sewage Treatment plant onboard ship||

Поделиться
HTML-код
  • Опубликовано: 24 ноя 2024
  • sewage treatment plant onboard ship
    Sewage treatment plant is used to treat the sewage and make it less harmful for the sea. Marine engineers must know the operation of the sewage plant before using the same in order to comply with the rules and regulations of discarding sewage.

Комментарии • 107

  • @arsalnarker
    @arsalnarker 3 года назад +10

    Informative.
    May ALLAH bless you.
    Love from Pakistan.....

  • @PraveenKumar-gv5uy
    @PraveenKumar-gv5uy 3 года назад +14

    Really awesome bro.. you explained very well.. thanks for latest regulation on discharge condition

    • @PraveenKumar-gv5uy
      @PraveenKumar-gv5uy 3 года назад

      And bro what us your rank on-board right.. are you 2nd

  • @surajmohanty9278
    @surajmohanty9278 4 года назад +10

    SKP se acha padhate Hain sir....Love u sir ,make more videos

  • @aryanbacchuwar9918
    @aryanbacchuwar9918 6 месяцев назад +1

    respected sir your videos are very helpful to all of us sir but just one problem is the pronunciation

  • @manishrawat3534
    @manishrawat3534 7 месяцев назад +2

    great explanation

  • @tasawerashraf5190
    @tasawerashraf5190 2 года назад +1

    best teacher ever sir great explanation

  • @imranhussain1842
    @imranhussain1842 2 года назад +1

    Very nice exoanation sr

  • @ALOKKUMAR-om4gp
    @ALOKKUMAR-om4gp 2 года назад +1

    It's really Awesome video sir • keep it up•

  • @vaibhavmathur1993
    @vaibhavmathur1993 2 года назад +2

    Happy Guru Purnima Sir

  • @altamashbhore3990
    @altamashbhore3990 2 года назад +1

    Mind-blowing explaining!!!!

  • @latafatali6787
    @latafatali6787 3 года назад +1

    Really are doing excellent work ...keep it up , well done

    • @searainly
      @searainly  3 года назад

      Thank you! & Welcome brother.

  • @siddharthkumar7011
    @siddharthkumar7011 2 года назад +1

    great work sir..

  • @alfaysal4750
    @alfaysal4750 2 года назад +1

    Nice sir

  • @aligoharmughal4952
    @aligoharmughal4952 3 года назад +1

    Very Well explained Sir.

  • @haiderrizvi3509
    @haiderrizvi3509 3 года назад +2

    sir you taught it very well......tysm...!!

  • @abelpena4449
    @abelpena4449 3 года назад

    Dear Sir actually u explain very wel and very clear, but unfortunally I could not understood nothing because u are explained it in ur native language.
    So, I would like that u explaining also in english.

  • @hiteshranglani5666
    @hiteshranglani5666 3 года назад +1

    very informative.

  • @BillionBrothervlogs
    @BillionBrothervlogs 3 года назад +1

    vry informative video please can u make a video on the mainatanance carried on sewage treatment plant and the safety measures to be followed while working on this plant.

  • @msgulss2121786
    @msgulss2121786 3 года назад +1

    you are great sir, Stay Blessed Fore ever ...

  • @akshatdobhal9028
    @akshatdobhal9028 3 года назад +2

    Very informative video sir👍🏻 learnt a lot thank you

  • @newkleus7106
    @newkleus7106 3 года назад +1

    Great👏

  • @vaibhavmathur1993
    @vaibhavmathur1993 2 года назад +1

    Thank you Sir for the wonderful explanation.

  • @chandrashekharkomara9891
    @chandrashekharkomara9891 3 года назад

    Very well explained sir

  • @mithaleshkumar2486
    @mithaleshkumar2486 4 года назад +2

    So thank you sir

  • @abhishektalajiya1987
    @abhishektalajiya1987 3 года назад +1

    Very nicely explained 👍

  • @jayantgiri7920
    @jayantgiri7920 2 года назад +1

    👌👌👌👌

  • @mithaleshkumar2486
    @mithaleshkumar2486 4 года назад +1

    Blessing you God.......

  • @Adarshvrm23
    @Adarshvrm23 Год назад +1

    Incredible ❤

  • @mohammadmoktaruzzaman4165
    @mohammadmoktaruzzaman4165 3 года назад

    Nice explanation. Sir why foam coming out from vent.

  • @Sandeep-je6wu
    @Sandeep-je6wu Год назад +1

    Thank you so much sir.

  • @thakurakash7
    @thakurakash7 3 года назад +1

    thankew bhai ksm se samjh mai aa gya Thankew Bhai ...

