small set it @50-60ah

    • @Dailytechpk
      @Dailytechpk  5 месяцев назад

      According to this setting you will run appliances approximately up-to 2500-2800 watts . If you set it high your backup will be decrease.
      Thanks

    • @ziacompany8023
      @ziacompany8023 5 месяцев назад

      جی شکریہ

  • @sulemanaltaf_vlogs
    @sulemanaltaf_vlogs 2 месяца назад

    Excellent video

  • @testameer
    @testameer 10 месяцев назад +2

    price of nitrox 6kw hybrid solar invertor

  • @Adnan.rar1
    @Adnan.rar1 9 месяцев назад +1

    Apne setting m 280 ampere likha h apne 1 battery Ki capacity likhi hai ya tamam ki mila kr

    • @Dailytechpk
      @Dailytechpk  9 месяцев назад +1

      Bahi batteries series mein lagti hain volt jama hoty hain battery 🔋 Amperes same rahty hain single battery ky is inverter ko 4 batteries mtlb 48 volts supported ha

    • @Adnan.rar1
      @Adnan.rar1 9 месяцев назад +1

      @@Dailytechpk bhai meri tublar battery 185ah ki 4 hain uder 740 ampere likhe ya 185

    • @Dailytechpk
      @Dailytechpk  9 месяцев назад

      185 bahi

  • @anasabdullah1925
    @anasabdullah1925 7 месяцев назад

    Hi. Mere pass Lithium battery lagi huee Inverex ki. Smart Load ki kia setting rakhun? Mera heavy and normal load sab mix hai. Partial nahi hua wa. Abhi off 50% hai or ON 100% hai. Mai chahta hun. Mera system off na ho. Battery se cover krey or solar se cover krkey wo system khudi manage krkey chalata rahe

    • @anasabdullah1925
      @anasabdullah1925 7 месяцев назад

      Aj Subah inverter ne output dena band krdiya. Phir mainey Lithium Error Or ko on kra to output dena shuru krdiya. Or kisi kism ka error nahi aaya. Muje system lagaye hue 6 din hue hain.

    • @Dailytechpk
      @Dailytechpk  7 месяцев назад

      Ap phr heavy load ko off 20% py ly jayien aur start 95% py. Because heavy load ki battery setting karni parti otherwise solar km hony ya wapda na ho to wo load off ho jata ha

  • @ImranAli-ls4bl
    @ImranAli-ls4bl 11 месяцев назад +1

    Brother i have this fault and switches inverter off code is F56 DC_VoltLow_Fault plz help what is causing this

    • @Dailytechpk
      @Dailytechpk  11 месяцев назад

      Check batteries settings ,battery health and connectivity of cable . It occurs due to battery problem.

    • @ghulammurtaza931
      @ghulammurtaza931 9 месяцев назад +1

      ​@@Dailytechpk Bhai agr battery na ho TU phr F56 ka error kio Ata hai

    • @Dailytechpk
      @Dailytechpk  9 месяцев назад

      Inverter battery 🔋 demand karta ha isi liay usy jub sense nae hoti to wo error ahow karta ha with deep

    • @Dailytechpk
      @Dailytechpk  9 месяцев назад

      Is inverter ko running ky liay bhi 50watt ka current chahye hota ha jo batteries provide karti hain.

    • @ghulammurtaza931
      @ghulammurtaza931 9 месяцев назад

      Thanks bhai

  • @humairaghouse9824
    @humairaghouse9824 10 месяцев назад +1

    9:10

  • @nabeel_7
    @nabeel_7 5 месяцев назад +1

    Ager grid charge aur gen charge dono option band kar den tu bas Solar se charge hogi battery

    • @Dailytechpk
      @Dailytechpk  5 месяцев назад

      Jeee phr solar sy hi ho gi

  • @Nawabestate
    @Nawabestate Год назад

    Love you jni❤

  • @Muzammil12486
    @Muzammil12486 8 месяцев назад +1

    Bahi nitrox 3kva kee kia price hai

    • @Dailytechpk
      @Dailytechpk  8 месяцев назад

      Price to around 370k thi but abhi stock short ha 20 march tak expected ha

  • @muhammadfaizan5002
    @muhammadfaizan5002 11 месяцев назад +1

    Paise Kitne hai inverter k

  • @adnansohail1234
    @adnansohail1234 11 месяцев назад +1

    Price kia he 6kw inverter ki???

  • @muhammadsalman197
    @muhammadsalman197 6 месяцев назад +1

    Micro inverter output wo nh hai jo ap bta rhy hain😂😂

    • @Dailytechpk
      @Dailytechpk  6 месяцев назад

      Ok galti ho sakti ha ap bata dien phr kia correction karwa dien

    • @muhammadsalman197
      @muhammadsalman197 6 месяцев назад +1

      @@Dailytechpk micro inverter output se murad agar output line me aagy koi or ups ya inverter connect hai tw usky leye hai...k kb usey on krana hai or off krana hai

    • @Dailytechpk
      @Dailytechpk  6 месяцев назад

      Faraz karien agy inverter ha setting 53 volt ki ha to bahi wo kasay usy on kar sakta ha khair i will study this point

    • @Dailytechpk
      @Dailytechpk  6 месяцев назад

      Ap is setting ko phr review karien ☺️

  • @tomtree2336
    @tomtree2336 4 месяца назад +1

    Battery capacity 280Ah hey aor app ney max discharge 100A set kia hey, why? Ye tu app aaadhi sey bhi kam battery use kar rahey hain, phir itni large 280A battery ki zatoorat kia ti jo aap use hi nahi kar rahey.
    Mery kyal mey max discharge ko 280 key qareeb rakhain, say 250A tu app maximum battery ko use kar sakaingey jab wapda supply na ho raat ke waqt.

