Yesterday memu onida 1.5 ton 3 star inverter ac biginchamu.. Ac install chese vellu ok.. Parledhu. Bagane bigincharu.... 😍 ac konalani 4 years ga anukuntunnam.. Finally happy
we installed lloyd AC 1.5 ton 3 star 1 year ago in my home. Still in very good service and condition. No issue! But my preference is always LG 5 star but LG AC are way more costly.
@@jaibalodi4344Panasonic is best for home.. I am using Panasonic matter enabled smart ac.. heavy duty and very fast cooling.. however Daikin is also good.. but missing convertible modes.. Daikin and Panasonic both are example of Japanese engineering 🔥 and the best commercial purpose acs are Mitsubishi and general.. these are too much costly..
How is the Ac running now? After the delivery of the ac , how many days does it take for the installation guy to come and install it? And for that hole I guess the Core cutting drill would have been nicer!
Outdoor k pipe par tap ki insulation honi chaye? Main ny jis sy install karaaya os ny tap nai lagai pipe par. Bolta k ap ka outdoor par dhoop nai parti es liye koe issue nai
Sir ji Mera Haier Ac 1.6ton ka h jabse vgourd ka stablizer lagaya hun tab se input 150 k niche aur output 220 ki niche rehne se Ac bahut acha cooling deta h aur agar input 160 170 se upar aur output 230 ya 240 k upar rehne se cooling dena band kar deta hai So isme Ac ka problem h ya stablizer ka
Theek installation hua hai, but vacuum ke time bahut badi gadbadi kar di technician ne. Gas release karne se pahle vacuum pump ka pipe nhi nikalna chahiye. Otherwise air phir se ander chali jati hai. Joki aapke case mein hua hoga. Proper process ye hai, vacuum pump chalao, complete hone pe pahle manifold gauge ka valve band karo, phir vacuum pump band karo, 10 min wait karo, if manifold ki sui still rahti hai then compressor se thoda sa gas release karo, soap water se leakage check karo, if no leaking, then poora gas release kar do, only after this vacuum pump ko pipe machine se nikalo. Eysa karne se gas ka pressure air ko andar nhi aane deta.
Mere ghr me kch din pehle hi ac ka installation hua h but temperature 16 kr rha hu 25 kr rha hu koi farq ni h ek hi jaisa coolness aa rha..aisa kyu? Aur installation ke time wo vaccum ka bi use ni Kiya tha technician ne
@@amitmondal3205 Agar aapke ac ki gas R32 hogi, aaj kal sabhi ac mein aa rahi hai, vacuum na karne ki vajah se bhi ye problem ho sakta hai. But pahle to aap check karo ki ac ki pipes jo outdoor unit ki aur ja rahi hai vo kahin se mudha hua to nhi hai. Aar ha to technician bula kar theek karwa lo. Nhi to company mein complaint karo ki install time pe vacuum nhi kiya. Dobara gas charging hogi, vacuum ke saath. Sab kuch free of cost hona chahiye. Vaise room chilled to ho raha hai na? temp meter se check kiya ki ac set temp pe room ko la raha hai ya nhi?
@@Clarkdale44 temperature check ni kiya but chill ho rha h room...but jo designated temp h ac me us hisab se ni ho rha like 20°C pe chl rha aisa feel ho rha...aur ha R32 hi h aur vaccum ni hua h to possible cause kya ho skta h iska? Maine call Kiya tha company walo ko wo bol rhe the gas leak ho skta...is it true?
@@amitmondal3205 Bina temp check kare batana mushkil hai, vacuum nhi kiya hoga to gas se air ko purge kiya hoga, ho sakta hai gas zyada nikal gayi ho. Aap outdoor unit pe jake mota and patla dono pipes ko chu ke check karna. Ac chalene ke 10 min baad test karna ki mote wala pipe chilled hona chahiye and uske upar pani hona chahiye. Patla wala bhi chilled hoga but mote wale se kam hoga. Ac ke samne temp meter se check karna agar temp 5-12 ke beech mein aa raha hai to machine ok hai.
Maine aaj ac install karaya to cooling nahi Hui....install karne wale na kaha ki R32 gas missing h, fir uske baad service Wale se baat karke bola ki kal dalunga gas....to kya ac lena chaiye ya waapis kardu??
