STAR CCM+ Flow Manifold Demonstration

Поделиться
HTML-код
  • Опубликовано: 4 окт 2024

Комментарии • 3

  • @ibragim_on
    @ibragim_on 5 лет назад +1

    Good job!

  • @sergeianpilov5222
    @sergeianpilov5222 5 лет назад

    Good job!
    Great illustration to - why reversed flow is evil and why we should often extend outlets.
    PS How did Extract Volume result in four outlet faces - if solid part had only one named face (Outlet_Face)?

    • @AppliedCAx
      @AppliedCAx  5 лет назад +1

      The best practice recommendation for CFD is to extend your inlet and outlet ports where possible. You want to have your flows fully developed at the inlet and outlet locations of your region of interest, otherwise you are forcing values (pressures, velocities, etc..) at those cell faces.
      Yes, there was only one face for the outlet, but there were 4 curves referenced to split the outlet face into 4 separate faces.
      Thanks for viewing!