Back At That HIU, Did I Fix It This Time? - A Day In The Life Of A Gas Engineer 177

Поделиться
HTML-код
  • Опубликовано: 8 ноя 2024

Комментарии • 31

  • @cputilitysolutions
    @cputilitysolutions  Месяц назад +2

    What do you think of the first person view on this one? I'm starting to do more like this so I hope you enjoy it! Please don't forget to LIKE & SUBSCRIBE 🙏🏾

  • @bluebulldog_uk
    @bluebulldog_uk Месяц назад

    The Main boiler brings back some memories…at BG we would replace everything, seals, burner, gaskets, flue seals…even the air box if they was under contract 😢😅. On The HIU mate I could feel your disappointment! Hopefully get to the bottom of it 👊👍

  • @colin4685
    @colin4685 Месяц назад +1

    Good old potterton SL. Burner tray cracked and melted a hole in the back? 😂

  • @russellbaldry5095
    @russellbaldry5095 Месяц назад +1

    I dropped my 3 to primary school everyday and it means a lot to your kids to not put them before work 👍🏼👊🏼 was a bit tricky getting 3 on the 2 seat passenger side and wrap the seat belt over🤦🏼‍♂️😂

    • @cputilitysolutions
      @cputilitysolutions  Месяц назад +2

      I can imagine mate, defo won't get these times back 🙏🏾

  • @happybunny7490
    @happybunny7490 Месяц назад +2

    That leaking inside the boiler is a heat exchanger leaking wet side not the dry ( Co ) side , very common on those boilers mate , also boiler could have been kept on as plenty have historic signs on leakage but stop on there own . But the boiler needed replacing anyway.

    • @cputilitysolutions
      @cputilitysolutions  Месяц назад +1

      @@happybunny7490 gotcha mate appreciate the advice 👊🏾

    • @joncoke8208
      @joncoke8208 Месяц назад +1

      Theres also a way to check flue integrity on that boiler too

  • @mattygeepph4115
    @mattygeepph4115 Месяц назад +1

    Hi bud top work as always had this on and it turned to be the pressure differential valve there's a diaphragm that fails inside it 👍 😊

    • @cputilitysolutions
      @cputilitysolutions  Месяц назад +1

      Thanks mate, is that the PM valve you're referring to?

    • @mattygeepph4115
      @mattygeepph4115 Месяц назад

      Yes mate it's the proportional flow controller is it made by melbiec or oventrop bud 😉 👍😎👍😎👍😎👍😎👍

  • @stovesellers
    @stovesellers Месяц назад +2

    FPV worked well on this one. Everything in view. As for the video it's another cliffhanger!

  • @joncoke8208
    @joncoke8208 Месяц назад +1

    Looking jacked in the vest mate

    • @cputilitysolutions
      @cputilitysolutions  Месяц назад +1

      @@joncoke8208 haha cheers mate, was pumped from the hot weather! 😄

  • @cliveramsbotty6077
    @cliveramsbotty6077 Месяц назад +1

    get your commercial ticket mate you've got the brain for it

  • @Heatking
    @Heatking Месяц назад +1

    Feel for you on that HIU mate :(

    • @cputilitysolutions
      @cputilitysolutions  Месяц назад +2

      Lucky the customer was very understanding and could see I was trying to eliminate things step by step

  • @seanmcgee5060
    @seanmcgee5060 Месяц назад +1

    It's gotta be a simple blockage somewhere, surely.... 🤔

    • @cputilitysolutions
      @cputilitysolutions  Месяц назад +1

      Definitely contained within the unit, just need to pinpoint it

  • @b1h2u3p4
    @b1h2u3p4 Месяц назад +1

    What was wrong with the first boiler in the video was it the heat exchanger leaking

  • @TARSoda
    @TARSoda Месяц назад +1

    Know it may sound like I'm trying to teach you how to suck eggs here but have you ruled out the iso valve? Had a few fail on Elson HIU's, which made me feel a right tit after I'd already changed a couple parts.

    • @cputilitysolutions
      @cputilitysolutions  Месяц назад +2

      Not at all mate, sometimes it's the simplest things that catch us out. So the reason I know it's something within the unit itself is because when I turn that blending valve to all the way cold, the water pressure comes out perfect, but as soon as I wind it back to hot the pressure diminishes. That's why I thought it might be the blending valve, but it's gotta be that PM valve now. There's nothing else left between the cold in and hot outlet 🤔

    • @TARSoda
      @TARSoda Месяц назад +1

      @@cputilitysolutions Is there a strainer valve on this HIU? And if so have you cleaned it out? Know they can wreak havoc on both flow and temperature in combi HIU's lad. Some days you wonder you ended up in such an easy job and others you're up at night in cold sweats 😂

    • @cputilitysolutions
      @cputilitysolutions  Месяц назад +2

      @@TARSoda there wasn't a strainer on the domestic circuit on this one, only on the primaries. But yeah it was getting to that point, but luckily the customer was on my side and he said he only wants me to deal with it so that took the pressure off a bit