JUST INFORMATION ONLY.....DON'T USE THREAD TAPES [ I MEAN TEFLON] IN COPPER LINES, IT CAUSES TO BLOCK INSIDE THE COPPER LINES. I DON'T KNOW WHY TECHNICIANS USE THREAD TAPES IN COPPER JOINT AREA?
Bhai... mera LG ka 1Ton ac hai.. aaj on kya tha 6months ke baad.. pehle 1hr attche se chal gaya..now outdoor unit ka fan nahi ghum raha hai..but indoor unit se hawa aa raha hai..kya problem hai
These are 3rd party installers ....all the companies do it and they don't have proper drilling tools i have a panasonic and lg Ac both did with 3rd party installers and hammer drill to make big holes
2:29 that process is so wrong. The pipe joint should never be bent. Instead, hole needs to be made on left side, pipe should be put from that hole, and indoor unit joint fittings should be made behind the unit.
Sir mere technician ne indoor se out door tak 2.5 sqmm ki new wire dali hai phele wali wire joint se jal gayi thi 1.5 sqmm ki thi company ki taraf se..toh 2.5 sqmm ki wire sahi hai ac ke liye???..1.5 ton ka Ac hai..plizz bataye
@@PS-bz2wi abhi one month hone ko hai abhi tak toh sahi chal rha hai Ac wire jali thi tab ac ka out door unit band ho gaya tha error code likha arha tha E6 technician ne wire check karke new daal di bola bar bar joint jalega toh ac ki pcb jal jayegi jho ki mhengi aati hai lekin abhi mera ac 4 saal ki pcb warranty mein hai l..Ek joint chalta hai company ki wire se out door unit tak 2 bhi chalate hai lekin joint achese se tape lagi honi chaiye water nahi jana chaiye rain ka..maine ish bar indoor se outdoor tak bina joint ki wire lagwayi hai..
An inverter AC has a variable speed compressor, while a non-inverter AC has a fixed speed compressor. Variable speed compressors are more energy efficient than their fixed counterparts and make less noise as well. That is the reason Inverter ACs are a bit expensive.
Very slow & wrong installation ! Dekh ke Lag raha hai ki AC ke drain outlet me problem aayegi. And Outdoor to indoor unit connect karne wali cable bhi copper pipe ke saath tape karni hoti hai warna 🐀 kaat denge to short-circuit ho jayega Also Outdoor unit in direct sunlight will consume more power because heat affects compressor performance so make shed for it
Amar same AC installation charges Rs.2714/- niyeche. Aaj e install korlo. Ami jani onek besi niyeche. Tar opor amk 3 pin r white cement kine niye aste hyeche. Seta te Rs.120/- . Total Rs.2834/- legeche.
Bhai jyda nhi 7 saal bad garmi itna hoga ki ac bhi fat jayega load nhi le payega kyuki ac bhi 45 degree se jyda pe kaam kam karta h or jab tem abhi se India m 55 cross kar rha h ki bahar niklna muskil ho jayega isliye ped jaruri hai nhi to Marne ke liye ready raho ac bhi nhi kaam ayega jab tem high ho jayega garmi se power plant kharab ho jayega to line bhi nhi rahega sab pta h sabko ki ped kitna jaruri hai lekin bewkuf bnana h kyuki abhi ac se se apna Kam chal ja rha h par kab tak
Yesterday memu onida 1.5 ton 3 star inverter ac biginchamu.. Ac install chese vellu ok.. Parledhu. Bagane bigincharu.... 😍 ac konalani 4 years ga anukuntunnam.. Finally happy
Use core cutting instead of drilling walls which gives u neat installation.
12 by 13 room
Which and how many ton ac required
Ac is good or cooler both option I can use which one is better
we installed lloyd AC 1.5 ton 3 star 1 year ago in my home. Still in very good service and condition.
No issue!
But my preference is always LG 5 star but LG AC are way more costly.
Yes...
Correct 💯
Panasonic aur voltas kaisa hain3 star
@@jaibalodi4344 acha hai
@@jaibalodi4344Panasonic is best for home.. I am using Panasonic matter enabled smart ac.. heavy duty and very fast cooling.. however Daikin is also good.. but missing convertible modes.. Daikin and Panasonic both are example of Japanese engineering 🔥 and the best commercial purpose acs are Mitsubishi and general.. these are too much costly..