  • @ritikbhayana1303
    @ritikbhayana1303 3 года назад +1

    Amazing sir .Really helped a lot

  • @esakkiraja548
    @esakkiraja548 2 года назад +1

    You’re are great ❤sir I love you

  • @ankitanandvlogs
    @ankitanandvlogs 2 года назад

    Hello sir, thanks for this video. Sir my ship was 2000 built gas tanker. Here these 3 chamber has common line which is connected to overboard pump. Now on our ship we had also sea water line connection to this common line to backflush. However, at some time, we used to open STP, and manually clean, later fill again with sea water, open all the valves,, start blower. when it reaches certain level, air bubbles with water can be seen in inspection pipe during operation.

  • @animalsdocumentary6600
    @animalsdocumentary6600 2 года назад +1

    Thank you sir

  • @karunmonnappa467
    @karunmonnappa467 2 года назад +1

    Sir if activated sludge is removed from settling tank with venturi effect isn't there a greater possibility that the nozzle could be blocked by sludge..?

  • @SurajCMathew
    @SurajCMathew 2 года назад +1

    ❤️❤️❤️

  • @sugarspicesatya
    @sugarspicesatya 4 года назад +1

    Nicely Explained. Can you please share the block diagram as well. TIA

    • @searainly
      @searainly  4 года назад

      Sure! soon will provide link for the same.Thankyou.

  • @DIXITAGGARWAL93
    @DIXITAGGARWAL93 3 года назад +3

    Many new ships uses sea water or fresh water for back flushing instead of grey water .

    • @searainly
      @searainly  3 года назад +1

      Dear Dixit. Thank you for giving us such a good information. Please always take part in discussions. Thank you.

    • @soumikchatterjee9223
      @soumikchatterjee9223 Год назад

      Can you please explain the process of back flushing using sea water?

  • @umasingh4187
    @umasingh4187 Год назад

    Back flush bhi describe kar do sir

  • @Sahil-sz3dp
    @Sahil-sz3dp 3 года назад

    Is the blowers are runs continuously or cut out cut in is there and why?

  • @arshkapadi6689
    @arshkapadi6689 4 года назад +1

    Thank you, Sir

  • @Sachinsharma-hb3py
    @Sachinsharma-hb3py 3 года назад +1

    thank you so much sir

  • @homegrown1444
    @homegrown1444 3 года назад

    And anthour question what steps to be adopted when we are running out of chemical during sailing

  • @sohamadhya3969
    @sohamadhya3969 2 года назад

    what should be the pressure of this grey water and how the grey water will pass from sterilization tank to the other tanks for flushing

  • @SubhodeepPramanik
    @SubhodeepPramanik 3 года назад

    thanks sir

  • @karanjans
    @karanjans 3 года назад

    Sir which device is used for measuring BOD 25mg/L.? Kaisa pata chalega
    Please also explain Aerobic and An aerobic chemical reactions also

  • @homegrown1444
    @homegrown1444 3 года назад

    Sir one important question please reply asp que - what is procedure adpoted when STP is out of order on borad ship?

  • @akashverma9272
    @akashverma9272 2 года назад

    Dangers while opening biological stp for repairs? How to minimise the risk

  • @AMANKUMAR-iz6jf
    @AMANKUMAR-iz6jf 4 года назад +1

    Sir 2 questions-
    1)If blower fails,action ??
    2)If discharge color is grey,reason and action?.
    Sir short mai hi bata dijiyega.

    • @searainly
      @searainly  4 года назад +1

      There is standby blower if one blower fails second blower comes..
      The requirement of blower here to supply air to the chamber to allow the aerobic reaction if air is not supplied then anaerobic reaction takes place inside the chamber and hydrogen sulphide' gases are released that cause marine pollution.

    • @searainly
      @searainly  4 года назад +2

      Grey water is generally cooking and cleaning waste

    • @AMANKUMAR-iz6jf
      @AMANKUMAR-iz6jf 4 года назад +1

      Thank u so much sir.

  • @atikrahman6184
    @atikrahman6184 Год назад

  • @biswarupdas14
    @biswarupdas14 3 года назад +2

    Sir if grey water is used to wash out the sewage stuck at the walls of the primary tank, then why is the grey water feeded directly to the chlorination chamber,as shown in your diagram?

    • @searainly
      @searainly  3 года назад +7

      Grey water is used to wash or flush out the stuck sewage and particles from the system.
      Now come to your Question ...Please follow the path Carefully. Feed the grey water into the chlorination tank then it overflows and flows into the carbon filter wash or flush the stuck sewage particles from this chamber and then again grey water overflows into the sedimentation and primary chamber and does the same function. and in this way grey water flash out the stuck sewage and particles from the whole system and at the bottom part there is arrangement of valve. Open the valve hence all flush out water drain out.
      Analyse the flow path of grey water properly.
      Thank you!