    • @Dailytechpk
      @Dailytechpk  4 месяца назад

      Bahi discharged current ampare ky mutabiq hota ha aur inverter ky hisab sy hota ha bahi main ny sahe btaya ha baki ap correction kar lien .

    • @tomtree2336
      @tomtree2336 4 месяца назад +1

      @Dailytechpk
      Mera 12kw ka hybrid nitrox system hey. With dry battery 180 Ah 48 v.
      4 adad batteries 12v each.
      Mey ne battery capacity 180Ah set ki hey aor max discharge bhi 180A hi set ki hey. Iss tarah mey battery ko maximum use kar sakta hoon agar raat ko wapda ki loadshedding 10 ghantey hi kiyoon na ho.

    • @Dailytechpk
      @Dailytechpk  4 месяца назад +1

      12kw nitrox ky liay ye setting thk ha but meri video 6kw ki ha main ny us hisab sy hi info share ki ha . :)

    • @tomtree2336
      @tomtree2336 4 месяца назад +1

      @@Dailytechpk
      Thanks 😊

    • @Dailytechpk
      @Dailytechpk  4 месяца назад

      @@tomtree2336 welcome

  • @Imrankhan-in8qu
    @Imrankhan-in8qu 6 месяцев назад +1

    وقاص بھائی ہمارے پاس دو ماڈل ایسے لگے ہوئے ہیں ہمارے ساتھ یہ مسئلہ پیش ا رہا ہے کہ ہم کبھی اس کو اف کرنا چاہیں تو جب ہم اسکاف کا بٹن دباتے ہیں تو یہ بلاسٹ کر جاتا ہے ہمارے ساتھ دو مرتبہ ایسا واقعہ پیش ایا ہے ایسا کیوں ہوتا ہے اس بارے میں گائیڈ کر دیں حالانکہ ہم پی وی کو بھی پہلے اف کر دیتے ہیں پھر بھی یہ بلاسٹ کر جاتا ہے

    • @Dailytechpk
      @Dailytechpk  6 месяцев назад

      Bahi ye technical issue ha inverter mein kindly check at inverex warranty centre ☺️

  • @shafaqat1886
    @shafaqat1886 8 месяцев назад +2

    انورس کمپنی کا سولر انورٹر انتہائی گھٹیا ترین ہے اس کو لوگ نہ خریدیں نہیں تو بعد میں روئیں گے

    • @Dailytechpk
      @Dailytechpk  8 месяцев назад

      Zarori nae bahi inverter hi kharab ho khair apka apna experience ha we honour your feedback.

    • @haroonafridi987
      @haroonafridi987 7 месяцев назад

      میرے ساتھ بھی یہی معاملہ ہوا ہے۔

  • @haroonafridi987
    @haroonafridi987 7 месяцев назад +1

    یہی انورٹر میں نے لگایا ہے مگر پورے چھ مہینے کے بعد 4 بیٹریاں خراب ہوئی۔اور تبدیل ہونے کے بعد اب ایک مہینہ کے بعد ایک بیٹری میں9 لو ووٹ پر اگیا۔کیا یہ انورٹر میں فرق تو نہیں ہے ۔
    میں نے اپ کے سیٹنک کے مطابق لگایا ہے۔بیٹری 230 فونیکس والی تھی۔پہلی بار

    • @Dailytechpk
      @Dailytechpk  7 месяцев назад

      Apki setting same asy hi thien ? Batteries bhi market mein thk nae ati tubular battery hameesha date of manufacture daikh kar lien kuenky ye company sy tayar ati ha . Inverter ka issue ho sakta ha kuen ky setting karny sy agr inverter wesay work nae karta to batteries kharab ho sakti hain

  • @zulfiqaralirana183
    @zulfiqaralirana183 7 месяцев назад +1

    وقاص بھائی میرا مسئلہ یہ ھے کہ دن میں جب خرچ کم ھو اور جنریشن زیادہ ھو تو ایکسپورٹ شروع ھو جاتی ھے اور بجائے فائدے کے نقصان شروع ہو جاتا ھے ۔کیونکہ واپڈا کا میٹر ایکسپورٹ نہیں کررہا ھوتا۔ اور میٹر ریڈنگ بڑھتی ھے۔

    • @Dailytechpk
      @Dailytechpk  7 месяцев назад

      Inveter konsa ha apky pass? Nitrox hi ha ?

    • @Dailytechpk
      @Dailytechpk  7 месяцев назад

      Agr net metering na ho to grid feeding ko off karty hain

    • @zulfiqaralirana183
      @zulfiqaralirana183 7 месяцев назад +1

      جی انوریکس نائٹروکس 6کلو واٹ ھے۔
      اور نیٹ میٹرنگ نہیں ھے۔4 بیٹری ٹیوبلر 180 ایمپائر کی ھیں

    • @Dailytechpk
      @Dailytechpk  7 месяцев назад

      Ap ny ye video pori daikhi ho gi hopefully ap sirf batteries ki charging 20A sy rakhien baki sari settings yehi karien insahAllah issue nae aye ga

    • @zulfiqaralirana183
      @zulfiqaralirana183 7 месяцев назад +1

      Your guidance is required,regarding setting

  • @omarsaeed9055
    @omarsaeed9055 10 месяцев назад +1

    Slam bhai, ap apna whatsapp number share kr skty hn, thori information chahiye apse plz