How is the Ac running now? After the delivery of the ac , how many days does it take for the installation guy to come and install it? And for that hole I guess the Core cutting drill would have been nicer!
Running good,, after 2-3 Days
Outdoor unit stand ta apni market theke purchase korechen na service engineer theke ?
Show Room r theke..
Wall me hole karne k alag charges liye the ya installation charges me included hota hai ?
Nahi,, this is part of installation
Hi sir , 2nd from top floor me laga sakta hai na AC?
Hmmm
Installation karne mein kitna time lagta hai
@@ankitkumargupta424
1-2 house
@@SenTechnical thank you
❤🎉😊
❤😊🎉
Hi@@SenTechnical
Outdoor k pipe par tap ki insulation honi chaye? Main ny jis sy install karaaya os ny tap nai lagai pipe par. Bolta k ap ka outdoor par dhoop nai parti es liye koe issue nai
Khub vlo 😊video
@@SuvoRoy001 Thank you.
Sir ji Mera Haier Ac 1.6ton ka h jabse vgourd ka stablizer lagaya hun tab se input 150 k niche aur output 220 ki niche rehne se Ac bahut acha cooling deta h aur agar input 160 170 se upar aur output 230 ya 240 k upar rehne se cooling dena band kar deta hai So isme Ac ka problem h ya stablizer ka
Call service center
Bro vaccum process duration???
@@praveenm6773 15-20 m
Congratulations ❤❤❤❤❤
Theek installation hua hai, but vacuum ke time bahut badi gadbadi kar di technician ne. Gas release karne se pahle vacuum pump ka pipe nhi nikalna chahiye. Otherwise air phir se ander chali jati hai. Joki aapke case mein hua hoga.
Proper process ye hai, vacuum pump chalao, complete hone pe pahle manifold gauge ka valve band karo, phir vacuum pump band karo, 10 min wait karo, if manifold ki sui still rahti hai then compressor se thoda sa gas release karo, soap water se leakage check karo, if no leaking, then poora gas release kar do, only after this vacuum pump ko pipe machine se nikalo. Eysa karne se gas ka pressure air ko andar nhi aane deta.
Mujhe itna knowledge Nehi tha,,
Mere ghr me kch din pehle hi ac ka installation hua h but temperature 16 kr rha hu 25 kr rha hu koi farq ni h ek hi jaisa coolness aa rha..aisa kyu? Aur installation ke time wo vaccum ka bi use ni Kiya tha technician ne
@@amitmondal3205 Agar aapke ac ki gas R32 hogi, aaj kal sabhi ac mein aa rahi hai, vacuum na karne ki vajah se bhi ye problem ho sakta hai. But pahle to aap check karo ki ac ki pipes jo outdoor unit ki aur ja rahi hai vo kahin se mudha hua to nhi hai. Aar ha to technician bula kar theek karwa lo. Nhi to company mein complaint karo ki install time pe vacuum nhi kiya. Dobara gas charging hogi, vacuum ke saath. Sab kuch free of cost hona chahiye.
Vaise room chilled to ho raha hai na? temp meter se check kiya ki ac set temp pe room ko la raha hai ya nhi?
@@Clarkdale44 temperature check ni kiya but chill ho rha h room...but jo designated temp h ac me us hisab se ni ho rha like 20°C pe chl rha aisa feel ho rha...aur ha R32 hi h aur vaccum ni hua h to possible cause kya ho skta h iska? Maine call Kiya tha company walo ko wo bol rhe the gas leak ho skta...is it true?
@@amitmondal3205 Bina temp check kare batana mushkil hai, vacuum nhi kiya hoga to gas se air ko purge kiya hoga, ho sakta hai gas zyada nikal gayi ho. Aap outdoor unit pe jake mota and patla dono pipes ko chu ke check karna. Ac chalene ke 10 min baad test karna ki mote wala pipe chilled hona chahiye and uske upar pani hona chahiye. Patla wala bhi chilled hoga but mote wale se kam hoga.