    • @sachinchowdhary6804
      @sachinchowdhary6804 3 года назад +1

      @@searainly Hello sir....Hope you are ok..
      I have a doubt on the same thing that on my ship 1st is bulky and 2nd one is tanker we used to flush STP with sea water in our daily routine and the grey water is thrown ovbd through different pipeline and the ovbd vv is Both port and stbd side??
      Have you sailed on the ship on which grey water is used for flushing or you have read it from somewhere???please make me understand because we have seen sea water flushing not with grey water??

  • @MdHasan-iv5im
    @MdHasan-iv5im 3 года назад

    What should be checked on sewage treatment plan during watch?

  • @shyambiradar4360
    @shyambiradar4360 3 года назад

    Pr. Of blower in aeration chamber is 0.3 to 0.5 bar.
    Atmospheric pr. Is approx 1 bar.
    How does the blower making the pr. Of .3 to .5!!!!

  • @shubhguleria9226
    @shubhguleria9226 3 года назад

    Explain about airlift of activated sludge. You said its sucks air out of ventury, i doubt it is opposite. Can you clearly explain?

    • @searainly
      @searainly  3 года назад +1

      I already said activated sludge get sucked (with the help of venturing effect) and it return through returning sludge line and again mixes with incoming sludge.

  • @rishukapoor2835
    @rishukapoor2835 2 года назад

    Sir, how to control/reduce BOD and COD of sewage treatment plant. What actions can we take onboard ship?

  • @kislaymishra6846
    @kislaymishra6846 4 года назад +1

    Sir ji engine room piping layout pe ek video, please sir 🙏

    • @searainly
      @searainly  4 года назад +1

      Sure brother! MAM k part m hi cover krunga Just give me sometime. Thank you!

  • @shyambiradar4360
    @shyambiradar4360 3 года назад +1

    Sir explain about ejector in this system

  • @surajmohanty9278
    @surajmohanty9278 4 года назад +1

    Sir if possible please make on IC also

    • @searainly
      @searainly  4 года назад +1

      After completing Marine Aux M/c will make videos on main engine topics also.Dont worry.! Thankyou.

  • @deepaksaxena222
    @deepaksaxena222 3 года назад

    About stp maintenance?

  • @jahanzabbaloch234
    @jahanzabbaloch234 3 года назад

    Awlllaaa

  • @RajeshSingh-iz6uj
    @RajeshSingh-iz6uj 3 года назад

    How can I reach to you plz ?

  • @AMANKUMAR-iz6jf
    @AMANKUMAR-iz6jf 4 года назад

    Sir in this video how biological oxygen demand is confirmed as 25mg/l.ye kaise calculate karenge?

    • @searainly
      @searainly  4 года назад +3

      The effectiveness of Sewage analysed by taking 1 litre of sewage sample and incubating it for 5 consecutive days at the temperature of 20 degree Celsius with well oxygenated water.
      Now The amount of oxygen used up by the sewage in mg/l or PPM KS termed here BOD and In this case that BOD comes is 25mg/L(u have to continue with this process BOD reaches up-to 25mg/l & This new resolution value is set by MEPC.

    • @AMANKUMAR-iz6jf
      @AMANKUMAR-iz6jf 4 года назад +1

      Bahut bahut dhanyabad sir.

  • @souravnair8893
    @souravnair8893 3 года назад +1

    Sir, 25mg/ltr of what?

    • @searainly
      @searainly  3 года назад

      As per MEPC the concentration of sewage which is going to be overboard must be less than 25mg/litre .

    • @aligoharmughal4952
      @aligoharmughal4952 3 года назад

      not more than 25mg /ltr of Suspended Solids should be present In the treated Affluent that is being discharged overboard as per MEPC.

  • @yaaralbele7040
    @yaaralbele7040 3 года назад +1

    What about omnipure stp

    • @searainly
      @searainly  3 года назад +1

      OMNIPURE(Name) is the manufacturer of high quality, cost effective waste water system..Most of the Marine STP is Omnipure marine sewage system that oxidizes sewage in an electrochemical cell as well as generates sodium hypochlorite for the disinfection of the sewage streams.

    • @yaaralbele7040
      @yaaralbele7040 3 года назад +1

      @@searainly pkz make one video on that

    • @searainly
      @searainly  3 года назад

      Thank you for your response and suggestion.. Will try to upload video on this topic soon.

  • @getachanie9136
    @getachanie9136 2 года назад

    please explain it in English