Ac ke samne temp meter se check karna agar temp 5-12 ke beech mein aa raha hai to machine ok hai.
Apnar lloyd ac keno choice holo dada aktu janaben dada review ta . ami akta ac brand khujh chilam tai dada kunta nibo confused a pore gechi dada
Ami niychi,, amr friend r same brand niyche tai,, Tumi carrier a jete paro valo brand
Bhai meri tareh aapko LLOYD pasand hai
Compressor tao to vacuum korte hobe, tai nay ki Dada?
Ha kintu onek technician kaj komanor jonno vaccum na kore chole jay tar por cooling issue hay😊
Vacuum must
@@amatureexplorer akdom ac installation er somoy nojor rakhte hoi noyto onek somoy technician ra vaccum na kore chole jay
price kya hai eska total kitna lga with installation
End of this video
@@SenTechnical 22 AC ka price pucha hai wo to maine dekh liya hai
Bol6ilam dada ac plg point ki sob somli right side ai korte hoi , amara take sei bujhe plug point ta korbo ☹️, aktu bolle valo hoto
Right side a koro,, ac option thake change kora jai..
@@SenTechnical amader left side a korlee valo hoto ☹️ left side a korlee problem hove kichu ☹️
Water pipe ki include thake naki oder theke buy korte hoy?
2 fit moton thake,, aro lagle oder theke kinte hobe
Bhai aapne jo Ac lagaya hain woh mobile se connect hota hain???
Nahi
How is the cooling now?
@@lifefundadosto1255 Good
World ka no. 1 ac
Instalation fees ?
End of the video
Incomplete bari ta complete hole?? r apnar barir floor barle ki korben dada??
Hmmm
Kitna charges lagta hai installation me
You see the bill,end of this video
@@SenTechnical isse Kam me to bahar se karwa sakte hai aur company se acha bevkuf banate hai company wale
Installation er somoy kiser jonno koto khoroch holo ?
Sir apnar ACr woal kating taa right sidea kore nater jointaa out sidea koreche jokhon paser barir woal taa barabe tokhon oii natta ar nebe kau khulte parbena atai boro install porblemb hoyageche ar badbaki motamoti ok
Acha,,, Okay,, dekha jak pore ki hoy..
AC shifting Nahin Ho payega Wrong side se unhen nikala hai Jab Baju wala Ghar Ban Jaega tab Union Kaise khologe
Matlab kyon sa brand ka lena chahiye
N@@jaibalodi4344
Dada 1st din to aktu time legechilo room ta thanda hote??
Na ,, 12-15 minute a motamuti thanda hoye jai
Maine aaj ac install karaya to cooling nahi Hui....install karne wale na kaha ki R32 gas missing h, fir uske baad service Wale se baat karke bola ki kal dalunga gas....to kya ac lena chaiye ya waapis kardu??
Hosake to kardo,,,
bro i bought same ac from amazon but didnt get any filter in box or in ac what to do ?
U get scammed(ФωФ)
Hitachi ka ac acha hai kya ?
Pata nahi
Daikin best
Bhai charges toh nki 2700 bolo amy ei same model great Eastern theke nilm
Ekono installation hoini
@@smartinvest8400 install korar pore oder samne 30 min chalabe,,, sob kichu ok hole then oder OTP (phone sms asbe installation r )debe,,
Installation charges?
End of this video
Ami AC installation er 1500 nise but kuno cash memo dilo na.. Assam
@@RezaulKarim-u9w cash memo nile valo hoto...
JUST INFORMATION ONLY.....DON'T USE THREAD TAPES [ I MEAN TEFLON] IN COPPER LINES, IT CAUSES TO BLOCK INSIDE THE COPPER LINES. I DON'T KNOW WHY TECHNICIANS USE THREAD TAPES IN COPPER JOINT AREA?
Pipe wrong side sa liya ha in future kabhey dishmantal sarvice kasa karanga
Kya installation karrha hai wiring ka btayahi nhi kisme kon wire lgega
Mera Ghar PE 2018 se lloyd ac he no problem
Nice 👍🏻
Installation free nahi hai kya new me. @@SenTechnical
@@Allinone-vq9ny No.
Vaccum er jonne alada taka nae?
@@nilyet হম নিয়েছে
Bhai... mera LG ka 1Ton ac hai.. aaj on kya tha 6months ke baad.. pehle 1hr attche se chal gaya..now outdoor unit ka fan nahi ghum raha hai..but indoor unit se hawa aa raha hai..kya problem hai
Call service center
Out of warranty hai... service centre ne visiting charge 1500 bola hai...parts kharab hoga to parts ka extra paisa lagela...bohut jyada bol raha hai
Complete disaster, unprofessional work done. Don't even have proper drilling round core tool for making proper hole in a wall.
Ye Bengali hain
These are 3rd party installers ....all the companies do it and they don't have proper drilling tools i have a panasonic and lg Ac both did with 3rd party installers and hammer drill to make big holes
Outdoor ko kabhi bhi ulta ni rakhna chahiye
bhai on krne baad instantly cool air kyu nhi aati, thodi der baad cool aati hai, is this common?
compressor start hone pe time lagta hai isliye
vaccum karke kya matlab hua jab line khulega fir se air pipe ke andar chale jayega
Nahi,, valb rehata hai..nahi jata
Cost sasta hai installation ka bro yaha 2000 upper hai...
Hum apne room me 3 ton ka ac use kar sakte hai
Stand ka kitna liya bhai
Ac ka price Kya h?
@@012s77 43k
2:29 that process is so wrong. The pipe joint should never be bent. Instead, hole needs to be made on left side, pipe should be put from that hole, and indoor unit joint fittings should be made behind the unit.
🎉🎉🎉🎉congrts🎉🎉🎉🎉🎉
Bhai Tumhara core vate nahin hai kya
Bhai loot liya tumhe
Serf muje Nehi..all the customer,, kuch kar Nehi sakte
hamare ghar par abhi jehi wala 2024 modal leke aye h abhi kal feeting krwani h
kitna Charges lga bhai Installation Ka
@@ashishtuhania
Kl same ac ki fitting krwayi company k through 10k fitting charges
@@nikkik3105wtf realy?
@@ashishtuhania installtion free a ji jo extra pipe lagi uska charges lga bs
Eta 2 ton er ac ?
Yes
Sir mere technician ne indoor se out door tak 2.5 sqmm ki new wire dali hai phele wali wire joint se jal gayi thi 1.5 sqmm ki thi company ki taraf se..toh 2.5 sqmm ki wire sahi hai ac ke liye???..1.5 ton ka Ac hai..plizz bataye
Chalega 2.5 sqmm but use 4 sqmm for more durable and safety
4 mm
joint se q jal gayi thi aur installation k kitne din baad jali thi?
@@PS-bz2wi 4 se 5 joint thai wire mein aur 2 saal baad jali thi wire
@@PS-bz2wi abhi one month hone ko hai abhi tak toh sahi chal rha hai Ac wire jali thi tab ac ka out door unit band ho gaya tha error code likha arha tha E6 technician ne wire check karke new daal di bola bar bar joint jalega toh ac ki pcb jal jayegi jho ki mhengi aati hai lekin abhi mera ac 4 saal ki pcb warranty mein hai l..Ek joint chalta hai company ki wire se out door unit tak 2 bhi chalate hai lekin joint achese se tape lagi honi chaiye water nahi jana chaiye rain ka..maine ish bar indoor se outdoor tak bina joint ki wire lagwayi hai..
Bhai m iska 1.5 ton 5star le raha kaisa rahega please batao
Acha hai...
WHATS THE PRICE OF AC???
@@MOMINUL03 43 k
Ye Kab Ka Model Hai
2024
Dada total koto taka nilo....
Dek last a bill picture diye6i
Kaku 1415 taka standard fee kothai niyechilo, please reply
আমার কাছে 1000টাকা স্ট্যান্ড এর নিয়েছে। টেপ r জন্য 750😢
@@babulsk8686 লুটে নিয়েছে দাদা আপনাকে🥴🥴
Assam ka youtuber lag rha hai
internal unit ki back plate ka kya size hai ?
Pata Nehi,,, Google karlo
কত খরচ হল....
installation charges jayada he Lloyd ka
Pehle outdoor ko sidhe rakhana sikho nahi unka oil nahi rahega itna ta maloom hona apko🤕🤕
Nice❤❤
Thank you 😊
Voltas me rubber pahle se milta hai 😂
Inverter or non inverter কি পার্থক্য একটু কেউ বলবেন
viewers কেউ জানলে... দিদিকে পার্থক্য বলে দাও....
An inverter AC has a variable speed compressor, while a non-inverter AC has a fixed speed compressor. Variable speed compressors are more energy efficient than their fixed counterparts and make less noise as well. That is the reason Inverter ACs are a bit expensive.
Lyod ye kon sa aac hai
Video me bataya hai
nice❤
Very slow & wrong installation ! Dekh ke Lag raha hai ki AC ke drain outlet me problem aayegi.
And Outdoor to indoor unit connect karne wali cable bhi copper pipe ke saath tape karni hoti hai warna 🐀 kaat denge to short-circuit ho jayega
Also Outdoor unit in direct sunlight will consume more power because heat affects compressor performance so make shed for it
Yes,, bro..
17:41 sach mein pipe ko ganda bhi kar diya. Jyada accha karne gaya tha.
Dada kemon sarvis dacha
Valo
Are Bhai core bit nhi h kya
12:23 mai itna gareeb hu ki mujhe ajj pata chala ki ye AC ka part hota hai 😂
Areeee bhai 😂😂
How to clean the filter
Water pipe ka paisa kaha ? Apne kharida tha kaya?
Nahi..
To fir apne indoor ka water pipe nahi lagaya?
@@supriyo3955 nahi
@@SenTechnical 😂 Bhai pipe lagana chahiye
I's ac me problem hardam Aya ga mere ac me aata hai
Yes
Helpful video
🤗
Tmk lute niyeche dada😂
Mera wall 15inch hai ami ki ac nite parbo ,
Akdom kintu besi pipe lagbe tarmane extra taka
Inhone outdoor section line discharge line pr likej to chek hi nhi kya thik se 2 3 bund Pani ki dal di bas abhii likej ho gya to kese pta chalega
Avi Tak to cooling horahahi
Amar same AC installation charges Rs.2714/- niyeche. Aaj e install korlo. Ami jani onek besi niyeche. Tar opor amk 3 pin r white cement kine niye aste hyeche. Seta te Rs.120/- . Total Rs.2834/- legeche.
Kichu korar nei diye hobe
Are bahi thaga gye ji me khud ek ac engineer hu ye vakum charge ye ruber charge ye sb kuch nhi hota h 😊
You're bengali
Hmmm
DADA Daikin ac valo hobea
@@VIRATKOHOLI2.0 Valo
Thanks dada
Ac nhi ped lagao bhai
Tu lga le bhai ped jiske pas pasie hai wo toh AC lagayange hi 🤣
Bhai jyda nhi 7 saal bad garmi itna hoga ki ac bhi fat jayega load nhi le payega kyuki ac bhi 45 degree se jyda pe kaam kam karta h or jab tem abhi se India m 55 cross kar rha h ki bahar niklna muskil ho jayega isliye ped jaruri hai nhi to Marne ke liye ready raho ac bhi nhi kaam ayega jab tem high ho jayega garmi se power plant kharab ho jayega to line bhi nhi rahega sab pta h sabko ki ped kitna jaruri hai lekin bewkuf bnana h kyuki abhi ac se se apna Kam chal ja rha h par kab tak
Mai apne Ghar k garden me 3 ped lagaye hai. R flower plant alag se.
Wekkuum pump se modified gage kyu nikal liya?
Tap ka Market price 45 -50 ke ass pas he
Tapping ka original price 50 rupees hee...🙂
Wall me hole karne ka alag tool aata h
1 ton lg ac kitna current leta hai
220 v
sir current puchha tha voltage nhi
current bataiye ampire me
lloyed ac on hone k bad red light q jalta hai??
Khape Red light...? Mera ac me Red light Nehi hai..
Left side indoor down
Don't use Teflon tap for new machine
Hlo bhai lloyd costmer care hi karya kya ac instal
Hmmm
Pipe pe tap karne ka koi charge nahi hota bhai lut liya usne
Kuch nehi kar sakte,, no option
पानी वाला पाइप कहा ac का जिसमें से ऐसी का पानी निकालता है?